No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / XOSERVE
Owner: / XOSERVE
Version: / 1.0
Status: / For Approval
Date: / 04/03/2016

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
1.0 / 1154 / 04-March-2016 / Project Nexus Implementation Date / For Approval
Contains12different Record Types
Level / Record Name / Occurrence / Optionality
1 / A00_STANDARD_HEADER / 1 / M
1 / RT_U95_INTCONNEC_TRANSFER_OF_OWNERSHIP / 1 / O
2 / RT_S66_CONTACT_DETAILS / Up to 5 / M
3 / RT_S67_ELECTRONIC_DEVICE / Up to 4 / M
2 / RT_S70_ADDRESS / 1 / M
2 / RT_S75_METER_POINT_DETAILS / Up to 500 / M
2 / RT_U71_NTS_OPTIONAL_RATE_DET / 1 / M
2 / RT_U74_CSO_DETAILS / 1 / O
2 / RT_U75_METER_ASSET_DETAILS / Up to 500 / O
1 / RT_U92_INTERCONNECTOR_CNF_RESPONSE / 1 / O
2 / RT_S72_REJECTION_DETAIL / Up to 15 / M
1 / Z99_STANDARD_TRAILER / 1 / M

Note 1

OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places

Note 2

All text fields will be enclosed in double quotes ("")

HD_A00_STANDARD_HEADER

RECORD/FIELD_NAME *Occurs Max 1* / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / DEFINITION: A code identifying the type of request that this record represents.
VALUE:A00
ORGANISATION_ID / M / N / 10 / 0 / DEFINITION: A reference which uniquely identifies a User/Organisation.
FILE_TYPE / M / T / 3 / 0 / DEFINITION: An application specific code used to identify the structure and the usage of the file.
VALUE: TNI
CREATION_DATE / M / D / 8 / 0 / DEFINITION: The date on which the file was generated.
FORMAT: YYYYMMDD
CREATION_TIME / M / M / 6 / 0 / DEFINITION: The time at which the file was generated (within the Creation Date).
FORMAT: HHMMSS
GENERATION_NUMBER / M / N / 6 / 0 / DEFINITION: A sequence number which represents an issue of a file that is unique for a combination of System User and file type. Files of the same file type submitted by a System User or to a System User must have consecutive numbers
Total / 36

RT_U95_INTCONNEC_TRANSFER_OF_OWNERSHIP

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE : U95
SUPPLY_POINT_CONFIRMATION_REFERENCE / M / T / 10 / 0 / A sequential number that uniquely identifies the Confirmation.
NOMINATION_SHIPPER_REF / O / T / 30 / 0 / A reference supplied by the System User when making a Nomination. It may be used by the System User to identify the Nomination and any subsequent Confirmation made for that Nomination.
CONFIRMATION_EFFECTIVE_DATE / M / D / 8 / 0 / The date on which ownership of the Supply Meter Point is requested to commence.
FORMAT: YYYYMMDD.
EXIT_ZONE_IDENTIFIER / M / T / 3 / 0 / A unique reference for the Exit Zone.CONTEXT: For iGT Supply Meter Points the Exit Zone will be based on the CSEP connection and not on the Supply Meter Point Post Code.
LDZ_IDENTIFIER / M / T / 4 / 0 / This field identifies the LDZ to which the Supply Meter Point is associated.
NTS_EXIT_COMMODITY_CHARGE_RATE / M / N / 10 / 4 / The charge per unit of gas exiting the National Transmission System (NTS). CONTEXT: The combined NTS Exit Commodity NO / SO rate or the sum of the separate TO and SO NTS Exit Commodity rate
IINTERCONNECTOR_AGENT_SERV_SETUP_CHARGE_PER_SHIPPER / O / N / 10 / 40 / Allocation Arrangements at Interconnectors -Agent service -Set up charge per shipper
INTERCONNECTOR_TRANSPORTER_SERV_SETUP_CHARGE_PER_SHIPPER / O / N / 10 / 4 / Allocation Arrangements at Interconnectors -Transporter service -Set up charge per shipper
IINTERCONNECTOR_AGENT_SERV_DAILY_CHARGE_PER_SHIPPER / O / N / 10 / 4 / Allocation Arrangements at Interconnectors -Agent service -Daily charge per shipper
INTERCONNECTOR_TRANSPORTER_SERV_DAILY_CHARGE_PER_SHIPPER / O / N / 10 / 4 / Allocation Arrangements at Interconnectors -Transporter service -Daily charge per shipper
ADMIN_MOFFAT_AGENT_SERV_DAILY_CHARGE_PER_SHIPPER / O / N / 10 / 4 / Administration Charges at Moffat -Agent service -Daily charge per shipper
ADMIN_MOFFAT_TRANSPORTER_SERV_DAILY_CHARGE_PER_SHIPPER / O / N / 10 / 4 / Administration Charges at Moffat -Transporter service -Daily charge per shipper
END_USER_CATEGORY / O / N / 10 / 0 / A unique reference for the End User Category.
SUPPLY_POINT_CATEGORY / M / T / 5 / 0 / The category of grouping for which gas is nominated for the Supply Meter Point. VALUES:
VLDMC-Very Large Daily Metered Consumer.
DMC-Daily Metered Consumer
NDMA-Non Daily Metered Aggregate
DMAF-Daily Metered Aggregate Firm.
SUPPLY_METER_POINT_
CLASS / M / N / 1 / 0 / It defines the class type for the supply meter point. VALUES: 1 - Class 1, 2 - Class 2, 3 - Class 3, 4 - Class 4
MARKET_SECTOR_CODE / M / T / 1 / 0 / DEFINITION: A code that specifies that the site is used for domestic or industrial and commercial purposes. Allowable ValuesVALUES: D - Domestic or I – Industrial & Commercial.
SP_MANNED_24_HOURS_ INDICATOR / M / T / 1 / 0 / Detailswhethertheproposedsupplypointismanned24hours for the purposes of emergency contacts. If the supply point will be manned 24 hours then less actual contact details are required.VALUES: Y / N.
RECORDED_DATE / M / D / 8 / 0 / The date on which the original request was recorded on Transporter Systems. FORMAT: YYYYMMDD.
RECORDED_TIME / M / M / 6 / 0 / The time at which the original request was recorded on Transporter Systems. FORMAT: HHMMSS.
SUPPLY_METER_POINT_CLASS / O / N / 1 / 0 / It defines the class type for the Supply Meter Point. VALUES: 1 – Class 1, 2 – Class 2, 3 – Class 3, 4 - Class 4
SEASONAL_LSP_INDICATOR / O / T / 1 / 0 / Indicates whether the Supply Meter Point is a Seasonal LSP.
VALUES: Y or Blank
SEASONAL_LSP_PERIOD_START_MONTH / O / N / 2 / 0 / The last month in a year that offtake is permissible at the Seasonal LSP. VALUES: 4 (April) to 9 (September)
SEASONAL_LSP_PERIOD_END_MONTH / O / N / 2 / 0 / The last month in a year that offtake is permissible at the Seasonal LSP. VALUES: 4 (April) to 9 (September)
GAS_NOMINATION_ID / O / T / 10 / 0 / Gemini system identifier that should be used to nominate gas for the supply meter point.
Total / 170634

RT_S66_CONTACT_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record presents.
VALUE: S66
CONTACT_TYPE / M / T / 3 / 0 / A code which describes the type of contact.
VALUES : EMR - Emergency, ISO -Isolation
(Organisation), ISC – Isolation
(Person or Role), CON – Consumer
CONTACT_TITLE / O / T / 6 / 0 / Title of contact e.g. Mr, Miss, Sir, Doctor, etc.
M – Mandatory where
CONTACT_TYPE = EMR and JOB_TITLE not given
CONTACT_SURNAME / O / T / 30 / 0 / The surname of the contact.
M – Mandatory where
CONTACT_TYPE = CON and site is domestic.
M – Mandatory where
CONTACT_TYPE = EMR and JOB_TITLE not given
CONTACT_INITIALS / O / T / 4 / 0 / Initials of the contact.
M – Mandatory where
CONTACT_TYPE = CON and site
is domestic.
O – Optional where
CONTACT_TYPE = EMR
CONTACT_FIRST_NAME / O / T / 15 / 0 / First Name of the contact.
CONTACT_JOB_TITLE / O / T / 30 / 0 / Contacts Job Title.
M – Mandatory if BOTH
CONTACT_SURNAME and
CONTACT_TITLE not provided
where CONTACT_TYPE = EMR.
CONTACT_EFFECTIVE_DATE / M / D / 8 / 0 / Effective date from when the contact is valid
Total / 99

RT_S67_ELECTRONIC_DEVICE

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE: S67
CONT_ELECTRONIC_COMM_TYPE / M / T / 3 / 0 / A code which classifies the electronic address type.
VALUES: FAX - Fax, PAG – Pager
Number TEL - Telephone, “PAG” or “FAX”
can only be provided if in conjunction with “TEL” (i.e. if
“TEL” is also provided), etc
CONTACT_ELECTRONIC_ADDRESS / M / T / 241 / 0 / Electronic address such as telephone number etc
Total / 247

RT_S70_ADDRESS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S70
BUILDING_NUMBER / O / N / 4 / 0 / Building Number as defined in PAF.
SUB_BUILDING_NAME / O / T / 30 / 0 / Sub Building Name as defined in PAF.
BUILDING_NAME / O / T / 50 / 0 / Building Name as defined in PAF.
PRINCIPAL_STREET / O / T / 40 / 0 / A combination THOROUGHFARE NAME and THOROUGHFARE DESCRIPTOR as defined in PAF.
DEPENDENT_LOCALITY / O / T / 40 / 0 / A named, geographically defined area within a POST TOWN area (a Postal District).CONTEXT: Dependant Locality as defined in PAF.
POST_TOWN / O / T / 40 / 0 / The post town is the location where the street lies.
POSTCODE_OUTCODE / M / T / 4 / 0 / Standard PAF outcode as defined in the PAF digest.
POSTCODE_INCODE / M / T / 4 / 0 / Standard PAF incode as defined in the PAF digest.
Total / 215

RT _S75_METER_POINT_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S75
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
METER_LOCATION_CODE / M / N / 2 / 0 / DEFINITION: A code representing the location of a meter.
VALUES: 0 -Unknown,
1 -Cellar,
2 -Under Stairs,
3 -Hall,
4 -Kitchen,
5 -Bathroom,
6 -Garage,
7 -Canteen
8 -Cloakroom,
9 -Cupboard,
10 -Domestic Science
11 -Front Door,
12 -Hall Cupboard
13 -Kitchen Cupboard
14 -Kitchen Under Sink
18 -Outside WC,
19 -Pantry,
20 -Porch,
21 -Public Bar,
22 -Rear of shop,
23 -Saloon Bar,
24 -Shed,
25 -Shop Front,
26 -Shop Window,
27 -Staff Room,
28 -Store Room,
29 -Toilet,
30 -Under Counter
31 -Waiting Room
32 -Meter Box (Outside),
98 -Other,
99 -Outside.
METER_SERIAL_NUMBER / O / T / 14 / 0 / The manufacturer's meter serial number as held on the physical meter.
SUPPLY_METER_POINT_AQ / M / N / 15 / 0 / The annual offtake quantity of a Supply Meter Point. This AQ may be revised following read submission.
DRE_SERIAL_NUMBER / O / T / 14 / 0 / DEFINITION: The manufacturer’s serial number.
DRE_UNIQUE _NUMBER / O / T / 18 / 0 / A system generated number allocated to each individual daily read equipment record within a location to provide unique identification.
METER_LINK_CODE / O / T / 1 / 0 / DEFINITION: A code defining the functional relationship between meters (the way in which they are linked together) at a given location on the End User’s site. CONTEXT: Populated only when output in conjunction with a RT_S64_OFFER recorded.
VALUES:
P -Primary Meter,
S -Sub-meter,
F -Free Standing Meter,
.
CORRECTION_FACTOR / O / N / 9 / 6 / This is a fixed factor based on pressure/altitude/temperature
OPERATIONAL_STATUS / O / D / 8 / 0 / DEFINITION: Indicates the current operational status of the Meter Point, be it Live, Isolated or Pending Isolation. CONTEXT: Status can be derived by evaluating the value of the field. Live -Not Populated, Isolated -Populated with date in future.
FORMAT: YYYYMMDD
METER_MECHANISM / O / T / 3 / 0 / DEFINITION: The coded value of the description of the Meter Mechanism.
ALLOWABLE VALUES:
CR -Credit,
MT -Mechanical Token,
ET -Electronic Token,
CM -Coin,
PP -Prepayment,
TH -Thrift,
U -Unknown,
NS - SMETS non-compliant
S1 - SMETS Version 1
S2 - SMETS Version 2.
NUMBER_OF_DIALS_OR_DIGITS / M / N / 2 / 0 / DEFINITIONS: Number of dials or digits on the meter which are considered during meter reading. Used to validate meter readings and to determine the number of
complete units consumed. Note: Since there may be cases where the Meter Model is not found (this can be legitimate), there is no error if the meter model for the Meter Point is not found. In this case, the METER_MECHANISM will be set to spaces and the
NUMBER_OF_DIALS_OR DIGITS will be set to 0.
PREVIOUS_SUPPLIER_SHORT_CODE / O / T / 3 / 0 / DEFINITION: A unique short code which gives the identity of the previous supplier for the meter point. CONTEXT: Populated only when output in conjunction with an
RT_S15_TRANSFER_OF_OWNERSHIP.
FORMULA_YEAR_SMP_AQ / O / N / 15 / 0 / The Supply Meter Point AQ that is fixed throughout the formula year for determination of Transportation rates. For Class 3 and Class 4 Supply Meter Points.
AMR_INDICATOR / M / T / 1 / 0 / Indicator to identify whether the site has AMR attached. VALUE: “Y/N”
Total / 118

RT_S75_SMPETER_POINT_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S75
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
METER_LOCATION_CODE / M / N / 2 / 0 / DEFINITION: A code representing the location of a meter.
VALUES: 00 -Unknown,
1 -Cellar,
2 -Under Stairs,
3 -Hall,
4 -Kitchen,
5 -Bathroom,
6 -Garage,
7 -Canteen
8 -Cloakroom,
9 -Cupboard,
10 -Domestic Science
11 -Front Door,
12 -Hall Cupboard
13 -Kitchen Cupboard
14 -Kitchen Under Sink
18 -Outside WC,
19 -Pantry,
20 -Porch,
21 -Public Bar,
22 -Rear of shop,
23 -Saloon Bar,
24 -Shed,
25 -Shop Front,
26 -Shop Window,
27 -Staff Room,
28 -Store Room,
29 -Toilet,
30 -Under Counter
31 -Waiting Room
32 -Meter Box (Outside),
98 -Other,
99 -Outside.
METER_SERIAL_NUMBER / M / T / 14 / 0 / The manufacturer's meter serial number as held on the physical meter.
SUPPLY_METER_POINT_AQ / M / N / 15 / The annual offtake quantity of a Supply Meter Point. This AQ may be revised following read submission.
DRE_SERIAL_NUMBER / O / T / 14 / 0 / DEFINITION: The mmanufacturer’s serial number.
DRE_UNIQUE _NUMBER / O / T / 18 / 0 / A system generated number allocated to each individual daily read equipment record within a location to provide unique identification.
METER_LINK_CODE / O / T / 1 / 0 / DEFINITION: A code defining the functional relationship between meters (the way in which they are linked together) at a given location on the End User’s site. CONTEXT: Populated only when output in conjunction with a RT_S64_OFFER recorded.
VALUES:
P -Primary Meter,
S -Sub-meter,
F -Free Standing Meter,
.
CORRECTION_FACTOR / O / N / 9 / 6 / This is a fixed factor based on pressure/altitude/temperature
OPERATIONAL_STATUS / O / D / 8 / 0 / DEFINITION: Indicates the current operational status of the Meter Point, be it Live, Isolated or Pending Isolation. CONTEXT: Status can be derived by evaluating the value of the field. Live -Not Populated, Isolated -Populated with date in future.
FORMAT: YYYYMMDD
METER_MECHANISM / O / T / 3 / 0 / DEFINITION: The coded value of the description of the Meter Mechanism.
ALLOWABLE VALUES:
CR -Credit,
MT -Mechanical Token,
ET -Electronic Token,
CM -Coin,
PP -Prepayment,
TH -Thrift,
U -Unknown,
NS - SMETS non-compliant
S1 - SMETS Version 1
S2 - SMETS Version 2.
NUMBER_OF_DIALS_OR_DIGITS / M / N / 2 / 0 / DEFINITIONS: Number of dials or digits on the meter which are considered during meter reading. Used to validate meter readings and to determine the number of
complete units consumed. Note: Since there may be cases where the Meter Model is not found (this can be legitimate), there is no error if the meter model for the Meter Point is not found. In this case, the METER_MECHANISM will be set to spaces and the
NUMBER_OF_DIALS_OR DIGITS will be set to 0.
PREVIOUS_SUPPLIER_SHORT_CODE / O / T / 3 / 0 / DEFINITION: A unique short code which gives the identity of the previous supplier for the meter point. CONTEXT: Populated only when output in conjunction with an
RT_S15_TRANSFER_OF_OWNERSHIP.
FORMULA_YEAR_ SMP_ AQ / O / N / 15 / 0 / The Supply Meter Point AQ that is fixed throughout the formula year for determination of Transportation rates. For Class 3 and Class 4 Supply Meter Points.
AMR_INDICATOR / M / T / 1 / 0 / Indicator to identify whether the site has AMR attached. VALUE: “Y/N”
Total / 118

RT_U71_NTS_OPTIONAL_RATE_DET

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. Value:U71
NTS_OPTIONAL_RATE_APPLICABLE / M / T / 1 / 0 / Request for NTS Optional Rate charge.
Allowable Values: Y/N
POSTCODE_OUTCODE / M / T / 4 / 0 / Standard PAF outcode as defined in the PAF digest.
POSTCODE_INCODE / M / T / 4 / 0 / Standard PAF incode as defined in the PAF digest.
SPECIFIED_EXIT_POINT / M / T / 10 / 0 / The Eligible Exit Point (SMP) requesting NTS Optional Rate to be applied to/removed from
SPECIFIED_ENTRY_POINT / O / T / 10 / 0 / Input Terminal Number requesting NTS Optional rate to be applied from. CONTEXT: Mandatory if NTS Optional Rate is requested. This would be acquired from the Transporter.
SPECIFIED_ENTRY_POINT_NAME / O / T / 40 / 0 / Input Terminal Name requesting NTS Optional rate to be applied from. CONTEXT: Mandatory if NTS Optional Rate is requested.
GRID_REFERENCE_ENTRY_POINT / O / T / 9 / 0 / Grid reference for calculation of distance. Where a different Grid Reference Entry Point is to be considered by the Transporter from the original Grid Reference Entry Point provided.
GRID_REFERENCE_EXIT_POINT / O / T / 9 / 0 / Grid reference for calculation of distance. Where a different Grid Reference Exit Point is to be considered by the Transporter from the original Grid Reference Exit Point provided
DISTANCE / O / N / 4 / 1 / Distance calculated from SMP to NTS Entry Point.
SITE_COMPONENT_SOQ / M / N / 10 / 0 / The value used to calculate the rates where an SOQ value is required in the rate calculation. For an NTS site the MNEPOR value is populated. For a CSEP the CSEP_CONNECTION_MAX_SOQ value is populated. For an LDZ Direct Connect site the Nominated SOQ value is populated.
NTS_OPTIONAL_RATE / M / N / 10 / 4 / Rate to be applied
Total / 114
RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. Value:U71
NTS_OPTIONAL_RATE_APPLICABLE / M / T / 1 / 0 / Request for NTS Optional Rate charge.
Allowable Values: Y/N
POSTCODE_OUTCODE / M / T / 4 / 0 / Standard PAF outcode as defined in the PAF digest.
POSTCODE_INCODE / M / T / 4 / 0 / Standard PAF incode as defined in the PAF digest.
SPECIFIED_EXIT_POINT / M / T / 10 / 0 / The Eligible Exit Point (SMP) requesting NTS Optional Rate to be applied to/removed from
SPECIFIED_ENTRY_POINT / O / T / 10 / 0 / Input Terminal Number requesting NTS Optional rate to be applied from. CONTEXT: Mandatory if NTS Optional Rate is requested. This would be acquired from the Transporter.
SPECIFIED_ENTRY_POINT_NAME / O / T / 40 / 0 / Input Terminal Name requesting NTS Optional rate to be applied from. CONTEXT: Mandatory if NTS Optional Rate is requested.
GRID_REFERENCE_ENTRY_POINT / O / T / 9 / 0 / Grid reference for calculation of distance. Where a different Grid Reference Entry Point is to be considered by the Transporter from the original Grid Reference Entry Point provided.
GRID_REFERENCE_EXIT_POINT / O / T / 9 / 0 / Grid reference for calculation of distance. Where a different Grid Reference Exit Point is to be considered by the Transporter from the original Grid Reference Exit Point provided
DISTANCE / O / N / 4 / 1 / Distance calculated from SMP to NTS Entry Point.
SITE_COMPONENT_SOQ / M / N / 10 / 0 / The value used to calculate the rates where an SOQ value is required in the rate calculation. For an NTS site the MNEPOR value is populated. For a CSEP the CSEP_CONNECTION_MAX_SOQ value is populated. For an LDZ Direct Connect site the Nominated SOQ value is populated.
NTS_OPTIONAL_RATE / M / N / 10 / 4 / Rate to be applied
Total / 114

RT_U74_CSO_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. Value:U74
CSO_ORGANISATION_CODE / M / N / 3 / 0 / A 3 character short code, which uniquely identifies a Connected System Operator (CSO) Organisation.
CSO_NAME / M / T / 50 / 0 / Name of the Connected System Operator (CSO) Organisation Name.
CSO_CONTACT_TELEPHONE_NUMBER / M / N / 15 / 0 / Contact telephone number of the Connected System Operator (CSO) Organisation.
CSEP_ID / M / T / 8 / 0 / The unique identifier for the Connected System Exit Point.
CSEP_ADMIN_CHARGE_RATE / O / N / 10 / 4 / CSEP Daily Administration charge. CONTEXT: This is a Transporter admin charge for Connected System Operator (CSO) connections.
Total / 89

RT_U75_METER_ASSET_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. Value:U75
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
METER_SERIAL_NUMBER / M / T / 14 / 0 / The manufacturers meter serial number
METER_TYPE / O / T / 1 / 0 / DEFINITION: The type of meter. Values. R = Rotary. T = Turbine. D = Diaphragm of unknown material. L = Leather Diaphragm. S = Synthetic Diaphragm. U = Ultrasonic .Z = Unknown
METER_MODEL_SIZE / O / T / 10 / 0 / "DEFINITION: The Meter Model Size description for the meter (e.g. ""0"" to ""1000000"") depending on the type of the meter."
NETWORK_TYPE / O / T / 3 / 0 / Populated with the Network the site is located. Allowable Values : LDZ or NTS
MAC_METER_ASSET_CHARGE_I / O / N / 10 / 4 / Asset charge Installation Annual Rental charges applicable for the asset. Pence per day
MAC_METER_ASSET_CHARGE_M / O / N / 10 / 4 / Asset charge Maintenance Annual Rental charges applicable for the asset. Pence per day
MAC_METER_ASSET_CHARGE_P / O / N / 10 / 4 / Asset charge Provision Annual Rental charges applicable for the asset. Pence per day
CAC_CORRECTOR_ASSET_CHARGE_I / O / N / 10 / 4 / Volume convertors (Correctors) Installation charges. Pence per day
CAC_CORRECTOR_ASSET_CHARGE_M / O / N / 10 / 4 / Volume convertors (Correctors) Maintenance charges. Pence per day
CAC_CORRECTOR_ASSET_CHARGE_P / O / N / 10 / 4 / Volume convertors (Correctors) Provision charges. Pence per day
DAC_DRE_I / O / N / 10 / 4 / Daily Read Equipment Installation charges. Pence per Day
DAC_DRE_M / O / N / 10 / 4 / Daily Read Equipment Maintenance charges. Pence per Day
DAC_DRE_P / O / N / 10 / 4 / Daily Read Equipment Provision charges. Pence per Day
Total / 131

RT_U92_INTERCONNECTOR_CNF_RESPONSE

RECORD/FIELD_NAME
*Occurs Max 1* / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of response that this record represents.
VALUE : U92
OUTCOME_CODE / M / T / 2 / 0 / Details whether the request has been accepted or rejected by the Transporter.
VALUES: RF - Referred,RJ-Rejected.
SITE_NAME / O / T / 50 / 0 / The name of the site associated to the Supply Meter Point(s).
POSTCODE_OUTCODE / M / TN / 4 / 0 / Standard PAF outcode as defined in the PAF digest.
POSTCODE_INCODE / M / TN / 4 / 0 / Standard PAF incode as defined in the PAF digest.
METER_POINT_REFERENCESUPPLY_METER_POINT / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Supply Meter Point References will only be created for new services or when a service is relayed to a different position.
SUPPLY_POINT_CONFIRMATION_REFERENCE / O / T / 10 / 0 / A sequential number that uniquely identifies the Confirmation.
CONFIRMATION_EFFECTIVE_ DATE / M / D / 8 / 0 / The date on which ownership of the Supply Meter Point is requested to commence.FORMAT : YYYYMMDD
Total / 91

RT_S72_REJECTION_DETAIL

RECORD/FIELD_NAME
*Occurs Max 1* / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / DEFINITION: A code identifying the type of request that this record represents VALUE:S72
REJECTION_REASON / M / T / 8 / 0 / A reason for the rejection of the
original input request.
Total / 11

TR_Z99_STANDARD_TRAILER

RECORD/FIELD_NAME
*Occurs Max 1* / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifyng the type of information that this record represents: Z99
RECORD_COUNT / M / N / 10 / 0 / The number of detail records contained within the file. This should not include the Standard Header (A00) and Standard Trailer (Z99) but should include any file specific Headers and Trailers specified for this file type,.
Total / 13