US BANK CENTER

US BANK CENTER

777 E. Wisconsin Ave,

Milwaukee, Wisconsin, 53202

ESCALATOR / QEI PERFORMANCE INSPECTION

EQUIPMENT INVENTORY

FACILITY NUMBER: UNITS 1 & 2

DIRECTION: UP ------#1

DOWN ------#2

LOCATION: EAST SIDE

WISCONSIN TO MICHIGAN

MICHIGAN TO WISCONSIN

INSTALLATION DATE: 1970

INSTALLATION CODE: NO TAG

TYPE: ESCALAINE

MANUFACTURER: OTIS

JOB #: #1 – 325032

#2 - 325033

STEP WIDTH: 40 INCHES / 48 INCH UNIT

TYPE OF CONTROLS: OTIS

RISE:

CAPACITY: 9000 LBS

CONTRACT SPEED: 90 FPM / .5 MLS

CITY/ STATE

NUMBER: 2 DN-433

MILWAUKEE 1 UP -432

UPPER END PIT
ESCALATOR 02/DN 01/UP
CODE INSTALLATION PLATE: NONE NONE

MACHINE: OK- 60ES OK- 60 ES

MOTOR SIZE: 10 HP 10 HP

1200 RPM 1200 RPM

23 AMPS 23 AMPS

MOTOR VENT: OK OK

BRAKE: OK OK

EMERGENCY BRAKE: OK OK

FLEXIBLE SHAPE CPLG: N/A N/A

MAIN DRIVE GEAR: OK OK

SLACK CHAIN DEVICE: OK OK

MAIN DRIVE GEAR BOX: OK OK

GEAR OIL RESERVOIR: OK OK

TRACK: OK OK

TRANSFER BAR: OK OK

STEP GUARD: OK OK

CONTROLLER: OK OK

10 NE

BROKEN STEP SWITCH: NO NO

PIT LIGHT: POOR W/ OK

PLUG

GUARD: N/A N/A

GFI: NO NO

CHAIN OILERS: NO NO

HOUSEKEEPING: OK OK

ACCESS COVER SWITCHES: NONE NONE

UPPER HANDRAIL INLET SW: NO NO

HANDRAIL STOPPING MONITOR: NO NO

LEVEL STEP SW: NO NO

UPPER COMB INLET SW: NO NO

MISSING STEP SWITCH: NO NO

UPPER STOP SWITCH: OK OK

NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2

OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW

US BANK CENTER

CENTER TRUSS – INTERIOR
ESCALATOR 02/DN 01/UP

STEP CHAIN SPROCKETS

LH: OK OK

RH: OK OK

MAIN HANDRAIL DRV SPROCKETS / NEWELL DRIVES

LH: OK OK

RH: OK OK

HANDRAIL SPROCKETS
LH: OK OK

RH: OK OK

HANDRAIL CHAIN
LH: OK OK

RH: OK OK

HANDRAIL TENSIONING
MECHANISM: OK OK

STEP CHAIN STRETCH (OVER TEN STEPS)
LH: OK OK

RH: OK OK

HANDRAIL CHAINS: OK OK

STEP CHAINS: OK OK

DRIVE CHAINS: OK OK

EXTERNAL GEAR LARGE: N/A N/A

EXTERNAL GEAR SMALL: N/A N/A

ESCALATOR 02/DN 01/UP

DEMARCATION LIGHTS
TOP: OK OK

BOTTOM: OK OK

STEP UPTHRUST SWITCH: OK OK

SKIRT SWITCHES
TOP: OK OK

BOTTOM: OK OK

HOUSEKEEPING: OK OK


BOTTOM END PIT

ESCALATOR 02/DN 01/UP

STEP CHAIN SPROCKETS
LH: OK OK

RH: OK OK

STEP CHAIN SWITCHES
LH: OK OK

RH: OK OK

LOWER COMB IMPACT SW: NO NO

STEP GUARD: OK OK

PIT STOP SWITCH: OK OK

LOWER HANDRAIL INLET SW: NO NO

PIT LIGHT: PORCELAIN PORCELAIN

GFI: NO NO

HOUSEKEEPING: OK OK

SEISMIC SWITCH

EXISTING: NO NO


EXTERIOR EQUIPMENT

ESCALATOR 02/DN 01/UP

STEP TREADS & RISERS: OK OK

DEMARCATION STRIPS: NO NO

SKIRT BRUSHES: YES YES

STEP ROLLERS: OK OK

STEP STOPPING INCHES: 1” 1”

QUALITY OF RIDE: OK OK

COMBPLATES
TOP: OK OK

BOTTOM: OK OK

FLOOR PLATES
TOP: OK OK

BOTTOM: OK OK

HANDRAILS
LH: NI NI

RH: NI NI

HANDRAIL SKIRT GUARD
LH: OK OK

RH: OK OK

HANDRAIL GUARD SWITCHES
TOP: NO NO

BOTTOM: NO NO

STOP SWITCHES / NEWELL ENDS
TOP: OK OK

BOTTOM: OK OK

START SWITCHES
TOP: OK OK

BOTTOM: OK OK

EXTERNAL GEAR LARGE: N/A N/A

EXTERNAL GEAR SMALL: N/A N/AESCALATOR 02/DN 01/UP

BALLUSTRADES /GLASS

DECK

LH: OK OK

RH: OK OK

PANELS

LH: OK OK

RH: OK OK

SKIRTS

LH: OK OK

RH: OK OK

SKIRT TO STEP CLEARANCE ( LESS THAN 5/32 )
TOP
LH: OK OK

RH: OK OK

CENTER
LH: OK OK

RH: OK OK

BOTTOM
LH: OK OK

RH: OK OK

SKIRT COMBPLATE LIGHT: NO NO

SKIRT LIGHTS

TOP R: N/A N/A

TOP L: N/A N/A

BOTTOM R: N/A N/A

BOTTOM L: N/A N/A

DECK ANTI-SLIDE KNOBS: NO NO

SOFFIT APEX GUARDS: N/A N/A

LIGHTING 10FT CANDLE MIN: OK OK

OUTER DECK GUARDS: N/A N/A

SAFETY SIGNS: NI NI

NON COMPLIANT

NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2

OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW

US BANK CENTER

US BANK CENTER

MILWAUKEE, WISCONSIN

ESCALATORS 1 & 2

CORRECTIVE ITEMS

The following minimum items need corrective action taken. Documentation on completion is required.

City Number 1 - 432 Category 1 testing 7 – 2-23-15 DUE

2 – 433 8 - 2-23-15 DUE

ESCALATOR 2 (DN)

See Executive Summary

ESCALATOR 1 (UP)

See Executive Summary.


US BANK CENTER

MILWAUKEE, WISCONSIN

ESCALATORS 1 & 2

RECOMMENDED IMPROVEMENTS

See Executive Summary.

NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2

OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW