SECTION 07 13 26
UNDERSLAB WATERPROOFINGWITH NON-CHEMICAL TERMITE BARRIER
************************************************************************************************************************
This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction documents for Underslab insect barrier and waterproofing membrane systems. Polyguard® TERM® UnderslabBarrier is used as a waterproofing membrane/vapor barrier to virtually eliminate water and vapor transmission through concrete slabs on grade. In addition to protecting floor finishes and indoor air quality, TERM®UnderslabBarrier also acts as a barrier to insects, pesticides, methane gas and radon gas.
Edit entire master to suit project requirements. Modify or add items as necessary. Delete items which are not applicable. Words and sentences may contain a choice to be made regarding inclusion or exclusion of a particular item or statement. This section may include performance, proprietary and descriptive type specifications. Edit to avoid conflicting requirements. Editor notes to guide the specifiers are included between lines of asterisks to assist in choices to be made. Remove these notes before final printing of specification.
This guide specification is written around the Construction Specifications Institute (CSI) Section Format standards.
For specification assistance on specific product applications, please contact our offices above or any of our local product representatives throughout the country.
Polyguard Products Inc. reserves the right to modify these guide specifications at any time. Updates for this guide specification will be posted on the manufacturer’s web site and/or in printed matter as they occur. Manufacturer makes no expressed or implied warranties regarding content, errors, or omissions in the information presented.
************************************************************************************************************************
PART 1 GENERAL
1.01SECTION INCLUDES
A.Surface preparation.
B.Application of underslab barrier system.
C. Accessory Products
1.02RELATED SECTIONS
************************************************************************************************
Specifiers Notes: Edit the list of related sections as required for the project. List other sections dealing with work directly related to this section.
************************************************************************************************
A.Section 0330 00 - Cast-in-Place Concrete.
B.Section 07 21 00 – Thermal Insulation.
C.Section 07 60 00 – Flashing and Sheet Metal.
D. Section 07 92 00 – Joint Sealants.
E.Section 33 46 00 - Sub drainage.
1.03REFERENCES
A.ASTM D4632 - Standard Test Method for Grab Breaking Load and Elongation of Geotextiles
B. ASTM D412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers- Tension.
C. ASTM D570 - Standard Test Method for Water Absorption of Plastics.
D.ASTM E96 (Method B) - Standard Test Methods for Water Vapor Transmission of Materials.
E.ASTM E154- Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover.
F. ASTM D882 - 02 Standard Test Method for Tensile Properties of Thin Plastic Sheeting
G. ASTM F2130 - 01 Standard Test Method for Measuring Repellency, Retention, and Penetration of Liquid Pesticide Formulation Through Protective Clothing Materials
H. ASTM D1876 - 00 Standard Test Method for Peel Resistance of Adhesives (T Peel Test)
I.ASTM D1434 - Test Method for Determining Gas Permeability Characteristics of Plastic Film and Sheeting.
J. General Services Administration, Public Building Service: GSA-PBS-07115 Guide
Specification for Elastomeric Waterproofing.
K. ASTM D6574 - 00 Test Method for Determining the (In Plane) Hydraulic Transmissivity of a Geosynthetic by Radial Flow
L.Radon Reduction Technology Laboratory - Resistance to Permeance by Radioactive Radon Gas; Resistance to Diffusion by Radioactive Radon Gas.
M. ASTM D903 - 98 Standard Test Method for Peel or Stripping Strength of Adhesive Bonds.
N.ASTM C836 - 06 Standard Specification for High Solids Content, Cold Liquid Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course.
O. ASTM D1970 - 01 Standard Specification for Self Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection
P. ASTM D4716 - 01 Test Method for determining the (In plane) Flow Rate per Unit Width and Hydraulic Transmissivity of a Geosynthetic Using a Constant Head.
Q. ASTM D5385 - 93(2006) Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes.
R.ASTM D1758 – 06 – Standard Test Method for Evaluating Wood Preservatives
1.04SUBMITTALS
A.Product Data: Submit manufacturer’s product data, installation instructions, use limitations and recommendations. Include certification of data indicating VOC (Volatile Organic Compound) content of all components of waterproofing system.
B. Samples: Submit representative samples of the following for approval:
1.UnderslabBarrier
2.Barrier Tape and Accessories.
C.Sustainable Design Submittals:
1.Submit invoices and documentation from manufacturer of the amounts of materials and content for products specified.
2.Submit invoices and documentation showing manufacturing locations and origins of materials for products manufactured and sourced within 500 miles of project location.
D. LEED Submittal: Documentation of materials, recycled content and location of manufacturer.
1.LEED MR Credit 2 – Construction Waste Management: Provide documentation of reusable materials by weight and volume diverted back to manufacturing process or to appropriate sites.
2.LEED, MR Credit 5 – Regional Materials: Provide documentation for cost of materials or products that have been extracted, harvested, or recovered and manufactured within 500 miles of project site.
a.If only a portion of the materials or products is extracted, harvested, or recovered and manufactured locally, then only provide percentage by weight for credit value.
3. LEED, SS Credit 3 – Brownfield Development: Provide documentation of materials that contribute to the redevelopment of a contaminated land site that has been defined as a brownfield by a local, state or federal government agency.
4.LEED, EQ Credit 5 – Indoor Chemical and Pollutant Source Control: Provide documentation of long term testing of ability to physically block access by termites and other insects into the structure, thus reducing future usage of pesticides. Provide documentation of ability to physically block penetration of residual pesticides in the ground into the structure. Provide documentation of ability to physically block penetration of radioactive radon gas into the structure. Provide documentation of ability to physically block penetration of methane gas into the structure.
5.LEED, ID Credit 1:
1.1 Provide documentation of long term testing supporting the environmental and health benefits obtained through the physical blocking of insects and other pests from entry to the structure, therefore reducing the need for application of pesticides over the life of the structure.
1.2 Provide documentation of testing supporting the environmental and health benefits obtained through the physical blocking of radioactive radon gas from entry to the structure from the ground underneath.
1.3 Provide documentation of ability of the Underslab vapor barrier maintain its integrity during and after concrete construction by very high puncture resistance, strength, and self-healing properties
1.05QUALITY ASSURANCE
- Manufacturer Qualifications: Underslab Barrier System must be manufactured by a company with a minimum of 10 years of experience in the production and sales of membrane waterproofing materials, as well as technical and sales personnel with backgrounds in entomology and/or pest control.
- Applicator Qualifications: A firm having at least 5 years of experience in applying these types of specified materials and specifically accepted in writing by the barrier system manufacturer.
- Materials: For each type of material required to complete the work of this section, provide primary materials which are the products of a single manufacturer.
- Pre-Application Conference: A pre-application conference shall be held to establish procedures and to review conditions, installation procedures and coordination with other related work. Meeting agenda shall include review of special details and flashing.
- Manufacturer’s Representative: Arrange to have trained representative of the manufacturer on site periodically to review installation procedures. Representative(s) must be trained in pest control as well as waterproofing.
1.06DELIVERY, STORAGE, AND HANDLING
- Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name and manufacturer.
B.Store materials in a clean, dry area in accordance with manufacturer's instructions.
C.Store adhesives and Underslab barrierat temperatures of 40oF (5oC) and above to facilitate handling
D.Store barrier cartons on pallets.
E.Do not store at temperatures above 90oF (32oC) for extended periods.
F.Keep away from sparks and flames.
G.Completely cover when stored outside. Protect from rain.
H.Protect materials during handling and application to prevent damage or contamination.
I.Avoid use of products which contain tars, solvents, pitches, polysulfide polymers, or PVC materials that may come into contact with waterproofing barrier system.
1.07PROJECT CONDITIONS
- Work should be performed only when existing and forecasted weather conditions are within the limits established by the barrier manufacturer. Barrier should only be installed when temperature is 40°F (4.44°C) and rising. Consult manufacturer for information concerning cooler temperatures.
- Proceed with installation only when substrate construction and preparation work is complete. Ensure that subsoil is approved by architect or geotechnical firm.
- Warn personnel against breathing of vapors and contact with skin and eyes; wear appropriate protective clothing and respiratory equipment.
- Keep flammable products away from spark or flame. Post “No Smoking” signs. Do not allow spark producing equipment to be used during application and until all vapors have dissipated.
- Maintain work area in a neat and workmanlike condition. Remove empty cartons and rubbish from the site daily.
1.08WARRANTY
- Provide a written 5year material warranty from the manufacturer upon completion and acceptance of the installation.
PART 2 PRODUCTS
2.01MANUFACTURER
A.Polyguard Products Inc. P.O. Box 755 Ennis, TX 75120-0755; Phone: 214-515-5000
Fax: 972-875-9425 Email:
2.02SYSTEM MATERIALS
A.High Strength Insect Barrier and Waterproofing: Shall be Polyguard TERM® Underslab Waterproofing and Insect Barrier, a 95-mil rubberized asphalt membrane consisting of a strong sheet membrane with a double thickness high strength cross-laminated polyethylene backing topped with a 65-mil thick layer of proprietary barrier sealant integrated into ahighstrength nonwoven geotextile fabric.On the fabric side, a 4" wide lap of waterproofing adhesivesealant barrieris left exposed along one edge with a removable silicone coated plastic release sheet, which creates a 4"wide self-adhesive overlap seam.
PHYSICAL PROPERTIES OF UNDERSLAB BARRIER
PROPERTY / TYPICAL VALUE / TEST METHODLong Term Resistance to Termite and Insect Penetration (Coptotermes formosanus and Reticulitermes flavipes) / 100% effective / ICC – ACC 380
Acceptance Criteria for Termite Barrier Systems
4 field sites
5 years duration
2 major species vs. controls
Tensile Strength of 1” width
Polypropylene Geotextile layer / 80.0 lb./ 36.3 kg / ASTM D 4632
Resistance to Penetration by Pesticides / 0.0% / ASTM F-2130
Resistance to Permeance by Methane Gas / 2.66 x 10 -7 / ASTM D1434
Resistance to Diffusion by Radioactive Radon Gas / 5.08 x 10 -8 / Radon Reduction Technology Laboratory Method
Resistance to Fungi in Soil 16 Weeks / No effect / GSA-PBS 07115
Lap peel adhesion / 8.7 lb./
983 N/mm / ASTM D 1876 (modified die C) lb./in width
Puncture Resistance minimum / 224lb/
996N / ASTM E 154 using 1" (24mm) Rod
In Plane Hydraulic Transmissivity of a Geosynthetic by Radial Flow / No water flow / ASTM D 6574
Peel adhesion to concrete / 20lb. /.
/2275 N/mm / ASTM D 903 lb./in width (N/mm)
Membrane Thickness / .095 inches/2.41cm / ASTM D-1000
Elongation, rubberized asphalt sealant/adhesive component / 839% / ASTM D-412
Water absorption, maximum / 0.1% / ASTM D 570
Cycling Over Crack @ -10 100 cycles / No effect / ASTM C-836 Tested @ -15°F
Low temperature flexibility / No effect / ASTM D 1970 180° bend over 1” mandrel at -20°F (-29°C).
Hydraulic Transmissivity of a Geosynthetic Using a Constant Head / No measurable flow / ASTM D 4716
Self Sealability - Water Vapor Transmission, maximum / .01 / ASTM E-96 – B US perms (ng/ (Pa x s x m2)
Resistance to hydrostatic head, minimum / 231 ft./ 70 m / ASTM D 5385
Breaking Strength of 1” width sample Polyethylene backing layer / 5470 PSI /
37.72 N/mm2 / ASTM D 882 PSI
2.03SYSTEM ACCESSORIES
A.Surface Roller Grade Adhesive or Sealant:
- Polyguard® 650 LT Liquid Adhesive: A rubber based adhesive in solvent solution which is specifically formulated to provide excellent adhesion with Polyguard Membranes to prepare TERM Underseal Barrier endlaps and areas around penetrations.
- Polyguard® California Sealant: A rubber based sealant in solvent solution which is
specifically formulated to provide excellent adhesion with TERM Barrier Membrane. The VOC (Volatile Organic Compound) content meets the South Coast Air Quality Management District regulations established under the February 1, 1991 version of Rule 1168 ©) (2) Adhesion and Sealant Applications. Polyguard California Sealant is classified as an Architectural Sealant Primer Porous; with VOC of 521 g/L. Current SCAQMD regulations for this type sealant primer are 775 g/L.
B.Repairs and End Laps
1. Polyguard® Underseal Fabric Tape: used for repairs and end laps.
C. Detailing at Penetrations - WATERPROOFING
- Polyguard FastPitch™ Penetration Sealant Collar
- Polyguard LM 85 Semi Self Leveling Sealant.
D.Corner Boots
- Polyguard® US Inside Corner Boot: 60-mil combination of rubberized asphalt bonded to polyethylene. The adhesive surface is covered with a release liner which will be removed prior to application on an inside corner to reinforce and seal corners of the Underslab Membrane.
- Polyguard® US Outside Corner Boot: 60-mil combination of rubberized asphalt bonded to polyethylene. The adhesive surface is covered with a release liner which will be removed prior to application on an outside corner to reinforce and seal corners of the Underslab Membrane.
- Polyguard® US Pit Top Corner Boot: 60-mil combination of rubberized asphalt bonded to polyethylene. The adhesive surface is covered with a release liner which will be removed prior to application on all corners to reinforce and seal corners of the Underslab Membrane
E.Detailing at Penetrations – TERMITE BARRIER
- Polyguard® TERM®SealantBarrier: Caulkable sealant barrier used around pipe penetrations.
F. Terminations onto Vertical
- Polyguard TERM 606 Double Sided Detailing Barrier
G.Drainage and Protection Board
- Polyguard® Polyflow 18: Polyflow® 18 Horizontal Drainage Mat is two-part prefabricated geocomposite drain consisting of a formed polystyrene core covered on one side with woven mono-filament filter fabric. The fabric allows water to pass into the drain core while restricting the movement of soil particles which might clog the core. The core allows the water to flow to designated drainage exits. Polyflow 18 is designed for horizontal applications.
- Polyguard® Totalflow™: Totalflow is a combination of our Polyguard sheet drain products with our unique Totalflow™ product. In the Totalflow™ system, the sheet drain performs its normal function of water collection, while the Totalflow™ section provides both water collection and a high-profile section allowing for high-capacity water flow to designated drainage exits.
PART 3EXECUTION
3.01EXAMINATION
A.Examine surfaces to receive membrane. Notify General Contractor if surfaces are notacceptable. Do not begin surface preparation or application until unacceptable conditions have been corrected.
3.02SURFACE PREPARATION
A.Protect adjacent surfaces not designated to receive waterproofing and insect barrier.
B. Prepare surfaces to receive waterproofing and insect barrier in accordance with manufacturer's instructions.
C.Concrete surfaces must be clean, smooth, and dry. Surface of base must be free of standing water.
3.03APPLICATION
A.Horizontal Application shall be in accordance with manufacturer’s instructions.
- Unroll barrier membrane with longest dimension parallel with direction of pour.
- Place high strength polyethylene backing to the soil underneath and fabric on top.
- Apply required preformed inside and outside corner boots prior to application of membrane following manufacturer’s details and specifications
- Lap waterproofing barrier membrane over footings and seal to foundation walls.
- Overlap side seams using the maximum 4" edge trim seal. If polyethylene backing has become dirty, clean its surface with 30% Isopropyl Alcohol prior to application on the 4" edge seal.
- End laps should be overlapped a minimum of 4" and addressed by applying a heavy coat of liquid adhesive sealant approximately 50-75 sq. ft. per gallon to fabric side of barrier membrane and placing adjacent sheet on top.
- After application of end lap use liquid adhesive or sealant to prepare seam and apply a 12" piece of TERM Underslab FabricTape centered over seam to seal extend out 6” past side laps.
- Roll side seams and end laps with a minimum 75 lb. steel roller with determined pressure to assure full adhesion.
- For penetrations – waterproofing:
a.Apply a heavy coat of liquid adhesive (50-75 ft2/gal a minimum of 4” out from penetrations.
b.Install Polyguard FastPitch™ around penetrations, with a minimum of 4” between all penetrations and the collar.
c.Push up any sleeves on penetrations from the portion of the penetration where the pourable LM85 sealant and TERM Penetration Barrier Sealant will be applied (minimum of 3” up)
d.Penetrations should have a clean surface (wire brush or sand) before pourable sealant is applied.
e.Apply LM 85 Semi Self Leveling Sealant at all penetrations extending a minimum of 4” onto Underslab barrier membrane, and 2” in depth, completely filling the FastPitch collar.
f.Allow LM 85 to cure until solid (30 minutes to 2 hours depending on conditions.
- For penetrations – TERM Sealant Barrier:
a. Apply minimum ½” width bead of TERM Sealant Barrier around the neck of each penetration.
- Steel reinforcements will be applied directly over the barrier membrane. It is important that reinforcement (rebar) chairs used are compatible with the system. Blocks, pavers or dobies made of concrete or brick are clearly the best choice. Individual chairs are acceptable as long as they have a flat base or bolsters with rails. Contact Polyguard Technical Service for approval and written permission for other types of rebar chairs.
- Precaution should be taken to protect the barrier membrane during placement of reinforcing or concrete.
- Prior to concrete pour:
- Visually inspect barrier membrane prior to pouring of concrete for any punctures or damage to membrane which needs to be repaired. Patch any damaged areas by applying a heavy coat of liquid adhesive at a rate of 50-75 sq. ft. per gallon to fabric side of waterproofing barrier membrane and apply a patch of fabric tape.
- Prior to slab pour all standing water must be removed from the membrane
- It is highly recommended to perform a smoke test under the TERM Underslab Barrier just before the concrete pour.
- When pouring concrete, the structural slab must be sound to avoid buckling. It is recommended that concrete be poured within 30 days of the membrane installation. Following proper ACI guidelines, concrete must be placed carefully and consolidated properly to avoid damage to the membrane. Never use a sharp object to consolidate the concrete.
.
END OF SECTION
X:/Lit/31/Guide Spec TERM Underslab Barrier R6-27-17
Polyguard Products 6-27-2017090326-1UnderslabWaterproofing with Insect Barrier