MDM490 Differential Pressure Transmitter

MDM490 Differential Pressure Transmitter

Applications

MDM490 transmitters is used for measuring various gases & liquids

Differential pressure in the fields of petroleum, chemi-industry,

power station and hydrology etc.

Features

Full stainless steel construction, compact size, light and easy

for installation

Laser-welded,full-sealedconstruction, housingprotection:IP65

Silicon piezo-resistive differential pressure sensor,

316L stainless steel isolated diaphragm, Compact size,

Temperature compensation and long-term ageing selection, High-stability

Zero & Span can be adjustable externally

Intrinsically safe version Exia II CT6 conform with Standard GB3836.4, Certificate No. CNEx06.0806

Ship-use version available, Certificate No.TJT02230014

Specification

RANGE CODE / 01 / 02 / 03 / 04 / 05 / 06 / 07 / 08
UNIT / kPa / MPa
RANGE / 0~10 / 0~20 / 0~50 / 0~100 / 0~200 / 0~0.5 / 0~1.0 / 0~2.0
OVERPRESSURE / 250 / 250 / 250 / 300 / 400 / 1.0 / 2.0 / 4.0
NEG. VERPRESSURE / 100 / 100 / 100 / 200 / 300 / 0.5 / 0.7 / 1.0
STATIC PRESSURE / ≤20MPa
Min. / TYP. / MAX. / UNIT
ACCURACY (L+H+R) / LIN.+HSY.+REP.
0~100kPa / ±0.25 / ±0.5 / FS%
200~2000kPa / ±0.1 / ±0.25 / ±0.5 / FS%
TEMPERATURE
ZERO ERROR
0~100kPa / ±0.75 / ±1.25 / FS%,Refer to 25℃
200~2000kPa / ±0.5 / ±0.75 / FS%,Refer to 25℃
FS ERROR
0~100kPa / ±0.75 / ±1.25 / FS%,Refer to 25℃
200~2000kPa / ±0.5 / ±0.75 / FS%,Refer to 25℃
STATIC EFFECT / ±0.05 / FS%,EACH 100kPa
COMP. TEMP. RANGE / 0~50 / ℃
OPERATION TEMP. RANGE / -10~80 / ℃
STORAGE TEMP. RANGE / -40~120 / ℃
LONG TERM STABILITY
≤200kPa / ±0.5 / FS%
≤2000kPa / ±0.2 / FS%
ELECTRICAL CHARACTERISTIC
SUPPLY / 15~30VDC, 2-wire / 15~28VDC, 3-wire
OUTPUT / 4~20mADC, 2-wire / 0/1~5/10VDC,0~10/20mADC, 3-wire
ELECTRONIC CONNECTION / Plug or Φ7.2mm 7-wires cable
RESPONSE(10%~90%) / ≤1ms
INSULATION / 100MΩ,50VDC
CONSTRUCTION MATERIAL
HOUSING / Stainless steel 1Cr18Ni9Ti
DIAPHRAGM / Stainless steel 316L
SEAL O-RING / Viton
FILL-IN / silicon oil
PRESSUREPORT / G1/4 Female
ENVIRONMENT
VIBRATION / @3gRMS 30~2000Hz, change≤1%
SHOCK / @100g,after 10ms, change≤1%
LIFE / 1×108 Circle
MEDIUM / Gas & liquid, which are compatibility with construction materials.

Constructionand Install Dimensions(unit: mm)

Plug Connection Cable Connection

Plug Connection Plug Form & Dimension (mm)

PIN / 2-wire / 3-wire
1
2
3 / + Vcc
0 Vcc / + Vcc
+OUT GND

Cable Connection

Colors / 2-wire / 3-wire
Black / +Vcc / + Vcc
Red / 0Vcc / +OUT
White / GND

OrderGuide

MDM490 / Differential Pressure Transmitter
Range Code / Range X[0~X] / Overpressure
Positive / Negative
01 / [0~10kPa] / 250 / 100
02 / [0~20kPa] / 250 / 100
03 / [0~50kPa] / 250 / 100
04 / [0~100kPa] / 300 / 200
05 / [0~200kPa] / 400 / 300
06 / [0~500kPa] / 100 / 500
07 / [0~1000kPa] / 2000 / 700
08 / [0~2000kPa] / 4000 / 1000
Code / Output
E / 4~20mADC
F / 1~5VDC
J / 0~5VDC
Q / 0~10mADC
U / 0~20mADC
V / 0~10VDC
Code / Construction Materials
Diaphragm / PressurePort / Housing
22 / 316L SS / SS / SS
25 / Tantalum / SS / SS
Code / Additional functions
C4 / Pressure port G1/4 femal
B1 / Plug connection
B2 / Cable connection 1.5m length
M3 / 3 1/2 LCD digital indicator (Only for 4~20mADC output)
M4 / 3 1/2 LED digital indicator (Only for 4~20mADC output)
i / Intrinsically safe version ExiaIICT6
T / Ship-use version
MDM490 / 03[0~30kPa] / E / 22 / C4B2

Notes:
1. For operation safe, must be use a tri-valve to connect with leading tube.
2. To suggest installation the two pressure ports in horizontal, to get best result.
3. To be care the static pressure ≤20MPa , range and overpressure of MDM490 shall be within the specification.

4. Other demands, please contact us and mark in the order.

1