SWARNANDHRA COLLEGE OF ENGINEERING & TECHNOLOGY
(Approved by AICTE, Accredited by NBA, Affiliated to JNTU, KAKINADA)
SEETHARAMPURAM,NARSAPUR-534280.W.G.DT.,
DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING
Faculty Name: Mr.Ch.VENKATESWARA RAO
Class: IV B-Tech(EEE-A&B)
Subject: H.V.E
MID-II
UNIT-5
1. A) What is Rogowski Coil? Explain with a neat diagram its principle of operation for measurement of high impulse currents. M[10]
B) A Rogowski coil is required to measure impulse current of 8 kA having rate of change of
current of 1010 A/sec. The voltmeter is connected across the integrating circuit which reads 8 volts for full scale deflection. The input to the integrating circuit is from the Rogowski Coil. Determine the
mutual inductance of coil R and C of the integrating circuit. M [10]
2. What are the requirements of a sphere gap for measurement of high voltages? Discuss the disadvantages of sphere gap for measurements. M [20]
3. A) Discuss various methods of measuring high impulse currents. M [12]
B) A peak reading voltmeter is required to measure voltage upto 150 kV. The peak voltmeter
uses an RC circuit, a microammeter and a capacitance potential divider. The potential divider has a
ratio of 1200 : 1 and the micrometer can read upto 10 μA. Determine the value of R and C if the time
constant of RC circuit is 8 secs. M [8]
4. A) What are the problems associated with measurement of very high impulse voltages? Explain how these
can be taken care of during measurements. M [12]
B) An absolute electrostatic voltmeter has a movable circular plate 8 cms in diameter. If the
distance between the plates during a measurement is 4 mm, determine the potential difference when the force of attraction is 0.2 gm wt. M[8]
5. Write a short notes on
A) surge recorder M[10]
B) voltage divider M[10]
6. A) A generating voltmeter is required to measure voltage between 15 kV to 250 kV. If the
indicating meter reads a minimum current of 2 μA and maximum of 35 μA, determine the capacitance of the generating voltmeter. Assume that the speed of driving synchronous motor is 1500 rpm. M [10]
B) Determine the breakdown voltage for air gaps of 2 mm and 15 mm lengths under uniform
field and standard atmospheric conditions. Also, determine the voltage if the atmospheric pressure
is 750 mm Hg and temperature 35°C. M [10]
UNIT-6
1.Give the mathematical models for lighting discharge & explain them. M[20]
2 . how a fault can produce an over volage in system, explain with a necessary proof ? M[20]
3. explain the importance of switching over voltage in EHV power systems. How is protection against over voltages achieved? M[20]
4. explain with suitable figures the principles & functioning of
a) Expulsion gaps M[10]
b) protector tubes
M[10]
5.Discuss the power frequency over voltage in power systems. Explain various protection schemes
Employed to suppress the over voltages. M[20]
6. A surge of 100 kV travelling in a line of natural impedance 600 ohms arrives at a
junction with two lines of impedances 800 ohms and 200 ohms respectively. Find the surge voltages
and currents transmitted into each branch line. M[20]
UNIT-VII
1) Explain the operation of high voltages Schering Bridge when the test specimen is grounded. M[20]
2) How the dielectric constant and loss factor of an insulating material can Be measured under high voltage condition at power frequency? Draw the necessary circuit diagram. M[20]
3) Briefly explain the method used for calibrating the partial discharge detectors. M[20]
4) Describe how a fault in a long cable can be detected and located using partial discharge technique. M[20]
5) Write a short note on the measuring impedance circuit for the estimation of practical discharge. M[20]
6) Describe Mole’s arrangement for measuring high dissipation factors in the low frequency range. M[20]
UNIT-VIII
1) Explain the following technologies often used in high voltage testing. M[20]
i) Disruptive discharge voltage
ii) Withstand voltage
iii) 100% flashover voltage
iv) Creepage distance
2) List out the various tests to be carried out on insulator. M[20]
3) Explain various tests to be carried out on a bushing. M[20]
4) List out the various tests to be carried out on a cable. M[20]
5) Explain with a schematic diagram method of measuring RIV of transmission line hardware. M[20]
6) Describe the impulse current tests performed on lightning arrestors. M[20]
Prepared by verified by HOD Dept of EEE