Québec, Québec G1K 9H4, Canada
Phone (418) 877–2944
Fax (418) 877-2834 or (418) 266–1422
Dernière révision du modèle de document PSR: 15 janvier 2003
ARIES
ARIES Airborne Radiometer Evaluation System
ARIES End Item Data Package
Document Number: / BOM-ARIES-0006 / Issue Date: / 7November2006Issue: / 1 / Revision: / –
Distribution: / See page iv / Classification: / N/A
Function / Name / Signature / Date
Prepared by / Electronics Designer / Jean-Yves Trottier
Checked by / Electronics Lead / Mario Lehoux
Approved by / Project Manager / Robert Poulin
PROPRIETARY
The information contained herein is proprietary to and should be considered a trade secret of ABBBomem Inc. It shall not be reproduced in whole or in part without the written authorization of ABBBomem Inc.
3BOM000034D0010 rev C
PR-2100-FO
ABB / ARIESARIES End Item Data Package / Document No:BOM-ARIES-0006
Issue: 1Rev:–Page
Date: 7November20061
Table of Contents
1.Introduction......
1.1Purpose of Document......
1.2Scope
1.3Bibliography
1.3.1Applicable Documents
1.3.2References......
1.4Acronyms......
1.5Definitions......
2.Electrical Modification......
2.1Power Supply Plate......
2.1.1Modification details......
2.1.2Mechanical Aspect......
2.1.3Power Supply Plate Schematics......
2.2Optical Head......
2.2.1Modification details......
2.2.2Mechanical Aspect......
2.2.3Feedthrough......
2.2.4Optical Head Schematics......
2.3External Harnessing......
2.3.1Modification details......
2.3.2Mechanical Aspect......
2.3.3External Harnessing Schematics......
3.Material List......
List of Figures
Figure2–1...... Power Supply Unit Diagram
Figure2–2...... Fuse Enclosure
Figure2–3...... Power Supply Unit Relay
Figure2–4...... Power Supply Unit PS1
Figure2–5...... Power Supply Unit PS2
Figure2–6...... Power Supply Unit PS3-4-5
Figure2–7...... AW50D/15-A Wiring
Figure2–8...... Interconnections Rework
Figure2–9...... Optical Head Diagram
Figure2–10...... Optical Head Thermal Control
Figure2–11...... IO Modules
Figure2–12...... Optical Head FTB
Figure2–13...... Bloc Diagram
Figure2–14...... ADC #1
Figure2–15...... ADC #2
Figure2–16...... Metrology
Figure2–17...... Scan Amplifier Drive
Figure2–18...... Scan Amplifier Power
Figure2–19...... Ethernet
Figure2–20...... Laser
Figure2–21...... Motor #1
Figure2–22...... Motor #2
Figure2–23...... Power & White Light
Figure2–24...... Quadrature
Figure2–25...... White Light
Figure2–26...... RS-232
Figure2–27...... RS-422
Figure2–28...... RS-485
Figure2–29...... Temperature Sensor & I.D. Tag
Figure2–30...... P103-P106 Harness
Figure2–31...... P104-P107 & P102-P105 Harness
List of Tables
Table2–1...... Feedthrough wiring
Table4–1...... Upgrade Material List
Document Change Record
Issue / Rev. / Date(yy-mm-dd) / Prepared by / Change Description
1 / – / 06-11-09 / Jean-Yves Trottier / First release.
Distribution List
The following persons (or company) shall receive this document:
Project Team
Client
Other
ABB / ARIESARIES End Item Data Package / Document No:BOM-ARIES-0006
Issue: 1Rev:–Page
Date: 7November20061
1.Introduction
1.1Purpose of Document
This documentation package is a bundle of all the information used and generated forthe ARIES instrument upgrade of summer 2006.
The purpose of the upgrade was to renew electronic and software of the instrument using ABB Bomem actual technology.
1.2Scope
1.3Bibliography
1.3.1Applicable Documents
AD1
1.3.2References
Ref.1Author, Title (italic style), Edition, Press, Year
Ref.2R. N. Bracewell, The Fourier Transforms and Its Applications, Second Ed. Revised, McGraw-Hill Publishing Co., New-York, 474 p., 1986
1.4Acronyms
BSR/CPBeam Splitter-Recombiner/Compensator Plate
BBBlack Body
FFTFast Fourier Transform
FOVField of View
FWHMFull Width at Half Maximum
IGMInterferogram
ILSInstrument Line Shape
INTInterferometer
IRInfra Red
LOSLine Of Sight
MCTMercury Cadmium Telluride
NESRNoise Equivalent Spectral Radiance
OPDOptical Path Difference
RMSRoot Mean Squared
SNRSignal-to-Noise Ratio
SPCSpectrum
ZPDZero Path Difference
TBCTo Be Confirmed
TBDTo Be Determined
TBRTo Be Reviewed
1.5Definitions
Word:Word Definition
2.Electrical Modification
2.1Power Supply Plate
2.1.1Modification details
The Power Supply Plate modification consists of removing the CEM0302G (ARIES Power Cube Assembly) that is not used any more and to replace the Abbott power supply AM50T/5/15-A (PS2) by an Abbott AW50D/15-A. These modifications are required to fulfill power requirements of the new electronics.
2.1.2Mechanical Aspect
The new Abbott power supply is installed at the same location as the old one, as it is slightly smaller, new mounting holes have been drilled into the holding plate.
A terminal bloc (TB5) has been mounted where the CEM0302G box was located, this one serves to bridge the two outputs of the power supply in a bipolar output and to connect remote sense terminals.
2.1.3Power Supply Plate Schematics
2.1.3.1Updated original drawings
The following drawings are original 1994 schematics, hand updated to reflect actual modified system:
- Power Supply Unit Diagram
- Fuse Enclosure
- Power Supply Unit Relay
- Power Supply Unit PS1
- Power Supply Unit PS2
- Power Supply Unit PS3-4-5
See next page for:
Figure2–1Power Supply Unit Diagram
See next page for:
Figure2–2Fuse Enclosure
See next page for:
Figure2–3Power Supply Unit Relay
See next page for:
Figure2–4Power Supply Unit PS1
See next page for:
Figure2–5Power Supply Unit PS2
See next page for:
Figure2–6Power Supply Unit PS3-4-5
2.1.3.2New drawings (Power Supply Plate)
The following drawings are new schematics made especially for the upgrade:
- AW50D/15-A Wiring
- Interconnections Rework
See next page for:
Figure2–7AW50D/15-A Wiring
See next page for:
Figure2–8Interconnections Rework
2.2Optical Head
2.2.1Modification details
The Optical Head modification consists of removing the major part of the electronics in the instrument and associated computer:
- SEC0400G Metrology board.
- SEE0200G Power amplifier board.
- SEK3100G Servo control board.
- SEK3200G Communication board.
- SEK3300G Fiber optic interface.
- SEK3400G ADC board (2X)
- SEQ3200G DSP96002 data crunch
- SEQ3300G PC communication board
- SEQ3400G 64MB dram extension board
And of replacing it with an actual electronic board set consisting of:
- SEE0600G High power drive board
- 0002-11-2-00002-01 Digital control module model -A
- 0002-07-2-00001-01 Science module model - A (2X)
- 0002-13-2-00001-01 Metrology module model - A
- 0002-13-2-00001-01 Temp. sensor & I.D. tag module model - A
Also, the laser and its power supply are actualised to the following components:
- AA000566-01 L28120AL3747 PS Laser DC 1450Vout 4.5mA
- 05LHP900 Laser M.G. 4.5mA anode output
Because of the non availability of a compatible RS-485 link on the Digital Control Module, all I/O modules were replaced with their RS-232 counterpart.
- D1132 Voltage input module 5V=>D1131
- D1412 RTD 0.00385 100 input module=>D1411
- D1452 (2X) Thermistor 2252 input module=>D1451
2.2.2Mechanical Aspect
To avoid modifying Optical Head chassis and lower the risk causing pressure leak, some mounting plates were used to adapt new boards to existing holes pattern. The description and schematic of these adapters can be found in MECHANICAL MODIFICATION section.
The laser substitution required a new bracket design as the new one is actually smaller. Once again, you will find related information in MECHANICAL MODIFICATION section.
2.2.3Feedthrough
This is the after upgrade Feedthrough assignation:
Table2–1Feedthrough wiring
A1 / ETHERNET TX+ / B1 / NC / C1 / RS-422 RX+A2 / ETHERNET TX- / B2 / NC / C2 / RS-422 RX-
A3 / ETHERNET RX+ / B3 / NC / C3 / SHIELD (RS-422)
A4 / ETHERNET RX- / B4 / NC / C4 / RS-422 TX-
A5 / SHIELD (ETHERNET) / B5 / +28VL / C5 / RS-422 TX+
A6 / NC / B6 / 28VLRTN / C6 / RS485- (WATLOW)
A7 / NC / B7 / +24VM1 / C7 / RS485+ (WATLOW)
A8 / +15VIN1 / B8 / 24VM1RTN / C8 / SHIELD (RS-422)
A9 / 15VIN1RTN / B9 / +24VM2 / C9 / NETWBOOT
A10 / -15VIN1 / B10 / 24VM2RTN / C10 / OUTPUT FAN (+)
A11 / +15VIN2 / B11 / +12VT / C11 / OUTPUT FAN (-)
A12 / 15VIN2RTN / B12 / 12VTRTN / C12 / SHIELD
A13 / -15VIN2 / B13 / SHIELD / C13 / OUTPUT HEATER (-)
A14 / SHIELD / B14 / NC / C14 / OUTPUT HEATER (+)
A15 / NC / B15 / NC / C15 / SHIELD (WATLOW)
2.2.4Optical HeadSchematics
2.2.4.1Updated original drawings
The following drawings are original 1994 schematics, hand updated to reflect actual modified system:
- Optical Head Diagram
- Optical Head Thermal Control
- IO Modules
- Optical Head FTB
See next page for:
Figure2–9Optical Head Diagram
See next page for:
Figure2–10Optical Head Thermal Control
See next page for:
Figure2–11IO Modules
See next page for:
Figure2–12Optical Head FTB
2.2.4.2New drawings (Optical Head)
The following drawings are new schematics made especially for the upgrade:
- Bloc Diagram
- ADC #1
- ADC #2
- Metrology
- Scan Amplifier Drive
- Scan Amplifier Power
- Ethernet
- Laser
- Motor #1
- Motor #2
- Power & White Light
- Quadrature
- White Light
- RS-232
- RS-422
- RS-485
- Temperature Sensor & I.D. Tag
See next page for:
Figure2–13Bloc Diagram
See next page for:
Figure2–14ADC #1
See next page for:
Figure2–15ADC #2
See next page for:
Figure2–16Metrology
See next page for:
Figure2–17Scan Amplifier Drive
See next page for:
Figure2–18Scan Amplifier Power
See next page for:
Figure2–19Ethernet
See next page for:
Figure2–20Laser
See next page for:
Figure2–21Motor #1
See next page for:
Figure2–22Motor #2
See next page for:
Figure2–23Power & White Light
See next page for:
Figure2–24Quadrature
See next page for:
Figure2–25White Light
See next page for:
Figure2–26RS-232
See next page for:
Figure2–27RS-422
See next page for:
Figure2–28RS-485
See next page for:
Figure2–29Temperature Sensor & I.D. Tag
2.3External Harnessing
2.3.1Modification details
All electrical modifications to external harnessing are listed and explained in the document “BOM-ARIES-0005 ARIES Electrical ICD”.
2.3.2Mechanical Aspect
A bracket is added to hold the new Ethernet connector J125 and the new RS-422 connector J124, see “MECHANICAL MODIFICATION” section for details.
The optical fibers previously used for data communication are completely removed from the system, only the two sealed connectors remain on the Optical Head module. These were plugged with an appropriate SMA cap.
2.3.3External HarnessingSchematics
2.3.3.1Updated original drawings
The following drawings are original 1994 schematics, hand updated to reflect actual modified system:
- P103-P106 Harness
- P104-P107 & P102-P105 Harness
See next page for:
Figure2–30P103-P106 Harness
See next page for:
Figure2–31P104-P107 & P102-P105 Harness
2.3.3.2New drawings (External Harnessing)
New schematics made especially for the upgrade are found in BOM-ARIES-0005 ARIES Electrical ICD.
3.Material List
Here is the list of items added to the instrument for the upgrade:
Table3–1Upgrade Material List
Description / ABB's P/N / QTY / Supplier / Vendor's P/NComputers
Rhino D820 laptop 2000 MHz 15.4" WSXGA+ / AA003188-01 / 2 / EmperorLinux
WinXP / 2
Electronic parts
Military AC-DC power supply ±15V 1.67A / AA003128-01 / 1 / Martek Power / AW50D/15-A
Voltage input RS-232 module ±5V / AA003110-01 / 1 / D1131
Thermistor 2252 Ohms Input, RS-232 / D1451 / 2 / D1451
RTD .00385 100 Ohms Input, RS-232 / M1411 / 1 / D1411
L28120AL3747 PS Laser DC 1450Vout 4.5mA / AA000566-01 / 1 / 9-0027-0788-0-0
Laser M.G. 4.5mA anode output / 05LHP900 / 1 / 05LHP900
RJ45 in line metal receptacle IP67 / AA003187-01 / 1 / Mouser / RJF2PEM1G
Ethernet Plug Connector Green / AA000525-01 / 1 / RJF6MG
100ft CAT5 Xover Shield Ether Grey Cable / AA000886-01 / 2 / CBCC235263-100
Feed through 15 pins / 200B0066 / 1 / 030-092-0126
Electronic assemblies
Digital Control Module Model-A / 0002-11-2-00002-01 / 1 / Bomem / N/A
MRXS High Power Drive Board / SEE0600G / 1 / Bomem / N/A
MRXS EMI Box ADC Stick Ass'y / 0002-10-2-00012-01 / 2 / Bomem / N/A
MRXS Metrology Module Model-A / 0002-06-2-00001-02 / 1 / Bomem / N/A
Temp. Sensor & I.D. Tag Module Model-A / 0002-13-2-00001-01 / 1 / Bomem / N/A
Cables assemblies
ARIES Metrology Harness / 0008-18-2-00004-01 / 1 / Connexion Technic / N/A
ARIES Scan AMP Drive Harness / 0008-18-2-00002-01 / 1 / Connexion Technic / N/A
ARIES ADC #1 Harness / 0008-18-2-00001-01 / 1 / Connexion Technic / N/A
ARIES ADC #2 Harness / 0008-18-2-00003-01 / 1 / Connexion Technic / N/A
Military connectors
Circ.Conn Box MountRecept 4 Sockets / K2E84S / 1 / PEI-Genesis / KPT02E8-4S
Circ. Plug Shell#8 4 Pin Contacts / K6F84P / 2 / PEI-Genesis / KPT06F8-4P
Metal Dust Cap Shell Size 8 / AA003189-01 / 1 / PEI-Genesis / MS3181-8C
Circ.Conn Box MountRecept 6 Sockets / AA003190-01 / 1 / PEI-Genesis / KPT02E10-6S
Circ. Plug Shell#10 6 Pin Contacts / K6F106P / 1 / KPT06F10-6P
MS3116F10-6P
Mechanical parts
0-LASER MOUNT PLATE-M.100 / SMC0101G / 2 / Bomem / SMC0101G
"O"-RING #121 BUNA-N / IMZ1121B / 2 / Bomem / 121 BUNA-N
BA - Thermal Plate - BMXS Board - MRXS / AA000598-01 / 1 / Bomem / N/A
0 - Metrology Board Support / SMC1802G / 1 / Bomem / N/A
SMA protective cap with chain / 905-163 / 2 / Bomem / 905-163
Modified Thermal Pad / AA000407-01 / 1 / Bomem
SPACER HEX.ALUMINUM 4-40 X 1/2 / IMZ0594 / 5 / Bomem
POWER AMP HEATSINK AND ADAPTOR (ARIES) / AA003197-01 / 1 / Qualitech / N/A
COMM. CONNECT. HOLDER (ARIES) / AA003198-01 / 1 / Metaux Presses
— End of document —