Flow Chart of Manufacturing Process &
Scheme of Testing
For House wiring CABLE
Raw Material
FR- PVC Aluminium/Copper
Specification Gravity Thermal Finish size Cond. Resistance
Stability loss of mass Wrapping & Tensile (For Aluminium)
T.S. & elongation annealing (For Copper)
(before & after)
BUNCHING/STRANDING
DIMENSIONS CONDUCTOR RESISTANCE & WEIGHT
CORE INSULATION
FINISH DIMENSIONS, THICKNESS, SPARK TESTING
MARKING DETAILS OVERALL DIAMETER FOR SINGLE CORE
LAYING UP
SEQUENCE & DIRECTION OF LAY
CIRCULARITY & DIA OVER LAID UP CORES
FINAL SHEATHING
FINISH EMBOSSING, CONCENTRICITY THICKNESS
OVERALL DIAMETER OVALTY
TESTING
ROUTINE TESTING TYPE TESTING
ON ALL CABLE LENGTHS ON SAMPLE FROM EACH SIZE & TYPE OF CABLES
TESTED OK CABLES
FINAL PACKING & SEALING