INVESTIGATION OF PHYSICO-MECHANICAL PROPERTIES AND LOCAL DISTRIBUTION OF METAL MICROSTRUCTURES

USING SCANNING ACOUSTIC MICROSCOPY

Professor Roman Gr. Maev

University of Windsor

Centre for Imaging Research and Advanced Material Characterization,
Windsor, N9B 3P4, Ontario, Canada

Abstract

This presentation deals with the analysis of the potential of a fundamentally new method – Scanning Acoustic Microscopy – for studying the physical microstructure and the dynamic processes of failure in advanced materials of the most diverse nature, including metals and various metal alloys, matrix metals, multi-layer systems etc. Work in the ultrasonic microvision technology has given rise to a new experimental means for generating images of the interior of matter with a resolution comparable to that of light micrographs, with many practical applications.

Introduction

There are at present several effective methods for the investigation of physico-mechanical properties and local distribution of microstructures in various advanced materials. Most important among these are electron and optical microscopy, a number of spectral techniques, including traditional ultrasonic nondestructive materials characterization and evaluation (NDE) methods. The role of NDE is changing and will continue to change dramatically. It has become increasingly evident that it is both practical and cost effective to expand the role of NDE and quality control to include all aspects of production process and to introduce it as much as earlier in the manufacturing cycle. Today, and even increasingly in the future, using advanced optical, thermal, ultrasonic, laser-ultrasound, acoustic emission sensors, vibrational, electro-magnetic, X-ray technique, etc., as well as modern measurement technique, along with signal/data processing, on-line information on the processing conditions can be continuously generated. Real-time process monitoring for more effective and efficient real-time control of various processes and as a result improved vehicle manufacturing quality control inspection and reliability will now become a practical reality.

The new materials structures, joints, parts, components made from various materials demand the innovative applications of modern NDE techniques to monitor and control as many stages of the production process as possible. Simply put, intelligent advance manufacturing is impossible without integrating modern nondestructive evaluation into the production system.

Works in the imaging systems, including optical, infrared, microwave, ultrasonic, etc. technique, has given rise to a new experimental means for generating images of the interior of matter with many practical applications.

Background

Acoustical imaging is well-known as a powerful tool for studying the microstructure and properties of materials, and it has attracted the efforts of research groups in different countries. Actually, high-resolution acoustic imaging, or acoustic microscopy is a relatively new technique. The idea of a microscope using sound rather than light was first put forward by a Russian scientist (Sokolov, 1934). However, due to the limitations of existing technology, it was many years before high-resolution acoustic imaging was actually realized. The first prototype acoustic microscope was built in the USA, (C. Quate, Stanford University) in 1974. The industrial application of acoustic microscopy is still a developing field of study.

The activity of most groups in the world is focused on the development and application of acoustic microscopy to surface and nearest subsurface layers of specimens. For example, the group of Prof. A. Briggs (Oxford, UK) [1] has proposed effective methods of characterizing surface and subsurface cracks, plastic deformations and other surface and subsurface defects in materials. Prof. B. Khuri-Yakub (Stanford, USA) [1,2] and his group are successfully developing quantitative methods for characterization of elastic properties at the surfaces of solids. Prof. J. Kushibiki (Tohoku Univ., Japan) [1] is developing the line-focus-beam method to study surface elastic anisotropy; and Prof. G. Wade (Santa-Barbara, USA) [1,2] has worked on signal and image processing from surfaces and subsurface regions. Centre for Imaging Research and Advanced Materials Characterization (Windsor, Canada) have developed expertise in the visualization of structures deep inside objects. The results of our research on transmission acoustic microscopy is well appreciated for the study and NDE of films and thin specimens New methods was developed for visualizing bulk microstructures of anisotropic materials and have successfully applied it to investigations of defect microstructure of advanced crystalline materials, including carbon materials, high-Tc superconducting crystals, various metals, including austenite steel, aluminum alloys and others [2].

Our group also has developed various short-pulse acoustic microscopes for bulk microstructure characterization of materials and currently develop next generation of 3D imaging scanning acoustic microscope [3}. In the Centre have designed and built a few different prototypes of hand-handle acoustic imaging systems with 2D multi-lens and 2D matrix array transducers. Based on that knowledge and research experience, we have studied the microstructure and properties of various advanced materials as well as have undertaken examination of various welding NDE of casting aluminum alloys, riveting and resistance spot-weld quality control inspections for the automotive industry, among others.

Acoustic Imaging Methods

The scanning acoustic imaging technique uses ultrasonic pulse for near-surface and bulk structure examination. A single narrow pulse generated by the transducer travels towards the sample surface where it is partially reflected back while the reminder propagates through the specimen interacting with internal structure. The reflected signal, which is received by the transducer generally, contains a peak corresponding to the surface reflection succeeded by echoes reflected from the internal structure These echoes reach a transducer after a time delay that depends on the ultrasound velocity in a particular area of the sample. The amplitudes of the reflected and transmitted waves are a function of the acoustic properties of the material at each scanning point. Echo reflection can be caused by different kinds of non-homogeneity or discontinuity (for example: phase and grain boundaries, voids, inclusions and cracks) [3–9].

In our research we use two kinds of desktop acoustic microscopes and a hand-held array transducer. The first one is ELSAM (Ernst Leitz Scanning Acoustic Microscope) manufactured by LEITZ Ltd. The second ultrasonic system is an ultra-short pulse reflection ultrasonic microscope (SPSAM) designed by the Acoustic Microscopy Center of the Russian Academy of Sciences (Moscow, Russia).

ELSAM

LEITZ has developed the ELSAM, with a frequency range from 0.1 to 2.0GHz, six magnification selections with a maximum resolution of 0.3µm [4]. It can operate both as an optical reflection microscope and as an acoustic microscope. The scanning of the acoustic objective is accomplished with the oscillator coil drive. The microscope produces 512  512 pixel images with a scan area starting from 0.8  0.8 mm down to 40  40 µm.

Its acoustic focusing system uses a plano-concave sapphire (Al2O3) lens with a zinc oxide piezo-electric transducer and a wide aperture. So-called continuous mode is used, that is the excitation electric signal is produced by a high frequency generator and it consists of several periods [10].

The ELSAM acoustic microscope was designed mainly for a high-resolution surface and subsurface investigation and it does not allow for deep structure imaging.

Fig. 1. ELSAM acoustic microscope / Fig. 2. Desktop SPSAM acoustic microscope

SPSAM

This wide-field, short pulse SAM operates with a frequency range between 25–100 MHz and various lens apertures [3, 5]. The frequency and design of each of the lenses was based upon the analytical and numerical calculations of the propagation of focused ultrasonic pulses through aluminum casting samples. Short probe pulses (3–5 oscillation periods) allow for the resolving of fine microstructural details at a depth of 5 mm, with a resolution of 50–150 µm.

The short probe pulses are partially reflected back to the microscope whenever a non-homogenous object is encountered. The received reflected signal is stored in a personal computer where special software can recognize and process the reflections from different internal defects and generates visual output. This output will then be analyzed and interpreted by researchers.

A mechanical scanner is used to provide one and two-dimensional movements of the acoustic sensor for B-scan and C-scan representation of the specimen's internal structure. A scanner with a scanning area of 80  120 mm, a maximum mean scanning velocity of 2 mm/sec and a precision of 0.05 mm was used. A computer received the collected data and provided material interface detection and recognition as well as A-scan, B-scan and C-scan imaging.

The pulse method features an adjustable time-delay gate that is used to collect individual echo-signals. All of the collected signals from a scanning area of interest, at various depths of penetration, are used to represent the C and B acoustical images [2]. Therefore, the delay gate is useful to study reflected signals from a particular region. The depth of penetration of acoustic waves is inversely proportional to the density, acoustic velocity and attenuation in the material.

With respect to image processing, current methods are based on amplitude and delay time measurements of the demodulated reflected pulses. The processing of fully digitized signal waveforms permits one to increase measurement accuracy and to investigate the frequency dependence of attenuation. However, special methods of digital processing are required if the return signals are greatly overlapped or transformed. This occurs when the thickness of an inclusion is about one wavelength or it is too deep to be detected using a high frequency probe. During experimental preparations, new algorithms for digital signal processing were developed based on non-linear parameter estimation. This method permitted us to separate pulse responses reflected from each inhomogeneity and therefore measure their time delay and amplitude [1, 3, 5].

2D Matrix Transducer

Matrix and array transducers offer several enhanced capabilities in imaging and beam forming compared to a single transducer scanning system. The matrix transducer technology makes fast data acquisition and imaging possible, while using motionless transducers. Advanced technologies such as micro-machining and IC manufacturing can produce matrices of thousand elements of less than 0.1mm in size, creating an acoustic analog of CCD camera [6]. This size is essential for phased arrays, given the element size must be around half a wavelength for efficient beam-forming [7]. However, for matrices not using phased principles to build the acoustic beam, such small elements represent a disadvantage. Matrix transducers having such a high density can only operate in the pick-up mode due to power dissipation restrictions. Moreover, acoustic wavelengths at megahertz frequencies are at least 103 times larger than the light wavelengths, thus, there seems to be no reason to go down to the micron range resolution [8].

One of the array transducers used in our study has the diameter of 8.0mm and contained 52 emitting-receiving broadband elements with the central frequency around 20MHz; the matrix period was 1.0mm, individual elements being of 0.740.74mm2 square. The elements were switched one at a time using a custom coaxial relay multiplexer interfaced with the parallel port. Experimental data have been acquired with a USD-15 (ultrasonic pulser Krautkramer) connected to a TDS-520 (Tektronix digitizing oscilloscope), digital data were transferred to the PC via a GPIB interface card. The sampling rate (TDS-520) used in the experiments was 500 MSamples/s. For image smoothing and quality enhancing various 2D interpolation algorithms were used.

The imaging capability of the system generally depends on the penetration depth of the transducer. The penetration depth drops with the decreasing size of the element due to the beam divergence and the increasing electrical mismatch with 50Ohms transmitters and receivers. In general the image quality gets worse for smaller and deeper reflectors. Images obtained on 1.0 and 2.0mm flat-bottomed holes drilled inside a 319 aluminum casting sample are given in Figures 3 and 4. The holes were grouped by four for the depth range from 1.0 to 8.5mm separated by 0.5 mm depth step within a group. Featured C-scans were obtained to 8.5mm deep for 2.0mm flat-bottom holes, however reflectors of 1.0mm diameter were only clearly observed to 4.5mm deep.

Fig. 3.C-scans of 1mm flat-bottom reflectors located in the depth range: a) 1.0–2.5mm; b) 3.0–4.5mm (0.5mm step). / Fig. 4.C-scans of 2mm flat-bottom reflectors located in the depth range:
a)1.0–2.5mm; b) 7.0–8.5mm (0.5mm step).

In Figure 5 example of an imaging application for the matrix transducer portable device is given. The generated acoustic images represent laser spot weld samples of 0.75 and 1.0mm thick. Surface burn marks were respectively around 3.0 and 7.0mm.

Fig. 5. Acoustic images of laser spot welds generated with a desktop scanning acoustic microscope and corresponding images obtained with the 52-element array: (a), (b) 0.75mm thick steel plate approximately 3.0mm. weld; (c), (d) 1.0mm thick steel plate around 7.0mm weld.

Fig. 6. Acoustic images of copper wires inside the flexible printed circuit board, which is incorporated into 1.5mm thick plastic cover.

Matrix transducer is capable to visualize location and orientation of the flexible printed circuit board (PCB) inside the plastic. In Figure 6, images of 0.2mm thick and 2mm wide wires are shown. The separation between the wires in the right image is 1mm.

High-Resolution Ultrasonic Inspection Methods for Joint Inspection

The traditional methods of any joints monitoring are combinations of visual inspection, pry testing and destructive tests, like in the resistance spot welds, with hammer and chisel. The only effective non-destructive method has been the ultrasonic pulsed echo technique based on an evaluation of ultrasonic echo patterns in a specimen. The current ultrasound technique is capable of determining the approximate parameters of the joint. Disadvantages of that technique and method are evident: a wide range of ambiguity in treating echograms; a high sensitivity of the result to the alignment of the transducer perpendicular to the surface; the dependence of the results on operator experience and skill; the impossibility of building the method into an on-line process; etc.

The hottest NDT problem today is high-resolution inspection of welding joints. The problem of inspection for many-layered (2 or more layers) joints formed by spot-welding or diffusion welding is under investigation. Using acoustic imaging systems with short probe pulses provides a way to visualize small-scale failures of contact and other defects at different depths. For spot welding acoustic imaging systems makes it possible to inspect fine details of internal areas of joints in spite of the curved outer surfaces of welding spots.

To show the potential of high-resolution acoustic imaging technique we used a wide-field short-pulse acoustic microscope (see Fig. 2). The method was applied to evaluation of spot-welding joints of two steels sheets 1-2 mm thick of each. In spite of the fact that the top surface of specimen was distributed by welding, high quality acoustic images of the nugget zone were obtained [9]. The C-scan and B-scan images contain well-shaped defects of joints and the confirm power of the method for NDE and QC of spot-welded joints. The combination of the C-scan and the B-scan images in one picture can give a real 3D image of the defect distribution inside the welding zone, which can be also very useful from a technological point of view.

The current results of this study show that high-resolution acoustic imaging technique can be successfully applied in spot welding as an effective inspection method to detect any kind of defects, and can be used for manufacturing welding quality control.

Fig. 7. C-scan Images of the interface area (depth penetration 1 mm) from the spot welding samples (Ultrasound frequency 50 MHz).

Acoustic imaging methods based on acoustic visualization and characterization are extremely promising also for laser welds and rivet joints quality evaluation (see figure 5). This technique can provide total bulk reconstruction of the joint zone, including the topography of the top and bottom faces, the structure of the interface between the sheets, and any expulsions, voids, pores, cracks or other defects in the welding zone.

Bulk and Subsurface Structure Analysis of Aluminum Casting Using Acoustic Imaging Methods

The metallurgical structure of aluminum castings (grain structure, inclusions, porosity etc.) is usually inspected with optical and scanning electron microscopy. [10, 11]. These both methods provide information only from the surface of a sample while requiring as-polished or etched metallographic specimens [12]. In a bulk structure study, as a rule, a series of cross sections is required [112]. Through the image processing some important quantitative characteristics of the casting structure may be provided [14].

The main point of this study was to apply the method of acoustic microscopy for the subsurface and non-destructive bulk structure visualization as well as casting quantitative characterization.

The service properties of Al-Si-Cu castings depends on their chemical composition, liquid metal treatment and solidification rate. In general, a small, equiaxed grain structure, fine constituents and absence of structural discontinuities produces optimal properties. Consequently, the casting responds better to heat treatment processes. Porosity in aluminum casting can result from excessive amounts of hydrogen (gas porosity) or a lack of feeding (shrinkage porosity) [15, 16]. Gas porosity takes the form of rounded cavities while shrinkage porosity appears as elongated interdendritic cavities. Commercial castings can contain either type or both in combination. The service performance of automotive components, especially during high cycle fatigue, depends on the morphological characteristics of the porosity. These characteristics can be determined using traditional destructive microscopy techniques, however these techniques are costly and time consuming. They do not allow process engineers to make proactive interventions. Consequently, it is essential that quick, non-destructive techniques for the evaluation of internal casting structure be developed that can be utilized in an industrial environment.