R 301904Z SEP 97

FM CDR CECOM FT MONMOUTH //AMSEL-CG//

TO RUERMOC/CDR CECOM FT MONMOUTH //AMSEL-SF-SEP//

RUEADWD/SA PENTAGON WASHINGTON DC //SAAA// RUEAAMC/CDR

AMC ALEXANDRIA VA //AMCCG// RUDHAAA/CDRINSCOM FT

BELVOIR VA //IALOG-R// RUEAMTC/CDRMTMC FALLS CHURCH

VA //MTLO// RUEANEA/CDRUSACE WASHINGTON DC //CELD//

RUAGAMS/CDRUSAEIGHT SEOUL KOR //FKJ4//

RUERFCP/CDRUSARSO FT CLAYTON PM //S0CG/SOLG//

RUEASRB/CDRUSARC FT MCPHERSON GA //AFRC//

RUERHNB/CDRUSASOC FT BRAGG NC //AOLO// RUEASRB/CDR

FORSCOM FT MCPHERSON GA //AFLG-SME/FCJ4//

RUEAMDW/CDRMDW WASHINGTON DC //ANLG-LS//

RUEAAIA/CDR TRADOC FT MONROE VA //ATPL/ATBO-HM//

RUEANBA/CDR USACIDC WASHINGTON DC //CILO//

RUEAHIC/CDRUSARPAC FT SHAFTER HI //APLG//

RUFDAAU/CINCUSAREUR HEIDELBERG GE //AEAGD//

RUEARNG/CNGB ARLINGTON VA //NGB-ARL-M//

RUEARDA/CDRUSAMRDC FT DETRICK MD //SGRD-ZA//

RUSTCCT/CDRUSASDC ARLINGTON VA //CSSD-ZA//

INFO RUEADWD/DA WASHINGTON DC

/SARD-ZT/SARD-ZCS/SARD-ZP/SARD-ZR/SARD-ZS/SARD-

/SC/SARD-SM/DAAE-ZB/DAAE-LO/DAAR-OT/DACS-SF/DAIG-

/SD/DALO-AOC/DALO-SML/DALO-SMM/DAMO-DR/DAMO-FDV/

/DAMO-TRF/SGPS-PSP/JDPP-SAF/SAILE-ESOH/DAIM-MD/

RUCOPAW/COMNAVSAFECEN NORFOLK VA//47/30/312//

RUVAFMC/AFMC WRIGHT PATTERSON AFB OH //IGFG/LGS/LSO-LOP//

RUWTFBA/AFSA KIRTLAND AFB NM //SEG//

RUERRSA/CDRLOGSA REDSTONE ARSENAL AL //AMXLS-PS//

RUERGAR/CDRUSASC FT RUCKER AL //CSSC-S/CSSC-M/CSSC-Z//

AIG 9004

AIG 12588

AIG 12590

RUFDCOU/CDR200THTAMMC KAISERSLAUTERN GE //AERLA-MMC-MACCD//

RUAGAMS/CDR USFK SEOUL KOREA //FKSF//

RUEACMC/CMC WASHINGTON DC //LPP-2//

RUCKALC/CG MCLB ALBANY GA //848/820//

RUENAAA/CNO WASH DC //OP-04//

RUKLDAR/CDRUSASAC ALEXANDRIA VA //AMSAC//

RUERMMA/CDR ORDCENSCH APG MD//ATSL-CMT//

RUSTCCT/CDRUSASDC ARLINGTON VA //CSSD-SA-S//

RUFDAAU/CINCUSAREUR HEIDELBERG GE //AEAGA-S//

RUEAMDW/CDRMDW WASHINGTON DC //ANOS//

RUEANEA/CDRUSACE WASHINGTON DC //CESO//

RUEAAMC/CDR AMC ALEXANDRIA VA //AMCRE/AMCSF/AMCSM/AMCQA//

RUDHAAA/CDRINSCOM FT BELVOIR VA //IAPER-HS//

RUEANBA/CDR USACIDC WASHINGTON DC //CISP-PE//

RUEAMTC/CDRMTMC FALLS CHURCH VA //MTOP-OPS//

RUERSHA/CDRUSAMEDCOM FT SAM HOUSTON TX //MCSM//

RUSTSDC/CDRUSASSDC HUNTSVILLE AL //CSSD-ES-S

RUEASRB/CDR FORSCOM FT MCPHERSON GA //AFPI-SO/FCJ1-SO//

RUEAHIC/CDRUSARPAC FT SHAFTER HI //APSL//

RUERFCP/CDRUSARSO FT CLAYTON PM //SOSF//

RUERHNB/CDRUSASOC FT BRAGG NC //AOOS//

RUEAAIA/CDR TRADOC FT MONROE VA //ATBO-SO//

RUAGAMS/CDRUSAEIGHT SEOUL KOR //EASF//

RUEASRB/CDRUSARC FT MCPHERSON GA //AFRC-SA//

RUEARNG/CNGB ARLINGTON VA //NGB-AVN-S//

BT

UNCLAS

SUBJECT: GROUND PRECAUTIONARY MESSAGE (GPM-97-013), BA-5800/U (NSN:

6665-99-760-9742) LITHIUM SULFUR DIOXIDE BATTERIES.

A. REF MSG, AMSEL-SF-SEP, DTG 171952Z SEP 96, SUBJECT: GROUND

PRECAUTIONARY MESSAGE (GPM 96-012), BA-5800/U (NSN 6665-99-760-9742)

LITHIUM SULFUR DIOXIDE BATTERIES.

B. REF MSG, AMSEL-SF-SEP, DTG 311437Z MAR 97, SUBJECT: GROUND

PRECAUTIONARY MESSAGE (GPM 97-005), AN/PSN-11, NSN 5825-01-374-6643

AND AN/PSN-11(V) 1, NSN 5825-01-395-3513, PRECISION LIGHTWEIGHT GPS

RECEIVERS (PLGR).

1. DISTRIBUTION: NOTE THIS IS A GPM MESSAGE AND HAS NOT BEEN

TRANSMITTED TO YOUR SUBORDINATE UNITS. MACOM COMMANDERS WILL

IMMEDIATELY RETRANSMIT THIS MESSAGE TO ALL SUBORDINATE UNITS,

OR ACTIVITIES ELEMENTS AFFECTED OR CONCERNED. RETRANSMITTAL SHALL

REFERENCE THIS MACOM COMMANDERS WILL IMMEDIATELY VERIFY AND

RETRANSMIT THIS MESSAGE TO: CDR CECOM FT MONMOUTH

NJ//AMSEL-SF-SEP//.

2. PERSONAL NOTE FROM THE CG CECOM: IN LIGHT OF THE SERIOUS

NATURE OF RECENT INCIDENTS WITH BA-5800/U BATTERIES THAT RESULTED

IN INJURIES, I HAVE DECIDED TO REISSUE GUIDANCE PROVIDED IN OUR

PREVIOUS GPM. UNTIL OUR EVALUATION IS COMPLETED, THE GUIDANCE

BELOW IS THE BEST ADVICE WE CAN GIVE FOR AVOIDING ADDITIONAL

INJURIES. PLEASE MAKE SURE EVERYONE IN YOUR CHAIN OF COMMAND WHO

WORKS WITH THE BA-5800/U AND AN/PSN-11 RECEIVES THIS CRITICAL

SAFETY GUIDANCE.

3. PROBLEM DISCUSSION.

A. SUMMARY: THIS GPM IS INTENDED TO REITERATE REFERENCE A

MESSAGE AND PROVIDE ADDITIONAL GUIDANCE, AS A RESULT OF THE RECENT

VIOLENT VENTINGS OF BA-5800 BATTERIES. ALL THESE VIOLENT VENTINGS

OCCURRED BECAUSE OF IMPROPER USAGE OR DISPOSAL PROCESSING.

B. ITEMS AFFECTED:

(1) BA-5800/U, BATTERY, NON-RECHARGEABLE, LITHIUM SULFUR

DIOXIDE, NSN 6665-99-760-9742.

(2) AN/PSN-11, PRECISION LIGHTWEIGHT GLOBAL POSITIONING

SYSTEM RECEIVER (PLGR), NSN 5825-01-374-6643, LIN N95862.

(3) AN/PSN-11(V)1, PRECISION LIGHTWEIGHT GLOBAL

POSITIONING SYSTEM RECEIVER (PLGR), NSN 5825-01-395-3513, LIN N95862.

4. USER ACTIONS. THE FOLLOWING INFORMATION IS A REITERATION OF

REFERENCE A MESSAGE. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN

SERIOUS PERSONAL INJURY AND/OR EQUIPMENT DAMAGE:

A. AN/PSN-11 AND AN/PSN-11(V)1

(1) NEVER USE ANY BA-5800 BATTERY IN THE AN/PSN-11 OR

AN/PSN-11(V)1 WHEN CONNECTED TO EXTERNAL POWER. REMOVE THE BA-5800

BATTERY BEFORE CONNECTING EXTERNAL POWER.

(2) PERFORM THE FOLLOWING PROCEDURES TO CONNECT A BA-5800

POWERED PLGR TO EXTERNAL POWER (TM 11-5825-291-13 WILL BE MODIFIED

TO INCLUDE THESE PROCEDURES):

(A) TURN OFF PLGR BEFORE CONNECTING TO EXTERNAL

POWER.

(B) REMOVE THE BA-5800 BATTERY.

(C) PROTECT THE BATTERY. ENSURE BATTERY IS STORED SO

THAT THE TERMINALS CAN NOT BE SHORTED OR USE ELECTRICAL TAPE ACROSS

THE TERMINALS.

(D) CONNECT THE EXTERNAL POWER CABLE TO A PROPERLY

GROUNDED (PER REFERENCE B MSG) 9-32 VOLT DC POWER SOURCE OR CONNECT

THE AC POWER ADAPTER TO 110/220V 50/60 HZ POWER SOURCE.

(E) CONNECT THE EXTERNAL POWER CABLE OR AC POWER

ADAPTER TO THE PLGR.

(F) INSTALL THE PLGR IN THE MOUNT.

(G) TURN ON PLGR.

(3) PERFORM THE FOLLOWING PROCEDURES WHEN DISCONNECTING

THE PLGR FROM EXTERNAL POWER FOR OPERATION WITH THE BA-5800 BATTERY

(TM 11-5825-291-13 WILL BE MODIFIED TO INCLUDE THESE PROCEDURES):

(A) TURN OFF PLGR

(B) REMOVE PLGR FROM MOUNT.

(C) DISCONNECT EXTERNAL POWER CABLE OR AC POWER

ADAPTER.

(D) REMOVE ANY ELECTRICAL TAPE, DIRT, DEBRIS FROM

BA-5800 BATTERY AND INSTALL INTO PLGR.

(E) TURN ON PLGR.

(F) REPLACE BA-5800 BATTERY WITH A FRESH BATTERY IN

THE EVENT OF LOW POWER INDICATION.

B. BA-5800 BATTERIES. THE FOLLOWING STEPS MUST BE TAKEN TO

SAFELY DISPOSE OF BA-5800 BATTERIES:

(1) DO NOT PUSH THE COMPLETE DISCHARGE DEVICE (CDD)

IMMEDIATELY AFTER USE. RETURN BATTERY TO DESIGNATED BATTERY DISPOSAL

PERSONNEL (TO BE DESIGNATED BY UNIT COMMANDER) FOR DISPOSAL

PROCESSING.

(2) DESIGNATED PERSONNEL MUST CAREFULLY SLIT OR REMOVE THE

PROTECTIVE LABEL COVERING THE CDD. NEVER PIERCE THE CDD LABEL WITH

ANY OBJECT TO ACTIVATE THE CDD.

(3) GENTLY DEPRESS THE CDD WITH A SMALL SCREWDRIVER.

PUSH THE SCREWDRIVER IN A STRAIGHT DOWN MOTION UNTIL YOU HEAR A

SINGLE CLICK. DO NOT USE A KNIFE OR ANY SHARP OBJECT WHICH MAY CAUSE

DAMAGE DURING CDD ACTIVATION. NEVER TWIST ANY OBJECT IN THE CDD

SLOT.

(4) AFTER DEPRESSING THE CDD, PLACE THE BATTERIES IN A

SECURE WELL VENTILATED AREA ISOLATED FROM PERSONNEL AND SEPARATED

FROM OTHER HAZARDOUS MATERIAL.

(5) SEPARATE ALL DISCHARGING BATTERIES BY AT LEAST TWO

INCHES ON ALL SIDES.

(6) ALLOW THE BATTERIES TO SIT A MINIMUM OF FIVE DAYS FOR

COMPLETE DISCHARGE.

(7) AFTER 5 DAYS (ONE DAY LONGER IN TEMPERATURES BELOW 32

DEGREES FAHRENHEIT), THE BATTERY VOLTAGE MUST BE MEASURED. IF THE

VOLTAGE READING IS LESS THAN TWO VOLTS THE BATTERY MAY BE DISPOSED OF

AS NON REGULATED WASTE IN ACCORDANCE WITH LOCAL REGULATIONS. IF TWO

VOLTS OR GREATER, DEPRESS THE CDD A SECOND TIME AND WAIT AN

ADDITIONAL 5 DAYS OR DISPOSE OF AS HAZARDOUS WASTE. AFTER 5 DAYS

RECHECK THE BATTERY VOLTAGE. DISPOSE OF AS NON REGULATED WASTE IF

LESS THAN TWO VOLTS OR AS HAZARDOUS WASTE IF TWO VOLTS OR GREATER.

5. POCS: FOR QUESTIONS REGARDING THIS MSG:

A. SAFETY OFFICE POINTS OF CONTACT:

(1) MR. DAVID KIERNAN AT DSN 992-0084 EXT. 6447, OR CML

(732) 532-0084 EXT 6447; DATAFAX: DSN 992-6403, OR CML (732)

532-6403; MILNET ADDRESS: "".

(2) MR. PHILIP KLIMEK AT DSN 992-0084 EXT. 6437, OR CML

(732) 532-0084 EXT 6437; DATAFAX: DSN 992-6403, OR CML (732)

532-6403; MILNET ADDRESS: "".

B. POWER SOURCE TEAM POINT OF CONTACT FOR PQDRS, GENERAL

DISPOSITION INSTRUCTIONS, AND INCIDENT REPORTS, CONTACT MR PAT LYMAN

AT DSN 992-8824, OR CML (732) 532-8824; DATAFAX DSN 992-8940, OR CML

(732) 532-8940; MILNET ADDRESS: "".

BT