L20/ REVOLVING DOORS

Manufacturers DORMA UK LTD.

WILBURY WAY, HITCHIN, SG4 0AB.

Tel: +44 (0)1462 477 600,

Email:

Web: www.dorma.com

Dimensions: Internal Diameter ______(2000mm – 3600mm*)

Number of wings ______(3 or 4 wing)

Clear Opening height ______(2000mm – 4000mm*)

(*Refer to technical brochure for diameter to height dependency table)

Operating System DORMA KTV-S Glazed Low Energy Servomatic Revolving Door with solid canopy

·  Central axis power assisted revolving door

·  Canopy mounted drive unit

·  Anti vandalism brake (Option)

·  Ceiling integrated down lights

Activation and safety

·  Comprehensive presence sensing safety system comprising passive and active safety devices (Option)

Drum Walls

·  Curved Framed Safety Glass (Option)

·  Metal Panelling (Option)

·  Central Midrails (Option)

Door Wings

·  Framed safety glass with central column (Option)

·  Fine framed safety glass without central column (Option)

·  Central Midrails (Option with central column)

Solid Canopy

·  Minimum 200mm canopy height finished in selected profile coating

·  Prepared for rain proofing

·  Manual external night shield (Option)

·  Manual internal night shield (Option)

Stainless Steel Floor Ring

·  Free issued by DORMA and installed by others

·  Floor matting by others

Aluminium Profile Finish

·  Satin Anodised (Option)

·  Standard RAL (Option)

·  Stainless Steel (Option)

·  Bronze Anodised (Special finish on request)

Break Out Facility Required (Option)

Not required (Option)

Locking Facility Euro profile mechanical locking in the door wings (Option)

Applicable Standards The installation shall comply with BS EN 16005

Electrical Requirements The electrical contractor shall provide a 240-volt AC mains spur to the right-hand side of the opening above and on the same face that each drive unit is fitted. The spur must be switched and fused with a central flex outlet faceplate. A 10 amp residual circuit breaker at the mains board and a 5-amp fuse at the spur shall protect the circuit.