/ 585 Charest Blvd. East, Suite 300
Québec, Québec G1K 9H4, Canada
Phone (418) 877–2944
Fax (418) 877-2834 or (418) 266–1422

Dernière révision du modèle de document PSR: 15 janvier 2003

ARIES

ARIES Airborne Radiometer Evaluation System

ARIES End Item Data Package

Document Number: / BOM-ARIES-0006 / Issue Date: / 7November2006
Issue: / 1 / Revision: / –
Distribution: / See page iv / Classification: / N/A
Function / Name / Signature / Date
Prepared by / Electronics Designer / Jean-Yves Trottier
Checked by / Electronics Lead / Mario Lehoux
Approved by / Project Manager / Robert Poulin

PROPRIETARY

The information contained herein is proprietary to and should be considered a trade secret of ABBBomem Inc. It shall not be reproduced in whole or in part without the written authorization of ABBBomem Inc.

3BOM000034D0010 rev C

PR-2100-FO

ABB / ARIES
ARIES End Item Data Package / Document No:BOM-ARIES-0006
Issue: 1Rev:–Page
Date: 7November20061

Table of Contents

1.Introduction......

1.1Purpose of Document......

1.2Scope

1.3Bibliography

1.3.1Applicable Documents

1.3.2References......

1.4Acronyms......

1.5Definitions......

2.Electrical Modification......

2.1Power Supply Plate......

2.1.1Modification details......

2.1.2Mechanical Aspect......

2.1.3Power Supply Plate Schematics......

2.2Optical Head......

2.2.1Modification details......

2.2.2Mechanical Aspect......

2.2.3Feedthrough......

2.2.4Optical Head Schematics......

2.3External Harnessing......

2.3.1Modification details......

2.3.2Mechanical Aspect......

2.3.3External Harnessing Schematics......

3.Material List......

List of Figures

Figure2–1...... Power Supply Unit Diagram

Figure2–2...... Fuse Enclosure

Figure2–3...... Power Supply Unit Relay

Figure2–4...... Power Supply Unit PS1

Figure2–5...... Power Supply Unit PS2

Figure2–6...... Power Supply Unit PS3-4-5

Figure2–7...... AW50D/15-A Wiring

Figure2–8...... Interconnections Rework

Figure2–9...... Optical Head Diagram

Figure2–10...... Optical Head Thermal Control

Figure2–11...... IO Modules

Figure2–12...... Optical Head FTB

Figure2–13...... Bloc Diagram

Figure2–14...... ADC #1

Figure2–15...... ADC #2

Figure2–16...... Metrology

Figure2–17...... Scan Amplifier Drive

Figure2–18...... Scan Amplifier Power

Figure2–19...... Ethernet

Figure2–20...... Laser

Figure2–21...... Motor #1

Figure2–22...... Motor #2

Figure2–23...... Power & White Light

Figure2–24...... Quadrature

Figure2–25...... White Light

Figure2–26...... RS-232

Figure2–27...... RS-422

Figure2–28...... RS-485

Figure2–29...... Temperature Sensor & I.D. Tag

Figure2–30...... P103-P106 Harness

Figure2–31...... P104-P107 & P102-P105 Harness

List of Tables

Table2–1...... Feedthrough wiring

Table4–1...... Upgrade Material List

Document Change Record

Issue / Rev. / Date
(yy-mm-dd) / Prepared by / Change Description
1 / – / 06-11-09 / Jean-Yves Trottier / First release.

Distribution List

The following persons (or company) shall receive this document:

Project Team

Client

Other

ABB / ARIES
ARIES End Item Data Package / Document No:BOM-ARIES-0006
Issue: 1Rev:–Page
Date: 7November20061

1.Introduction

1.1Purpose of Document

This documentation package is a bundle of all the information used and generated forthe ARIES instrument upgrade of summer 2006.

The purpose of the upgrade was to renew electronic and software of the instrument using ABB Bomem actual technology.

1.2Scope

1.3Bibliography

1.3.1Applicable Documents

AD1

1.3.2References

Ref.1Author, Title (italic style), Edition, Press, Year

Ref.2R. N. Bracewell, The Fourier Transforms and Its Applications, Second Ed. Revised, McGraw-Hill Publishing Co., New-York, 474 p., 1986

1.4Acronyms

BSR/CPBeam Splitter-Recombiner/Compensator Plate

BBBlack Body

FFTFast Fourier Transform

FOVField of View

FWHMFull Width at Half Maximum

IGMInterferogram

ILSInstrument Line Shape

INTInterferometer

IRInfra Red

LOSLine Of Sight

MCTMercury Cadmium Telluride

NESRNoise Equivalent Spectral Radiance

OPDOptical Path Difference

RMSRoot Mean Squared

SNRSignal-to-Noise Ratio

SPCSpectrum

ZPDZero Path Difference

TBCTo Be Confirmed

TBDTo Be Determined

TBRTo Be Reviewed

1.5Definitions

Word:Word Definition

2.Electrical Modification

2.1Power Supply Plate

2.1.1Modification details

The Power Supply Plate modification consists of removing the CEM0302G (ARIES Power Cube Assembly) that is not used any more and to replace the Abbott power supply AM50T/5/15-A (PS2) by an Abbott AW50D/15-A. These modifications are required to fulfill power requirements of the new electronics.

2.1.2Mechanical Aspect

The new Abbott power supply is installed at the same location as the old one, as it is slightly smaller, new mounting holes have been drilled into the holding plate.

A terminal bloc (TB5) has been mounted where the CEM0302G box was located, this one serves to bridge the two outputs of the power supply in a bipolar output and to connect remote sense terminals.

2.1.3Power Supply Plate Schematics

2.1.3.1Updated original drawings

The following drawings are original 1994 schematics, hand updated to reflect actual modified system:

  • Power Supply Unit Diagram
  • Fuse Enclosure
  • Power Supply Unit Relay
  • Power Supply Unit PS1
  • Power Supply Unit PS2
  • Power Supply Unit PS3-4-5

See next page for:

Figure2–1Power Supply Unit Diagram

See next page for:

Figure2–2Fuse Enclosure

See next page for:

Figure2–3Power Supply Unit Relay

See next page for:

Figure2–4Power Supply Unit PS1

See next page for:

Figure2–5Power Supply Unit PS2

See next page for:

Figure2–6Power Supply Unit PS3-4-5

2.1.3.2New drawings (Power Supply Plate)

The following drawings are new schematics made especially for the upgrade:

  • AW50D/15-A Wiring
  • Interconnections Rework

See next page for:

Figure2–7AW50D/15-A Wiring

See next page for:

Figure2–8Interconnections Rework

2.2Optical Head

2.2.1Modification details

The Optical Head modification consists of removing the major part of the electronics in the instrument and associated computer:

  • SEC0400G Metrology board.
  • SEE0200G Power amplifier board.
  • SEK3100G Servo control board.
  • SEK3200G Communication board.
  • SEK3300G Fiber optic interface.
  • SEK3400G ADC board (2X)
  • SEQ3200G DSP96002 data crunch
  • SEQ3300G PC communication board
  • SEQ3400G 64MB dram extension board

And of replacing it with an actual electronic board set consisting of:

  • SEE0600G High power drive board
  • 0002-11-2-00002-01 Digital control module model -A
  • 0002-07-2-00001-01 Science module model - A (2X)
  • 0002-13-2-00001-01 Metrology module model - A
  • 0002-13-2-00001-01 Temp. sensor & I.D. tag module model - A

Also, the laser and its power supply are actualised to the following components:

  • AA000566-01 L28120AL3747 PS Laser DC 1450Vout 4.5mA
  • 05LHP900 Laser M.G. 4.5mA anode output

Because of the non availability of a compatible RS-485 link on the Digital Control Module, all I/O modules were replaced with their RS-232 counterpart.

  • D1132 Voltage input module 5V=>D1131
  • D1412 RTD 0.00385 100 input module=>D1411
  • D1452 (2X) Thermistor 2252 input module=>D1451

2.2.2Mechanical Aspect

To avoid modifying Optical Head chassis and lower the risk causing pressure leak, some mounting plates were used to adapt new boards to existing holes pattern. The description and schematic of these adapters can be found in MECHANICAL MODIFICATION section.

The laser substitution required a new bracket design as the new one is actually smaller. Once again, you will find related information in MECHANICAL MODIFICATION section.

2.2.3Feedthrough

This is the after upgrade Feedthrough assignation:

Table2–1Feedthrough wiring

A1 / ETHERNET TX+ / B1 / NC / C1 / RS-422 RX+
A2 / ETHERNET TX- / B2 / NC / C2 / RS-422 RX-
A3 / ETHERNET RX+ / B3 / NC / C3 / SHIELD (RS-422)
A4 / ETHERNET RX- / B4 / NC / C4 / RS-422 TX-
A5 / SHIELD (ETHERNET) / B5 / +28VL / C5 / RS-422 TX+
A6 / NC / B6 / 28VLRTN / C6 / RS485- (WATLOW)
A7 / NC / B7 / +24VM1 / C7 / RS485+ (WATLOW)
A8 / +15VIN1 / B8 / 24VM1RTN / C8 / SHIELD (RS-422)
A9 / 15VIN1RTN / B9 / +24VM2 / C9 / NETWBOOT
A10 / -15VIN1 / B10 / 24VM2RTN / C10 / OUTPUT FAN (+)
A11 / +15VIN2 / B11 / +12VT / C11 / OUTPUT FAN (-)
A12 / 15VIN2RTN / B12 / 12VTRTN / C12 / SHIELD
A13 / -15VIN2 / B13 / SHIELD / C13 / OUTPUT HEATER (-)
A14 / SHIELD / B14 / NC / C14 / OUTPUT HEATER (+)
A15 / NC / B15 / NC / C15 / SHIELD (WATLOW)

2.2.4Optical HeadSchematics

2.2.4.1Updated original drawings

The following drawings are original 1994 schematics, hand updated to reflect actual modified system:

  • Optical Head Diagram
  • Optical Head Thermal Control
  • IO Modules
  • Optical Head FTB

See next page for:

Figure2–9Optical Head Diagram

See next page for:

Figure2–10Optical Head Thermal Control

See next page for:

Figure2–11IO Modules

See next page for:

Figure2–12Optical Head FTB

2.2.4.2New drawings (Optical Head)

The following drawings are new schematics made especially for the upgrade:

  • Bloc Diagram
  • ADC #1
  • ADC #2
  • Metrology
  • Scan Amplifier Drive
  • Scan Amplifier Power
  • Ethernet
  • Laser
  • Motor #1
  • Motor #2
  • Power & White Light
  • Quadrature
  • White Light
  • RS-232
  • RS-422
  • RS-485
  • Temperature Sensor & I.D. Tag

See next page for:

Figure2–13Bloc Diagram

See next page for:

Figure2–14ADC #1

See next page for:

Figure2–15ADC #2

See next page for:

Figure2–16Metrology

See next page for:

Figure2–17Scan Amplifier Drive

See next page for:

Figure2–18Scan Amplifier Power

See next page for:

Figure2–19Ethernet

See next page for:

Figure2–20Laser

See next page for:

Figure2–21Motor #1

See next page for:

Figure2–22Motor #2

See next page for:

Figure2–23Power & White Light

See next page for:

Figure2–24Quadrature

See next page for:

Figure2–25White Light

See next page for:

Figure2–26RS-232

See next page for:

Figure2–27RS-422

See next page for:

Figure2–28RS-485

See next page for:

Figure2–29Temperature Sensor & I.D. Tag

2.3External Harnessing

2.3.1Modification details

All electrical modifications to external harnessing are listed and explained in the document “BOM-ARIES-0005 ARIES Electrical ICD”.

2.3.2Mechanical Aspect

A bracket is added to hold the new Ethernet connector J125 and the new RS-422 connector J124, see “MECHANICAL MODIFICATION” section for details.

The optical fibers previously used for data communication are completely removed from the system, only the two sealed connectors remain on the Optical Head module. These were plugged with an appropriate SMA cap.

2.3.3External HarnessingSchematics

2.3.3.1Updated original drawings

The following drawings are original 1994 schematics, hand updated to reflect actual modified system:

  • P103-P106 Harness
  • P104-P107 & P102-P105 Harness

See next page for:

Figure2–30P103-P106 Harness

See next page for:

Figure2–31P104-P107 & P102-P105 Harness

2.3.3.2New drawings (External Harnessing)

New schematics made especially for the upgrade are found in BOM-ARIES-0005 ARIES Electrical ICD.

3.Material List

Here is the list of items added to the instrument for the upgrade:

Table3–1Upgrade Material List

Description / ABB's P/N / QTY / Supplier / Vendor's P/N
Computers
Rhino D820 laptop 2000 MHz 15.4" WSXGA+ / AA003188-01 / 2 / EmperorLinux
WinXP / 2
Electronic parts
Military AC-DC power supply ±15V 1.67A / AA003128-01 / 1 / Martek Power / AW50D/15-A
Voltage input RS-232 module ±5V / AA003110-01 / 1 / D1131
Thermistor 2252 Ohms Input, RS-232 / D1451 / 2 / D1451
RTD .00385 100 Ohms Input, RS-232 / M1411 / 1 / D1411
L28120AL3747 PS Laser DC 1450Vout 4.5mA / AA000566-01 / 1 / 9-0027-0788-0-0
Laser M.G. 4.5mA anode output / 05LHP900 / 1 / 05LHP900
RJ45 in line metal receptacle IP67 / AA003187-01 / 1 / Mouser / RJF2PEM1G
Ethernet Plug Connector Green / AA000525-01 / 1 / RJF6MG
100ft CAT5 Xover Shield Ether Grey Cable / AA000886-01 / 2 / CBCC235263-100
Feed through 15 pins / 200B0066 / 1 / 030-092-0126
Electronic assemblies
Digital Control Module Model-A / 0002-11-2-00002-01 / 1 / Bomem / N/A
MRXS High Power Drive Board / SEE0600G / 1 / Bomem / N/A
MRXS EMI Box ADC Stick Ass'y / 0002-10-2-00012-01 / 2 / Bomem / N/A
MRXS Metrology Module Model-A / 0002-06-2-00001-02 / 1 / Bomem / N/A
Temp. Sensor & I.D. Tag Module Model-A / 0002-13-2-00001-01 / 1 / Bomem / N/A
Cables assemblies
ARIES Metrology Harness / 0008-18-2-00004-01 / 1 / Connexion Technic / N/A
ARIES Scan AMP Drive Harness / 0008-18-2-00002-01 / 1 / Connexion Technic / N/A
ARIES ADC #1 Harness / 0008-18-2-00001-01 / 1 / Connexion Technic / N/A
ARIES ADC #2 Harness / 0008-18-2-00003-01 / 1 / Connexion Technic / N/A
Military connectors
Circ.Conn Box MountRecept 4 Sockets / K2E84S / 1 / PEI-Genesis / KPT02E8-4S
Circ. Plug Shell#8 4 Pin Contacts / K6F84P / 2 / PEI-Genesis / KPT06F8-4P
Metal Dust Cap Shell Size 8 / AA003189-01 / 1 / PEI-Genesis / MS3181-8C
Circ.Conn Box MountRecept 6 Sockets / AA003190-01 / 1 / PEI-Genesis / KPT02E10-6S
Circ. Plug Shell#10 6 Pin Contacts / K6F106P / 1 / KPT06F10-6P
MS3116F10-6P
Mechanical parts
0-LASER MOUNT PLATE-M.100 / SMC0101G / 2 / Bomem / SMC0101G
"O"-RING #121 BUNA-N / IMZ1121B / 2 / Bomem / 121 BUNA-N
BA - Thermal Plate - BMXS Board - MRXS / AA000598-01 / 1 / Bomem / N/A
0 - Metrology Board Support / SMC1802G / 1 / Bomem / N/A
SMA protective cap with chain / 905-163 / 2 / Bomem / 905-163
Modified Thermal Pad / AA000407-01 / 1 / Bomem
SPACER HEX.ALUMINUM 4-40 X 1/2 / IMZ0594 / 5 / Bomem
POWER AMP HEATSINK AND ADAPTOR (ARIES) / AA003197-01 / 1 / Qualitech / N/A
COMM. CONNECT. HOLDER (ARIES) / AA003198-01 / 1 / Metaux Presses