ROOM DATA SHEET
LEARNING INNOVATION BUILDING
BUILDING No. 17
THE UNIVERSITY OF QUEENSLAND
Revision: 001 / Date: 20/08/2009 / Sheet No:DEPARTMENT:
PART A : PHYSICAL REQUIREMENTS
1.0 ROOM DESCRIPTION
1.1 Room Name(s): / Lounge / Level(s):41.2 Room Number(s): / 421
1.3 No. of Rooms of This Type: / 1
1.4 Room Function/s: / Activity: / Method of Operation:
Meetings, waiting, group work
1.5 No. of Occupants: / 0
1.6 Hours of Use:
1.7 Room Size: / W x D x H or UFA sq.m.
Additional Notes:
2.0 ROOM FINISHES
2.1 WallsFinish / Plasterboard, painted
glass walls to offices
Bi-fold wall to temporarily separate the area from the Innovation Lab
Special Requirements
2.2 Floor
Finish / carpet
Special Requirements
2.3 Ceiling
Finish / Exposed concrete soffits in front of the offices
Suspended plasterboard ceiling in the centre of the space
Special Requirements
2.4 Skirting
Type / Extruded Aluminium Skirting 100mm high
Special Requirements
2.5 Doors
Type
Hardware
Viewing Panel
Signage
2.6 Acoustics
Requirements: / Refer to Acoustic Engineer reports
Additional Notes:
PART B : SERVICES REQUIREMENTS
3.0 HYDRAULIC SERVICES
Fitting / Water (Hot) / Water (Warm) / Water (Cold) / Outlet/Requirements3.1 Basins / NA
3.2 Sinks / NA
3.3 Showers / NA
3.4 Water Closets / NA
3.5 Urinals / NA
3.6 Drinking Fountain / NA
3.7 Dish Washer / NA
3.8 BHW Unit / NA
3.9 Other
4.0 MECHANICAL SERVICES
4.1 Air Conditioned / yes4.2 Mechanical Ventilation
4.3 Natural Ventilation / yes
4.4 Special Requirements / Local After hours Control: / Local set point control:
Local on/off control: / Continual supply – main system AND backup system required:
Other:
4.5 Hours of Operation
4.6 No. of computers
4.7 Other Equipment/Heat Load
5.0 LIGHTING
5.1 General Illumination / 160 lux5.2 Activities requiring Special Lighting / Desk / Lighting Level Required:
320 lux
5.3 Dimmer Control / Yes
5.4 Special Switching Requirements / Occupancy Sensor and Timer
5.5 Other Requirements
6.0 POWER
Type / No. / Protection / Location/Related Equipment/Comment6.1 General GPO’s / 5 x double
1 x single / 1 phase, 10A, RCD / 2 x double in floor box
1 x double ceiling mounted, Data Projector
Cleaners
6.2 Special GPO’s
6.3 Other Requirements / 2 x Floor Boxes
7.0 COMMUNICATION
Type / No. / Comment7.1 Telephone
7.2 Computer Outlet / 2 x double
1 x single / 1 x double in floor box
1 x double ceiling mounted, Data Projector
7.3 Printer Terminal
7.4 Televisions Points
7.5 Facsimile
7.6 Internet Connection
7.7 Audio-visual Equipment / 1 / Data Projector
7.8 PA Requirements
7.9 Other
8.0 SECURITY
8.1 Access / Secure / Non-secure8.2 Intruder Alarm Requirement
8.3 CCTV Requirement
8.4 Comment
9.0 EQUIPMENT AND FIXTURES
Type / No. / Comment9.1 Photocopier
9.2 Waste Bin/Refuse Disposal Requirements
9.3 Printer
9.4 Pin Board
9.5 White Board
9.6 Curtains, Blinds
9.7 Filing Cabinets
9.8 Overhead Projector/ Screen
9.9 Display Racks
9.10 Refrigerator
9.11 Microwave
9.12 Other
PART C : FIXED AND LOOSE FURNITURE
10.0 LOOSE FURNITURE
Type / No. / Comment10.1 Chairs / 6 / Lounge chairs
10.2 Tables / 1 / Coffee table
10.3 Work Stations / 0
10.4 Other
11.0 BUILT-IN JOINERY
Type / Description / Comment and Special Finishes11.1 Reception counter unit / NA
11.2 Desk height workbench
11.3 Underbench cupboards
11.4 Overbench cupboards / NA
11.5 Full Height Storage Cupboards / NA
11.6 Shelving
11.7 Any special ancillary storage requirements / NA
11.8 Lockers / NA
11.9 Bench seating / NA
11.10 Other
12.0 AUTHORISATION
Signature / Position / DateINSTRUCTIONS FOR COMPLETION
1.1 Write in room or area name.
1.2 To be completed once sketch plans are finalised.
1.3 Number of this type of room throughout the total project.
1.4 Write in all functions likely to occur in the room and describe the manner in which these functions are undertaken.
1.5 Estimate maximum number of occupants for each activity undertaken within the room.
1.6 Also note any out-of-hours use.
1.7 Provide minimum internal height and either plan dimensions or minimum usable floor area.
2.1 Note any specific requirements – glazed panels/partitioning, sliding/retractable partitioning, viewing panels, paint, tiles, splashbacks, any particularly hard-wearing requirements.
2.2 Note preference and requirements for finishes - carpet, vinyl, tiles (noise reduction, cleaning ability, durability, etc.)
2.3 Note preference and requirements for finishes (noise reduction, dust-free etc.)
2.4 Also note ducted skirting if required.
2.5 Note any specific widths, type (double, single door and a half), heights. Note any special locks on doors, electronic locking systems, or card reader access, if required.
2.6 Note acoustic requirement e.g. privacy, to prevent noise breakout, internal acoustic quality.
3.0 Note any fixtures and the numbers required to the area, whether hot and cold water are required, whether fixtures are preferred as stainless steel or vitreous china, and any specific requirements. Note any special requirements to taps – elbow or foot control or automatic.
4.0 Note if AC is required for comfort or particular requirements, whether any equipment to the area has a heat load, if there is a preferred temperature for the room, or if there are any special requirements related to supply or control.
5.0 Note if any spotlighting is require to a particular area for a special purpose, activity or piece of equipment within the room. Do the various activities within the room require differing alternative levels of light or differing sets of controls for lights?
6.0 Note number of points required, any 3 phase or 15 amp outlets required, the need for emergency power or a continuous power supply, or the need for ceiling mounted equipment. 1 Phase/10amp are the standard outlets that will be provided.
7.0 Note whether digital or analogue, number of points and handsets, and any other specific requirements.
8.0 Note any requirements including whether wireless data is required.
9.0 Note requirements and any preferred characteristics to the items. Note requirement for curtains/blinds e.g. anti-glare, dim-out, blackout. Also note any projection screens or blinds that need to be motorised.
10.0 Note any specific requirements.
11.0 Note any specific requirements.