Non-Corrosive Primers

Non-Corrosive Primers

NON-CORROSIVE PRIMERS

Offering our products we think that it's our duty to give you the following information: each shot of the non-corrosive primer educes many deleterious substances into the air. The products which are dangerous for men and educe with this and the volume of the pure air which is necessary for the limit permissible concentration are given in Table 1. For example, the shooting gallery with the inner volume of 4000 m3 (100x20x2) m exceeds the limit permissible concentration after 8-10 shots according to Russian standards. If the intensity of shooting in the shooting gallery is 300 shots/hour the limit permissible concentration will be 42 times as large and we'll need an exhaust ventilator with the powerof 168000 m3/hour.

It's practically impossible to support such air exchange. Besides the heavy metal vapours (lead) are the most dangerous for men and accumulate on the lower layer of the room and it's very difficult to remove them with the help of ventilation.

Table 1

Non-corrosive primers / Lead / Sulphur dioxide / Barium oxide / Antimony oxide / Carbon oxide
The weight of products educes with one shot, mg / 5 / 1,2 / 5 / 2 / 80
The limit permissible concentration of the air according to Russian norms, mg/m3 / 0,01 / 0,5 / 0,1 / 0,5 / 30
The volume of the pure air which is necessary for permissible concentration, m3 / 500 / 2,4 / 50 / 4 / 2,7

HEAVY METAL FREE PRIMERS

We think that the most significant achievement for us is expelling heavy metals from their combustion products.

Attention: these primers (in comparison with simple non-corrosive primers) have letter «E» and a green colour package.

These primers, as we see from the table 2, don't educe the most dangerous for men substances: lead, sulphur dioxide, barium oxide and antimony oxide when shooting.

The air pollution will be one-one thousand two hundredth of it's previous value when using potassium carbonate, carbon monooxide.

Besides to remove it's excess in the shooting gallery with the volume of 4 000 m3 we need the ventilator of the power of 840 m3/hour.

Table 2

Heavy metal free primers / Lead / Sulphur dioxide / Barium oxide / Antimony oxide / Potash / Carbon oxide
The weight of products educes with one shot, mg / - / - / - / - / 1 / 80
The limit permissible concentration of the air according to Russian norms, mg/m3 / - / - / - / - / 5 / 30
The volume of the pure air which is necessary ' for permissible concentration, m3 / - / - / - / - / 0,2 / 2,7