May 2016doc.: IEEE 802.11-16/0733r0

IEEE P802.11
Wireless LANs

802.11
Resolutions to CID #7207 and #7818
(relative to Draft 5.0)
Date: 2016-05-19
Author(s):
Name / Company / Address / Phone / Email
Ganesh Venkatesan / Intel Corporation / 2111 NE 25th Ave, Hillsboro, OR 97124 / 503 334 6720 /

CID 7207:

Editor: Edit the entries in the table contained in Cl. 6.3.57.2.2 as shown below.

Name / Type / Value / Description
Peer MAC Address / MAC Address / Any valid individual addressed MAC Address / The address of the peer MAC entity to which the Timing Measurement frame is sent.
Dialog Token / Integer / 1-255 / The dialog token to identify the Timing Measurement transactionframe.
Follow Up Dialog Token / Integer / 0-255 / The dialog token of a Timing Measurement frame which the current frame follows, or 0 if there is no such frame. See 11.24.5 (Timing measurement procedure).
t1 / Integer / 0-(232-1) / Set to tThe value of t1 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Follow Up Dialog Token, in units of expressed in 10 ns units, or null if the Follow Up Dialog Token is 0.
Max t1 Error / Integer / 0-255 / Maximum error in the t1 value expressed inin units of 10 ns units; see 9.6.15.3 (Timing Measurement frame format) , or null if the Follow Up Dialog Token is 0.
t4 / Integer / 0-(232-1) / Set to tThe value of t4 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Follow Up Dialog Token, in units of expressed in 10 ns units, or null if the Follow Up Dialog Token is 0.
Max t4 Error / Integer / 0-255 / Maximum error in t4 value expressed inin units of 10 ns units, or null if the Follow Up Dialog Token is 0.
Vendor Specific / A set of elements / As defined in 9.4.2.26 (Vendor Specific element) / Zero or more elements.

Editor: Edit the entries in the table contained in Cl. 6.3.57.3.2 as shown below.

Name / Type / Value / Description
Peer MAC Address / MAC Address / Any valid individual addressed MAC Address / The address of the peer MAC entity to which acknowledges the receipt of the Timing Measurement frame
Dialog Token / Integer / 1-255 / The dialog token to identify the Timing Measurement transactionframe.
t1 / Integer / 0-(232-1) / Set to tThe value of t1 (see Figure 6-16 (Timing measurement primitives and timestamps capture) for the Timing Measurement frame identified by the Dialog Token, in units of expressed in 10 ns units, or is null if the Dialog Token is 0.
Max t1 Error / Integer / 0-255 / Maximum error in the t1 value expressed in units of 10 ns units, or is null if the Dialog Token is 0.
t4 / Integer / 0-(232-1) / Set to tThe value of t4 (see Figure 6-16 (Timing measurement primitives and timestamps capture) for the Timing Measurement frame identified by the Dialog Token, in units ofexpressed in 10 ns units, or is null if the Dialog Token is 0.
Max t4 Error / Integer / 0-255 / Maximum error in t4 value expressed in 10 ns units, or is null if the Dialog Token is 0.

Editor: Edit the entries in the table contained in Cl. 6.3.57.4.2 as shown below.

Name / Type / Value / Description
Peer MAC Address / MAC Address / Any valid individual addressed MAC Address / The address of the peer MAC entity to which the Timing Measurement frame is sent.
Dialog Token / Integer / 1-255 / The dialog token to identify the Timing Measurement transactionframe.
Follow Up Dialog Token / Integer / 0-255 / The dialog token of a Timing Measurement frame which the current frame follows, or 0 if there is no such frame. See 11.24.5 (Timing measurement procedure).
t1 / Integer / 0-(232-1) / Set to tThe value of t1 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Follow Up Dialog Token,expressed in units of 10 ns units, or is null if the Dialog Token is 0.
Max t1 Error / Integer / 0-255 / Maximum error in the t1 value expressed in units of 10 ns units, or is null if the Dialog Token is 0.
t4 / Integer / 0-(232-1) / Set to tThe value of t4 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Follow Up Dialog Token,expressed in units of 10 ns units, or is null if the Dialog Token is 0.
Max t4 Error / Integer / 0-255 / Maximum error in t4 value expressed in units of 10 ns units, or is null if the Dialog Token is 0.
t2 / Integer / 0-(232-1) / Set to tThe value of t2 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Dialog Token,expressed in units of 10 ns units, or is null if the Dialog Token is 0.
Max t2 Error / Integer / 0-255 / Maximum error in t2 value expressed in units of 10 ns units, or is null if the Dialog Token is 0.
t3 / Integer / 0-(232-1) / Set to tThe value of t3 (see Figure 6-16 (Timing measurement primitives and timestamps capture)) for the Timing Measurement frame identified by the Dialog Token, expressed in units of 10 ns units, or is null if the Dialog Token is 0.
Max t3 Error / Integer / 0-255 / Maximum error in t3 value expressed in units of 10 ns units, or is null if the Dialog Token is 0.
Vendor Specific / A set of elements / As defined in 9.4.2.26 (Vendor Specific element) / Zero or more elements.

CID 7818:

10.24.10 GCR block ack

10.24.10.1 Introduction

Subclause 10.24.10 (GCR block ack) extends the block ack mechanism to group addressed frames that are transmitted using the GCR block ack retransmission policy. Other than the exceptions noted in 10.24.10.2 (Scoreboard context control during GCR block ack) through 10.24.10.3 (GCR block ack BlockAckReq and BlockAck frame exchanges), the operation of GCR block ack is the same as is described in 10.24.7 (HT-immediate block ack extensions).

Submissionpage 1Ganesh Venkatesan, Intel Corporation