Milgard Essence ™ Series Fiberglass Windows-9000 Series Fiberglass

3-Part Specification

GENERAL NOTES TO SPECIFIER:

THIS SPECIFICATION SECTION HAS BEEN PREPARED TO ASSIST DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT OR OFFICE MASTER SPECIFICATIONS. IT FOLLOWS GUIDELINES ESTABLISHED BY THE CONSTRUCTION SPECIFICATINS INSTITUTE, AND THEREFORE MAY BE USED WITH MOST MASTER SPECIFICATION SYSTEMS WITH MINOR EDITNG.

EDIT CAREFULLY TO SUIT PROJECT REQUIREMENTS. MODIFY AS NECESSARY AND DELETE ITEMS THAT ARE NOT APPLICATBLE. VERIFYU THAT REFERENCED SECTION NUMBERS AND TITLES ARE CORRECT. (NUMBERS AND TITLES REFERENCED ARE BASED ON MASTERFORMAT, 2004 EDITION).

THIS SECTION ASSUMES THE PROJECT MANUAL WILL CONTAIN COMPLETE DIVEISION 1 DOCUMENTS INCLUDING 01 25 13 PRODUCT SUBSTITUTION PROCEDURES, SECTIONS 01 33 00 – SUBMITTAL PROCEDURES, 01 62 00 – PRODUCT OPTIONS, 01 66 00 – PRODUCT STORAGE AND HANDLING REQUIREMENTS, 01 7400 – CLEANING AND WASTE MANAGEMENT, 01 77 00 - CLOSEOUT PROCEDURES, AND 01 78 00 – CLOSEOUT SUBMITTALS. CLOSE COORDINATION WITH DIVISION 1 SECTIONS IS REQUIRED. IF THE PROJECT MANUAL DOES NOT CONTAIN THESE SECTIONS, ADDITIONAL INFORMATION SHOULD BE INCLUDED UNDER THE APPROPRIATE ARTICLES.

THIS IS AN OPEN PROPRIETARY SPECIFICATION ALLOWING USERS THE OPTION OF APPROVING OTHER MANUFACTURERS THAT COMPLY WITH THE CIRTERIA SPECIFIED HEREIN.

NOTES TO THE SPECIFIER ARE CONTAINED IN BOXES AND SHOULD BE DELETED FROM FINAL COPY.

OPTIONAL ITEMS REQUIRING SELECTION BY THE SPECIFIER ARE ENCLSED WITHIN BRACKETS, E.G. [35] [40] [45]. MAKE APPROPRIATE SELECTIONS AND DELETE OTHERS.

ITEMS REQUIRING ADDITIONAL INFORMATION ARE UNDERLINED BLANK SPACES, E.G. ______.

OPTIONAL PARAGRAPHS REQUIRING SELECTION OF ONE OF THE OPTIONS ARE SPARATED BY “OR” WITHIN A BOX, E.G. OR

BOLD FACE TYPE IDENTIFIES OPTIONAL PARAGRAPHS AND FEATURES THAT MAY BE INCLUDED OR DELETED DEPENDING ON PROJECT REQUIREMENTS. CONVERT THEBOLD FACE TYPE TO REGULAR TYPE WHEN INCLUDING THESE PARAGRAPHS OR FEATURES.

REVISE FOOTER TO SUIT PROJECT/OFFICE REQUIREMENTS.

ELECTRONIC VERISIONS OF THIS SPECIFIFATION UTILIZE AUTOMATIC PARAGRAPH NUMBERING.WHEN EDITING IS COMPLETE, DELETE ALL TEXT ON THIS PAGE, THEN REMOVE THE SECTION BREAK AT THE TOP OF THE NEXT PAGE TO REMOVE THIS PAGE FROM THE DOCUMENT.

Milgard Essence ™ Series Fiberglass Windows-9000 Series Fiberglass

3-Part Specification

SECTION 08 54 13

MASTER FORMAT™ 2004 EDITION

FIBERGLASS WINDOWS

PART 1 – GENERAL

SPECIFIER NOTE: INFORMATION & DATA CONTAINED IN THIS GUIDE IS ACCURATE AS OF SEPTEMBER 2010. DUE TO ONGOING PRODUCT UPDATES, DATA MAY CHANGE OVER TIME. PLEASE CONTACT YOUR LOCAL MILGARD MANUFACTURER REPRESENTATIVE FOR COMPLETE PRODUCT DETAILS. PLEASE VISIT FOR THE LATEST UPDATES.

1.1SUMMARY

  1. Section Includes:
  2. Awning Windows
  3. Casement Windows
  4. Double Hung Tilt Windows
  5. Gliding Windows
  6. Picture Windows
  7. Radius Windows
  8. Glazing
  9. Accessories
  1. Related Sections:

SPECIFIER NOTE: INSERT APPROPRIATE SECTION NUMBERS AND TITLES BELOW FOR WINDOW AND DOOR FLASHING, INSTALLATION SEALANT AND PAINTING OF INTERIOR FRAME, SASH, AND DIVIDED LITE GRIDS IF DESIRED. WINDOWS ARE FURNISHED IN EITHER UNFINISHED PINE, PRIMED WHITE PINE OR UNFINISHED DOUGLAS FIR.

  1. 08 54 13- Fiberglass Windows.
  2. 08 16 13- Fiberglass Doors (Swing).
  3. 08 16 73- Sliding Composite Doors.
  4. ______- ______.
  5. ______- ______. Finishing of interior wood frame and sash surfaces.

SPECIFIER NOTE: INCLUDE APPROPRIATE LANGUAGE BELOW IF PRODUCTS SPECIFIED IN THIS SECTION ARE TO BE BID AS ALTERNATES. OTHERWISE DELETE FOLLOWING PARAGRAPH.

  1. Alternates
  2. Reference Section 01 23 00- Alternates

1.2SUBMITTALS

  1. Reference Section 01 33 00 - Submittal Procedure; submit following items:
  1. Product Data: Submit Milgard’s product data
  2. Shop Drawings: Include window schedule, elevations, sections, details, & multiple- window assembly details. (Please include head, sill & jamb conditions; operable parts & direction/venting; and special mullion reinforcement details.)
  3. Samples: Submit selection samples for verification, include the following:
  4. Exterior Color: Minimum 1x4 color chips on fiberglass substrate: (Specify)
  5. Wood Sample: Minimum 1x4 species sample: (Specify)
  6. Glass, showing specified tint color. (Specify)
  7. Hardware: Sample of style & typical finish: (Specify)
  1. Quality Assurance/Control Submittals:
  2. Qualifications: Proof of manufacturer’s qualifications
  3. U-Factor and structural rating charts required for AAMA and NFRC labeling requirements
  4. Installation Instructions: AAMA 2400, (“Mounting Flange Installation”) or AAMA 2410 (“Flush Fin Installation”)
  1. Closeout Submittals: Reference Section 01 78 00 – Submit following items:
  1. Temporary window labels to identify windows that labels were applied to
  2. Owner’s Manual/Maintenance instructions
  3. Special Warranties

1.3QUALITY ASSURANCE

  1. Overall Standards: Comply with ANSI/AAMA/101/I.S.2, except where noted herein
  1. Manufacturer Qualifications:
  1. Minimum 10 years experience in producing fiberglass windows.
  2. Member AAMA & NFRC.
  1. Regulatory Requirements and Approvals:

SPECIFIER NOTE: INSERT LOCAL REGULATORY REQUIREMENTS

  1. Certifications for Insulated Glass Units:
  1. Insulated glass units are certified to ASTM E2188/E2190 per the Associated Laboratories Incorporated (ALI) guidelines.
  1. AAMA: Windows shall be Silver Label certified with label attached to frame per AAMA requirements
  2. NFRC: Windows shall be NFRC certified with temporary U-factor label applied to glass and an NFRC tab added to permanent AAMA frame label

1.4DELIVERY, STORAGE and HANDLING

  1. General: Reference Section 01 66 00 – Product Storage and Handling Requirements.
  2. Comply with manufacturers/dealers ordering instructions and lead time requirements to avoid construction delays.
  3. Delivery: Deliver materials in manufacturer’s standard packaging for protection of product
  4. Storage & Protection: Store products away from exposure to environmental conditions that may be harmful to materials
  5. Store materials off ground. Provide cover from weather and construction activity
  6. Follow manufacturer’s instructions on label applied to units

1.5WARRANTY

SPECIFIER NOTE: SELECT PERTINENT “RESIDENTIAL” WARRANTY BELOW FOR OWNER OCCUPIED SINGLE FAMILY RESIDENTIAL AND MULTI-FAMILY RESIDENTIAL PROJECTS; SELECT “COMMERCIAL” WARRANTY FOR NON-OWNER OCCUPIED CONDOMINIUMS, MULTI-FAMILY AND COMMERCIAL PROJECTS.

  1. Residential Special Warranty: (Owner Occupied Single Family Residential)
  2. Full Lifetime Warranty including glass breakage to original homeowner
  3. Transferability:
  1. Permit unlimited transfer of ownership in first 10 years
  2. Upon first transfer of ownership, warranty period shall become ten years from date of original purchase
  3. Guarantee windows against defects in materials and workmanship including costs for parts and labor. Wood surfaces are required to be finish coated per manufacturer’s instructions
  4. Submit, for Owner’s acceptance, manufacturer’s Full Lifetime Warranty document

OR

  1. Residential Special Warranty: (Owner Occupied multi-family residential)
  2. Ten Year Multi-Family Limited Warranty

OR

  1. Commercial Warranty:
  2. Ten Year Warranty
  3. Guarantee windows against defects in materials and workmanship including costs for parts and labor. Wood surfaces are required to be finish coated per manufacturer’s instructions

Part -2 PRODUCTS

2.1MANUFACTURER

  1. Products supplied by the following manufacturer:
  1. Milgard Manufacturing

1010 54th Avenue East

Tacoma, WA 98424

2. Phone: (800)-Milgard (645-4273)

3. Website:

4. Manufacturer’s Representative:

SPECIFIER NOTE: INSERT NAME, ADDRESS AND PHONE NUMBERS OF MANUFACTURER’S REPRESENTATIVE BELOW

Name: ______

Telephone: ______

Fax: ______

E-mail: ______

  1. Window Series: Milgard Essence™ Series
  2. Substitutions: Reference Section 01 25 13- Product Substitution Procedures

2.2MANUFACTURED UNITS

  1. Proprietary Products: Multi-Chambered Fiberglass Pultrusion Windows
  2. Essence Series Awning Windows
  3. Essence Series Casement Windows
  4. Essence Series Tilt Double Hung Windows
  5. Essence Series Gliding Windows
  6. Essence Series Picture Windows
  7. Essence Series Radius Windows
  8. Glazing
  9. Accessories
  10. Substitutions: No substitutions permitted

2.3MATERIALS

  1. Frame and Sash
  2. Multi-chambered fiberglass pultrusion exterior
  3. 15 powder coat colors
  4. Wood Interior
  5. Unfinished Pine, Primed Pine or Unfinished Douglas Fir
  1. Weather-Stripping:
  2. Double Hung/Horizontal Slider: Foam filled seal
  3. Casement/Awning: Vinyl compression bulb seal

SPECIFIER NOTE: VERIFY THAT WINDOW FLASHING MATERIAL AND INSTALLATION SEALANT IS SPECIFIED IN APPRORIATE SECTIONS.

2.4SYSTEM DESCRIPTION

  1. General Performance Requirements: Products & systems provided must have been manufactured, fabricated, and installed to the following performance criteria:
  2. Comply with ANSI/AAMA/NWWDA 101/I.S.2, except as noted herein
  3. Performance Class: (Specify)
  4. Performance Grade: (Specify)
  5. U-Factor (NFRC 100): (Specify)
  6. SHGC – Solar Heat Gain Coefficient (NFRC 200): (Specify)
  7. OITC – Outdoor-Indoor Transmission Class (ASTM E90): (Specify)
  8. STC – Sound Transmission Class (ASTM E90): (Specify)
  1. Structural Requirements: Products & systems provided must be capable of withstanding wind loads based on testing units representative of those indicated for Project that pass AAMA/NWWDA 101/I.S.2/NAFS, Uniform Structural Load Test:
  1. Design Wind Loads: Determine design wind loads, according to ASCE, Section 6, applicable to Product from basic wind speeds (MPH) at 33 feet above grade, based upon mean roof heights indicated on Elevations/Drawings
  1. Basic Wind Speed: (Specify)
  2. Importance Factor: (Specify)
  3. Exposure Category: (Specify)
  4. Wind Load Requirement: (Specify)
  5. WINDOW TYPES

SPECIFIER NOTE: SELECT FROM THE FOLLOWING WINDOW TYPES BASED ON PROJECT REQUIREMENTS. PLEASE NOTE RELATED NAIL FIN AND INSERT STYLES OF WINDOWS. DELETE WINDOW TYPES NOT USED.

  1. Awning (New construction)– 9400 Series (Crank-out: short bottom rail); 9420 Series (Crank-out: tall bottom rail); [1-3/8 inch (35 mm) nail fin setback] [1 inch (25 mm) nail fin setback] [Z-Bar flush fin retrofit trim]:
  2. Frame: Minimum 3 ¼” at sill (83 mm) deep; Minimum -2 7/8” (73mm) at jamb and head; multi-chambered fiberglass pultrusion
  3. Sash: Minimum 2 ½” inch (64 mm) deep, multi-chambered fiberglass pultrusion
  4. Structural Class: AP-LC60. (Projected performance for a 4030)
  5. Hardware:
  1. Scissor-arm, stainless-steel, rotary operator, with nested, fold-down, handle
  2. Dual-lever, single-point, locking mechanism (standard, size dependent, TBD)
  3. Dual-lever, multi-point, around-the-corner locking mechanism (optional, size dependent, TBD)
  4. Removable lock-operator handle and escutcheon covers
  5. Two-bar, stainless-steel, friction style, hinge system in multiple sizes (size dependent (AWH), HFA option, automatically selected by ERP system)
  6. Fixed Sash Picture Window (New construction)-9340 Series-short bottom rail; 9350 Series- tall bottom rail):
  7. Structural Class: FW-LC60. (Projected performance for a 4030)
  8. Sightlines: Equal to operating units
  1. Awning (Insert frame) - 94000 Series (Crank-out: short bottom rail); 94200 Series (Crank-out: tall bottom rail)
  2. Frame: Minimum 3 ¼” inch at sill (83 mm) deep, multi-chambered fiberglass pultrusion. At jamb and head- 2 7/8” (73mm)
  3. Sash: Minimum 2 ½” inch (64 mm) deep, multi-chambered fiberglass pultrusion
  4. Structural Class AP-LC60. (Projected performance for a 4030)
  5. Hardware:
  6. Scissor-arm, stainless-steel rotary operator, with nested, fold-down, handle
  7. Dual-lever, single-point, locking mechanism (standard, size dependent, TBD)
  8. Dual-lever, multi-point, around-the-corner locking mechanism (optional, size dependent, TBD)
  9. Removable lock-operator handle and escutcheon covers
  10. Two-bar, stainless-steel, friction style, hinge system in multiple sizes (size dependent (AWH), HFA option, automatically selected by ERP system)
  11. Fixed Sash Picture Window (Insert frame) - 93400 Series-short bottom rail; 93500 Series-tall bottom rail:
  12. Structural Class: FW-LC60. (Projected performance for a 4030)
  13. Sightlines: Equal to operating units
  1. Casement (New construction) - 9500 Series (Crank-out: short bottom rail); 9520 Series (Crank-out: tall bottom rail); [1-3/8 inch (35 mm) nail fin setback] [1 inch (25 mm) nail fin setback] [Z-Bar flush fin retrofit trim]:
  2. Frame: Minimum 3 ¼” inch at sill (83 mm) deep, multi-chambered fiberglass pultrusion. At jamb and head- 2 7/8” (73mm)
  3. Sash: Minimum 2 ½” inch (64 mm) deep, multi-chambered fiberglass pultrusion
  4. Structural Class: C-LC60. (Projected performance for a 3060)
  5. Hardware:
  6. Dual-arm, stainless-steel, rotary operator with nested, fold-down handle. (standard, size dependent, AWW ≥24.0”)
  7. Dyad-style, stainless-steel, rotary operator with nested, fold-down handle. (optional, size dependent, AWW <24.0”)
  8. Multi-point, stainless steel lock bar system with single-point lock bar operator
  9. Removable lock-operator handle and escutcheon covers
  10. Two-bar, stainless-steel, standard duty egress hinge (optional, size dependent; Average window width between 17” and 24”)
  11. Two-bar, stainless-steel, standard duty hinge (standard, weight dependent, sash weight <75 lbs.)
  12. Two-bar, stainless-steel, heavy duty hinge (optional, weight dependent, sash weight ≥ 75 lbs.)
  13. Fixed Sash Picture Window (New construction) - 9340 Series-short bottom rail;9350 Series-tall bottom rail:
  14. Structural Class: FW-LC60. (Projected performance 3060)
  15. Sightlines: Equal to operating units
  16. Casement (Insert frame) - 95000 Series (Crank-out: short bottom rail); 95200 Series (Crank-out: tall bottom rail)
  17. Frame: Minimum 3 ¼” inch at sill (83 mm) deep, multi-chambered fiberglass pultrusion. At jamb and head- 2 7/8” (73mm)
  18. Sash: Minimum 2 ½” inch (64 mm) deep, multi-chambered fiberglass pultrusion
  19. Structural Class: C-LC60. (Projected performance for a 3060)
  20. Hardware:
  21. Dual-arm, stainless-steel, rotary operator with nested, fold-down handle. (standard, size dependent, AWW ≥24.0”)
  22. Dyad-style, stainless-steel, rotary operator with nested, fold-down handle. (optional, size dependent, AWW <24.0”)
  23. Multi-point, stainless steel lock bar system with single-point lock bar operator
  24. Removable lock-operator handle and escutcheon covers
  25. Two-bar, stainless-steel, standard duty egress hinge (optional, size dependent; Average window width between 17” and 24”)
  26. Two-bar, stainless-steel, standard duty hinge (standard, weight dependent, sash weight <75 lbs.)
  27. Two-bar, stainless-steel, heavy duty hinge (optional, weight dependent, sash weight ≥ 75 lbs.)
  28. Fixed Sash Picture Window (Insert frame) - 93400 Series-short bottom rail; 93500 Series-tall bottom rail:
  29. Structural Class: FW-LC60. (Projected performance for a 3060)
  30. Sightlines: Equal to operating units
  1. Double-Hung Tilt (New construction) - 9200 Series, [1 inch (25 mm) nail fin setback] [1-3/8 inch (35 mm) nail fin setback]:
  2. Frame: Minimum [2 3/16” (55.6 mm)] [5 1/16” (128.58 mm)] deep, multi-chambered fiberglass pultrusion
  3. Sash: Minimum [2” (50.8 mm)] [1 ¾” (44.5 mm)] deep, multi-chambered fiberglass pultrusion. Tilt-in upper and lower sash
  4. Structural Class:
  5. DH-LC30 (projected performance for a 4080)
  6. DH-LC50 (projected performance for a 3050)
  7. Hardware:
  8. Concealed block and tackle balance system (< 45 pounds per sash)
  9. Concealed spiral balancer balance system (> 45 pounds per sash)
  10. Lower-sash, lift-handle (optional)
  11. Upper-sash, finger pull (optional)
  12. Flush mounted SmartTouch™ lock (standard)
  13. Top mounted Spoon style, cam lock (optional)
  14. Anti-slam/Anti-mar, push button style, tilt latch system (standard)
  15. Fixed Sash Picture Window (New construction) - 9310 Series:

a. Structural Class:

  1. FW-LC30 (projected performance for a 8080)
  2. FW-LC50 (projected performance for a 3050)
  1. Sightlines: Equal to operating units
  1. Double-Hung Tilt (Insert frame) - 92008 Series (8 degree sill); 92014 (14 degree sill):
  2. Frame: Minimum [2 3/16” (55.6 mm)] [5 1/16” (128.58 mm)] deep, multi-chambered fiberglass pultrusion
  3. Sash: Minimum [2” (50.8 mm)] [1 ¾”(44.5 mm)] deep, multi-chambered fiberglass pultrusion. Tilt-in upper and lower sash
  4. Structural Class:
  5. DH-LC30 (projected performance for a 4080)
  6. DH-LC50 (projected performance for a 3050)
  7. Hardware:
  8. Concealed block and tackle balance system (< 45 pounds per sash)
  9. Concealed spiral balancer balance system (> 45 pounds per sash)
  10. Lower-sash, lift-handle (optional)
  11. Upper-sash, finger pull (optional)
  12. Flush mounted SmartTouch™ lock (standard)
  13. Top mounted Spoon style, cam lock (optional)
  14. Anti-slam/Anti-mar, push button style, tilt latch system (standard)
  15. Fixed Sash Picture Window (Insert frame)- 93108 Series (8 degree sill); 93114 (14 degree sill):
  16. Structural Class:
  17. FW-LC30 (projected performance for a 8080)
  18. FW-LC50 (projected performance for a 3050)
  19. Sightlines: Equal to operating units
  1. Glider (Horizontal Slider) - 9100 Series, [1-3/8 inch (35 mm) nail fin setback] [1 inch (25 mm) nail fin setback] [Z-Bar flush fin retrofit trim]:
  2. Frame: Minimum [2 3/16” (55.6 mm)] [5 1/16” (128.58 mm)] deep, multi-chambered fiberglass pultrusion
  3. Sash: Minimum [2” (50.8 mm)] [1 ¾” (44.5 mm)] deep, multi-chambered fiberglass pultrusion. Tilt-in upper and lower sash
  4. Structural Class:
  5. HS-LC40 (projected performance for a 6060)
  6. HS-LC30 (projected performance for a double vent Glider 12060 XOX)
  7. Hardware:
  8. Adjustable, concave, acetyl rollers with stainless steel axle and needle-bearing hub
  9. Extruded aluminum, color-matched, monorail roller track
  10. Flush mounted SmartTouch™ lock (standard)
  11. Top mounted Spoon style, cam lock (optional)
  12. Operable-sash, finger pull (optional)
  13. Anti-slam/Anti-mar, push button style, tilt latch sash removal/retention system (standard)
  14. Fixed Sash Picture Window (New construction)- 9310 Series :
  15. Structural Class:
  16. FW-LC30 (projected performance for a 8080)
  17. FW-LC50 (projected performance for a 3050)
  18. Sightlines: Equal to operating units
  19. Glider (Horizontal Slider) - (Insert frame) - 91008 Series (8 degree sill); 91014 (14 degree sill)
  20. Frame: Minimum [2 3/16” (55.6 mm)] [5 1/16” (128.58 mm)] deep, multi-chambered fiberglass pultrusion
  21. Sash: Minimum [2” (50.8 mm)] [1 ¾”(44.5 mm)] deep, multi-chambered fiberglass pultrusion. Tilt-in upper and lower sash
  22. 3. Structural Class:
  23. HS-LC40 (projected performance for a 6060).
  24. HS-LC30 (projected performance for a double vent Glider 12060 XOX)
  25. Hardware:
  26. Adjustable, concave, acetyl rollers with stainless steel axle and needle-bearing hub
  27. Extruded aluminum, color-matched, monorail roller track
  28. Flush mounted SmartTouch™ lock (standard)
  29. Top mounted Spoon style, cam lock (optional)
  30. Operable-sash, finger pull (optional)
  31. Anti-slam/Anti-mar, push button style, tilt latch sash removal/retention system (standard)
  32. Fixed Sash Picture Window (Insert frame)- 93108 Series (8 degree sill); 93114 (14 degree sill):
  33. Structural Class:
  34. FW-LC30 (projected performance for a 8080)
  35. FW-LC50 (projected performance for a 3050)
  36. Sightlines: Equal to operating units
  1. Picture Window- Direct Set (non-bent, special-shape picture window):
  2. 9300 Series- New construction frame
  3. Minimum [3 11/16 inch (93.66 mm)] [5 1/16” inch (128.58 mm)] deep, multi-chambered fiberglass pultrusion with integral wood liner
  4. Structural Class: FW-LC50 (projected performance)
  5. 93000 Series- Insert frame
  6. Minimum [3 11/16 inch (93.66 mm)] [5 1/16” inch (128.58 mm)] deep, multi-chambered fiberglass pultrusion with integral wood liner
  7. Structural Class: FW-LC50 (projected performance)
  1. Picture Window Radius- 9700 Series, [1-3/8 inch (35 mm) nail fin setback] ABS profile with integral wood liner:
  2. Standard frame (used for radius of 3 feet )
  3. Minimum [3 11/16 inch (93.66 mm)] [5 1/16” inch (128.58 mm)] deep, ABS profile with integral wood liner
  4. Structural Class: FW-LC50 (projected performance)
  5. Narrow frame: (must be used for radius <3 feet; can be used > 3 feet)
  6. Minimum [2 5/8 inch (66.67 mm)] [5 1/6” inch (128.58 mm)] deep, ABS profile with integral wood liner
  7. Structural Class: FW-LC50 (projected performance)
  1. Bay Windows: (Not currently available. Part of future launch phase)
  2. Unit: Casement or Double Hung: (Specify)
  3. Unit configuration and window types as shown on Drawings; mulled together to form single window unit.
  4. 3. Assembly posts at ##, ##, ## degrees: (Specify)
  5. Bow Windows: (Not currently available. Part of future launch phase)
  6. Unit: Casement or Picture: (Specify)
  7. Unit configuration and window types as shown on Drawings; mulled together to form single window unit.
  8. Assembly posts at 15 degrees.

2.6GLAZING