April 2016

Neurosurgical Prostheses Grouping Scheme and Benefits

**Suffixes legend and definitions are located at the end of this document

Groupings / Benefits /
04 - Neurosurgical
04.01 - ANEURYSM CLIPS
04.01.01 - Aneurysm Clip
258
Complex / 378
04.01.02 - AVM Clip
270
04.02 - DURA DEFECT REPAIR
04.02.01 - Repair, Graft, Small (≤10cm²)
72
Biological / 360
04.02.02 - Repair, Graft, Medium (>10 to 50cm²)
472
Biological / 545
04.02.03 - Repair, Graft, Large (>50 to 100cm²)
785
Biological / 1120
04.02.04 - Repair, Graft, Extra Large (>100cm²)
655
Biological / 1890
04.02.05 - Repair, Liquid Sealant (0 to 3ml)
800
04.02.06 - Repair, Liquid Sealant (>3 to 6ml)
835
04.02.07 - Repair, Self-Adhesive Membrane Sealant, Small (≤10cm²)
250
04.02.08 - Repair, Self-Adhesive Membrane Sealant, Medium (>10 to 50cm²)
560
04.02.09 - Repair, Self-Adhesive Membrane Sealant, Large (>50 to 100cm²)
1020
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.01 - Valve, Externally Adjustable
2020
Antisyphon function, Coating, Distal catheter, Proximal 3310
catheter, Reservoir/Priming function
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.01 - Valve, Externally Adjustable
Antisyphon function, Coating, Distal catheter, / 3165
Reservoir/Priming function
Antisyphon function, Coating, Reservoir/Priming function 2980
Antisyphon function, Distal catheter, Proximal catheter, 3200
Reservoir/Priming function
Antisyphon function, Distal catheter, Reservoir/Priming 3055
Antisyphon function, Reservoir/Priming function / 2870
Distal catheter, Lumboperitoneal, Proximal catheter, 3030
Reservoir/Priming function
Distal catheter, Proximal catheter, Reservoir/Priming function 2700
Distal catheter, Reservoir/Priming function / 2555
Lumboperitoneal, Reservoir/Priming function / 2700
Reservoir/Priming function / 2370
04.03.01.02 - Valve, Non-externally adjustable
1110
Antibiotics, Antisyphon function, Distal catheter, Proximal 2180
catheter, Reservoir/Priming function
Antibiotics, Distal catheter, Proximal catheter / 1740
Antibiotics, Distal catheter, Proximal catheter, / 2090
Reservoir/Priming function
Antisyphon function / 1200
Antisyphon function, Coating, Distal catheter, Proximal 1990
catheter, Reservoir/Priming function
Antisyphon function, Coating, Distal catheter, / 1845
Reservoir/Priming function
Antisyphon function, Coating, Reservoir/Priming function 1660
Antisyphon function, Distal catheter, Proximal catheter, 1880
Reservoir/Priming function
Antisyphon function, Distal catheter, Reservoir/Priming 1735
Antisyphon function, Lumboperitoneal / 1530
Antisyphon function, Reservoir/Priming function / 1550
Distal catheter, Lumboperitoneal / 1625
Distal catheter, Proximal catheter / 1440
Distal catheter, Proximal catheter, Reservoir/Priming function 1790
Distal catheter, Reservoir/Priming function / 1645
Lumboperitoneal / 1440
Reservoir/Priming function / 1460
04.03.01.03 - Valve and gravitational unit, externally adjustable
4040
Distal Catheter / 4225
04.03 - HYDROCEPHALUS DEVICES
04.03.01 - Valves
04.03.01.03 - Valve and gravitational unit, externally adjustable
Distal Catheter, Reservoir/Priming Function / 4575
04.03.02 - Unitised shunt assembly, with proximal/distal catheter
450
Antisyphon function / 1650
Reservoir/Priming function / 900
04.03.03 - Catheter
Antibiotics / 469
Antibiotics, Distal, Proximal / 675
Distal / 185
Distal, Coating / 255
Proximal / 185
Proximal, Coating / 249
04.03.04 - Antisyphon Device
880
04.03.05 - Reservoir/Priming Device
375
Integrated Catheter / 560
04.03.06 - Shunt Attachment
04.03.06.01 - Connector
38
04.03.06.02 - Right Angled Guide
200
04.04 - DEEP BRAIN STIMULATION (DBS)
04.04.01 - Implantable Pulse Generator
04.04.01.01 - Primary Cell Pulse Generator (non-rechargeable)
9050
Dual Channel / 15060
04.04.01.02 - Rechargeable Pulse Generator
Dual Channel / 19150
Unlimited Deep Discharge Battery / 22000
04.04.02 - External Components
04.04.02.01 - Patient Programmer
1400
04.04.02.02 - Recharger
1975
04.04.03 - Leads
04.04.03.01 - Permanent Lead
04.04 - DEEP BRAIN STIMULATION (DBS)
04.04.03 - Leads
04.04.03.01 - Permanent Lead
4150
04.04.03.02 - Lead Extension
2100
04.04.04 - Microtargetting Electrodes
1500
04.04.05 - Accessories
04.04.05.01 - Burr Hole Cover
550
04.04.05.02 - Connectors and cables
200
04.04.05.03 - Intraoperative accessories
175
04.05 - NEUROSTIMULATION THERAPIES FOR PAIN MANAGEMENT
04.05.01 - Pulse Generators
19150
04.05.01.01 - Primary Cell Pulse Generator (non-rechargeable)
19150
Multi waveforms / 24000
04.05.01.02 - Rechargeable Pulse Generator
19150
Adaptive Stimulation / 24000
Adaptive Stimulation, Unlimited Deep Discharge Battery, 32 26000
Electrode IPG
Integrated Leads / 19980
Unlimited Deep Discharge Battery / 22000
Unlimited Deep Discharge Battery, 10kHz Stimulation 26000
04.05.01.03 - Radio Frequency System
9450
Dual Channel / 12450
04.05.02 - External Components
04.05.02.01 - Patient Programmer
1500
04.05.02.02 - Patient Programmer Antenna
178
04.05.02.03 - On/Off switching device
1346
04.05.02.04 - Recharger
1346
04.05.03 - Leads
04.05.03.01 - Permanent Lead
04.05 - NEUROSTIMULATION THERAPIES FOR PAIN MANAGEMENT
04.05.03 - Leads
04.05.03.01 - Permanent Lead
≥32 electrodes / 12200
>8 and <32 electrodes / 7640
4 electrodes / 3400
8 electrodes / 4230
04.05.03.02 - Trial Lead
485
04.05.04 - Lead Extension
1510
04.05.05 - Accessories
04.05.05.01 - Revision Kits
545
04.05.05.02 - Plug
168
04.05.05.03 - Intraoperative Accessories
168
04.05.05.04 - Lead Delivery System
730
04.05.05.05 - Connectors and Cables
200
04.06 - INTRATHECAL DRUG DELIVERY SYSTEM
04.06.01 - Implantable Infusion Pump
Fixed Flow Rate / 9300
Variable Flow Rate / 16250
04.06.02 - Patient Programmer
1500
04.06.03 - Intrathecal Catheter
04.06.03.01 - One piece
500
04.06.03.02 - Two piece
1100
Reinforced / 1100
04.06.04 - Accessories
04.06.04.01 - Revision Kit
600
04.06.04.02 - Refill/Catheter Access Kits
40
04.07 - NEUROSTIMULATION THERAPIES FOR SEIZURE CONTROL
04.07.01 - Vagal nerve stimulators
04.07.01.01 - Implantable pulse generator
04.07 - NEUROSTIMULATION THERAPIES FOR SEIZURE CONTROL
04.07.01 - Vagal nerve stimulators
04.07.01.01 - Implantable pulse generator
12670
04.07.01.02 - Lead
3400
04.08 - NEURO INTERVENTION
04.08.01 - Stent
7500
04.08.02 - Coils
1505
04.08.03 - Assist Devices
04.08.03.01 - Catheters
700
04.08.03.02 - Coil detachment device
350
04.08.03.03 - Guidewire
680
04.08.03.04 - Vascular embolisation balloon
1727
04.08.04 - Intrasaccular flow diverter
9030
04.09 - Intracranial Pressure (ICP) Monitoring
04.09.01 - Transducer
Catheter / 1300
Skull Bolt / 1050
04.10 - Cerebrospinal Fluid (CSF) Diversion
04.10.01 - External Ventricular Drain
185
04.10.02 - External Lumbar Drainage
300

Suffixes:

DE: Device electronically receives and stores intermittent or continuous glucose information from an external or integral/attached device

RT: System can transmit real-time data or alerts to third party devices or systems (eg. digital telephone network or internet)

SS: System includes software which allows downloading and analysis of information

OTS: Over the Scope

Definitions:

Absorbable Oil Coating Coating which minimises tissue attachment and foreign body reaction and inflammation

Absorbable Capable of being absorbed

Abutment Connection between the sound processor and implant (fixture)

Adaptive Stimulation Senses patient body position and adjusts stimulation accordingly

Adhesion Prevention Product minimises the likelihood of adhesions

Anatomically Conforming Conforms to body shape

Angled/Offset The Angled/offset abutment is used to compensate for the angle of the implant when inserted into the jaw

Antibiotic Contains or is covered with an antibiotic to prevent infection

Antimicrobial Substance that kills or inhibits the growth of micro-organisms

Antisyphon function Prevents unwanted drainage or transfer of a liquid

Articulating/Roticulating Having joints or jointed segments and able to rotate the head of the device around the central axis

Assembly A product made up of multiple components

Biological Made from tissue harvested from animals or human cadavers

Biomodelled Patient specific prosthesis usually manufactured using 3 dimensional scans and manufacturing technology

Bioresorbable Item breaks down and is absorbed/resorbed by the body and expelled through one of the body's systems

Bolus A large volume of fluid or drug dose given intravenously and rapidly at one time

Burr Burr hole covering plate

Coated A coating that minimises the likelihood of adhesions

Coating A coating that minimises the likelihood of adhesions

Complex Composed of many interconnected parts

Compression Device features intrinsic capacity to apply compression force

Connectors and Cables Single use products integral to connecting components of neurostimulation systems

Deep Discharge Battery Allows frequent discharge to zero volts without causing early battery failure

Delivery System A means or technology or device for administering drug or treatment

Distractor Surgical instrument or apparatus used for bone development

Doppler Guided Use of a doppler to identify veins during a surgical procedure

Dual Channel A system with the ability to simultaneously deliver two different levels of stimulation

Dual Mesh Combination of absorbable and non-absorbalbe fibres

Dual Plate Consisting of more that one plate

Electroacoustic Use of a hearing aid and Cochlear Implant together. The hearing aid acoustically magnifies low frequencies, whilst the Cochlear electronically stimulates middle and high frequencies

Endoscopic A general term for minimally invasive surgery (MIS) or, specifically, MIS where the device is inserted via a natural body opening

Expander Implant Implant which is able to be expanded

Extra-tracheal Outside the trachea

Fixation Plate A plate used to stabilise fractures

Fixed Flow Rate The drug delivery flow rate is fixed at manufacture and is non-adjustable

Fixture Bone anchored implant

Flanged Having an external or internal ridge

Generation 3 Technological advance of the product

Generation 4 Technological advance of the product

Hemimandible Half of the mandible

Integrated Delivery System The implantable device is provided pre-loaded into the related delivery system

Intraoperative accessories Single use products integral to implanting a device

Intra-tracheal Inside the trachea

Laparoscopic Extender A device designed to provide an extension of reach duirng laparoscopic surgery

Laparoscopic Minimally invasive surgery where the device is inserted via a trocar through a surgical incision (key hole surgery)

Locking Ability to lock the plate as the screws are tightened

Maxilla The upper jaw

Multiple Chamber Consisting of at least two compartments

Multivector Modular system that can be adapted to achieve a wide range of clinical results

Nitinol Made from nickel titanium alloy

On/Off switching device A device provided to the patient to switch the pulse generator on and off

Patient Programmer A device provided to the patient to self-modulate a drug delivery or impulse generator system

Polymer Comprises of polyethylene

Pre-shaped Having a predetermined width, height and projection

Programmable Able to be programmed

Reinforced Wall reinforcement to improve strength, durability and resist kinking

Resorbable Can be broken down and assimilated back into the body

Resorbable Item breaks down and is absorbed/resorbed by the body and expelled through one of the body's systems

Revision kit Single use products integral to revising an implanted system

Self Expanding Auto inflating using osmosis

Self Expanding Compressed stents which expands automatically

Self-fixating Enables positioning and secure placement without the need for sutures

Silicone A synthetic compound

Single Vector A subcutaneous ramus lengthening distractor

Symphsis Intermandibular joint

Synthetic A substance or material produced by chemical processes and not occurring naturally

Textured Coating having different types of irregularities or rugasity

Valved Having a valve

Variable Flow Rate The drug delivery flow rate is able to be adjusted dependent on clinician preferences and patient needs