US BANK CENTER
US BANK CENTER
777 E. Wisconsin Ave,
Milwaukee, Wisconsin, 53202
ESCALATOR / QEI PERFORMANCE INSPECTION
EQUIPMENT INVENTORY
FACILITY NUMBER: UNITS 1 & 2
DIRECTION: UP ------#1
DOWN ------#2
LOCATION: EAST SIDE
WISCONSIN TO MICHIGAN
MICHIGAN TO WISCONSIN
INSTALLATION DATE: 1970
INSTALLATION CODE: NO TAG
TYPE: ESCALAINE
MANUFACTURER: OTIS
JOB #: #1 – 325032
#2 - 325033
STEP WIDTH: 40 INCHES / 48 INCH UNIT
TYPE OF CONTROLS: OTIS
RISE:
CAPACITY: 9000 LBS
CONTRACT SPEED: 90 FPM / .5 MLS
CITY/ STATE
NUMBER: 2 DN-433
MILWAUKEE 1 UP -432
UPPER END PIT
ESCALATOR 02/DN 01/UP
CODE INSTALLATION PLATE: NONE NONE
MACHINE: OK- 60ES OK- 60 ES
MOTOR SIZE: 10 HP 10 HP
1200 RPM 1200 RPM
23 AMPS 23 AMPS
MOTOR VENT: OK OK
BRAKE: OK OK
EMERGENCY BRAKE: OK OK
FLEXIBLE SHAPE CPLG: N/A N/A
MAIN DRIVE GEAR: OK OK
SLACK CHAIN DEVICE: OK OK
MAIN DRIVE GEAR BOX: OK OK
GEAR OIL RESERVOIR: OK OK
TRACK: OK OK
TRANSFER BAR: OK OK
STEP GUARD: OK OK
CONTROLLER: OK OK
10 NE
BROKEN STEP SWITCH: NO NO
PIT LIGHT: POOR W/ OK
PLUG
GUARD: N/A N/A
GFI: NO NO
CHAIN OILERS: NO NO
HOUSEKEEPING: OK OK
ACCESS COVER SWITCHES: NONE NONE
UPPER HANDRAIL INLET SW: NO NO
HANDRAIL STOPPING MONITOR: NO NO
LEVEL STEP SW: NO NO
UPPER COMB INLET SW: NO NO
MISSING STEP SWITCH: NO NO
UPPER STOP SWITCH: OK OK
NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2
OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW
US BANK CENTER
CENTER TRUSS – INTERIOR
ESCALATOR 02/DN 01/UP
STEP CHAIN SPROCKETS
LH: OK OK
RH: OK OK
MAIN HANDRAIL DRV SPROCKETS / NEWELL DRIVES
LH: OK OK
RH: OK OK
HANDRAIL SPROCKETS
LH: OK OK
RH: OK OK
HANDRAIL CHAIN
LH: OK OK
RH: OK OK
HANDRAIL TENSIONING
MECHANISM: OK OK
STEP CHAIN STRETCH (OVER TEN STEPS)
LH: OK OK
RH: OK OK
HANDRAIL CHAINS: OK OK
STEP CHAINS: OK OK
DRIVE CHAINS: OK OK
EXTERNAL GEAR LARGE: N/A N/A
EXTERNAL GEAR SMALL: N/A N/A
ESCALATOR 02/DN 01/UP
DEMARCATION LIGHTS
TOP: OK OK
BOTTOM: OK OK
STEP UPTHRUST SWITCH: OK OK
SKIRT SWITCHES
TOP: OK OK
BOTTOM: OK OK
HOUSEKEEPING: OK OK
BOTTOM END PIT
ESCALATOR 02/DN 01/UP
STEP CHAIN SPROCKETS
LH: OK OK
RH: OK OK
STEP CHAIN SWITCHES
LH: OK OK
RH: OK OK
LOWER COMB IMPACT SW: NO NO
STEP GUARD: OK OK
PIT STOP SWITCH: OK OK
LOWER HANDRAIL INLET SW: NO NO
PIT LIGHT: PORCELAIN PORCELAIN
GFI: NO NO
HOUSEKEEPING: OK OK
SEISMIC SWITCH
EXISTING: NO NO
EXTERIOR EQUIPMENT
ESCALATOR 02/DN 01/UP
STEP TREADS & RISERS: OK OK
DEMARCATION STRIPS: NO NO
SKIRT BRUSHES: YES YES
STEP ROLLERS: OK OK
STEP STOPPING INCHES: 1” 1”
QUALITY OF RIDE: OK OK
COMBPLATES
TOP: OK OK
BOTTOM: OK OK
FLOOR PLATES
TOP: OK OK
BOTTOM: OK OK
HANDRAILS
LH: NI NI
RH: NI NI
HANDRAIL SKIRT GUARD
LH: OK OK
RH: OK OK
HANDRAIL GUARD SWITCHES
TOP: NO NO
BOTTOM: NO NO
STOP SWITCHES / NEWELL ENDS
TOP: OK OK
BOTTOM: OK OK
START SWITCHES
TOP: OK OK
BOTTOM: OK OK
EXTERNAL GEAR LARGE: N/A N/A
EXTERNAL GEAR SMALL: N/A N/AESCALATOR 02/DN 01/UP
BALLUSTRADES /GLASS
DECK
LH: OK OK
RH: OK OK
PANELS
LH: OK OK
RH: OK OK
SKIRTS
LH: OK OK
RH: OK OK
SKIRT TO STEP CLEARANCE ( LESS THAN 5/32 )
TOP
LH: OK OK
RH: OK OK
CENTER
LH: OK OK
RH: OK OK
BOTTOM
LH: OK OK
RH: OK OK
SKIRT COMBPLATE LIGHT: NO NO
SKIRT LIGHTS
TOP R: N/A N/A
TOP L: N/A N/A
BOTTOM R: N/A N/A
BOTTOM L: N/A N/A
DECK ANTI-SLIDE KNOBS: NO NO
SOFFIT APEX GUARDS: N/A N/A
LIGHTING 10FT CANDLE MIN: OK OK
OUTER DECK GUARDS: N/A N/A
SAFETY SIGNS: NI NI
NON COMPLIANT
NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2
OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW
US BANK CENTER
US BANK CENTER
MILWAUKEE, WISCONSIN
ESCALATORS 1 & 2
CORRECTIVE ITEMS
The following minimum items need corrective action taken. Documentation on completion is required.
City Number 1 - 432 Category 1 testing 7 – 2-23-15 DUE
2 – 433 8 - 2-23-15 DUE
ESCALATOR 2 (DN)
See Executive Summary
ESCALATOR 1 (UP)
See Executive Summary.
US BANK CENTER
MILWAUKEE, WISCONSIN
ESCALATORS 1 & 2
RECOMMENDED IMPROVEMENTS
See Executive Summary.
NI- NEEDS IMPROVEMENT 9 OF 9 ESCALATORS 1 & 2
OK- ACCEPTABLE May 2016 QEI PERFORMANCE REVIEW