EDP Reference Number: EDP-TCR318-0
Supporting Information for Structural Engineering Drawings
1. Digital Signatures
1.1 The EDP consists of two sets of files, one set with each file digitally signed, and the second set not digitally signed files.
1.2 Hongkong Post e-cert is used to provide the digital signatures.For all files in each file type described in the next section, there should be a corresponding e-certified file that adopts the prefix of the unsigned file but ended with a file extension .p7s.
1.3 Each EDP will be dispatched with a notification of Appointment of Authorized Representative signed by the Architect / Engineer Designate listing the name and post of the officer who is authorized to sign the EDP with Digital Signature.
2. Notes for Viewing, Editing and Printing the Files
2.1 The format of document files and supporting files are as follows:
Filename Extension / Format of File.doc, .rtf / Microsoft Word 97 or later version
.dwg / AutoCAD 2000 or later version
.pdf, .tiff / Adobe Acrobat Reader 4.0 or later, TIFF
2.2 Document files are provided in two forms:-
· Editable Files denoted with prefix ‘E’ are files containing the content of Tender Document in the editable format.
· Image Files denoted with prefix ‘I’ are files containing the printed image of the Editable Files.
3. Content Description
Only file name of editable files are shown in the following list of contents.
3.1 SEB TYPICAL DETAILS
File Name
/Description
/Revision History
(if any)E-sd001.dwg / DRAWING LIST OF SEB TYPICAL DETAILS / A
E-sd002.dwg / GENERAL NOTES
E-sd003.dwg / CRANKING OF BARS, HOOKS & BENDS
E-sd004.dwg / TYPICAL DETAIL OF BEAM STIRRUPS & SPACER BARS, RECTANGULAR COLUMN BINDERS / A
E-sd005.dwg / STEEL REINFORCEMENT ANCHORAGE & LAP LENGTH REQUIREMENT
E-sd006.dwg / TYPICAL WALL JUNCTION DETAILS
E-sd007.dwg / TYPICAL DETAIL OF R. C. PARTITION WALL & WALL BASE
E-sd008.dwg / TYPICAL DETAIL OF R. C. STRUCTURAL WALL
E-sd009.dwg / TYPICAL DETAIL OF TRIMMING BARS FOR WALL OPENING
E-sd010.dwg / TYPICAL DETAIL OF TRIMMING BARS FOR PERMANENT SLAB OPENING
E-sd011.dwg / TYPICAL DETAIL OF TRIMMING BARS FOR TEMPORARY SLAB OPENING
E-sd012.dwg / TYPICAL DETAIL FOR PIPE DUCT OPENING IN SLAB
E-sd013.dwg / REQUIREMENT OF SPACER BLOCK, ‘U’ BARS & STEEL CHAIRS FOR STRUCTURAL ELEMENT
E-sd014.dwg / CURTAILMENT OF LONGITUDINAL BARS IN BEAMS
E-sd015.dwg / TYPICAL DETAIL OF BEAM AND BEAM ‘L’ JUNCTION
E-sd016.dwg / TYPICAL DETAIL OF COLUMNS / A
E-sd017.dwg / TYPICAL DETAIL OF COLUMN & BEAM JUNCTION / A
E-sd018.dwg / TYPICAL DETAIL OF 100 THICK GROUND SLAB ON GRADE
E-sd019.dwg / TYPICAL DETAIL OF 150 THICK GROUND SLAB ON GRADE
E-sd020.dwg / TYPICAL DETAIL OF 200 THICK GROUND SLAB ON GRADE
E-sd021.dwg / TYPICAL DETAIL OF EXTERNAL DRIVEWAY & CARPARK GROUND SLAB ON GRADE (1 OF 5)
E-sd022.dwg / TYPICAL DETAIL OF EXTERNAL DRIVEWAY & CARPARK GROUND SLAB ON GRADE (2 OF 5)
E-sd023.dwg / TYPICAL DETAIL OF EXTERNAL DRIVEWAY & CARPARK GROUND SLAB ON GRADE (3 OF 5)
E-sd024.dwg / TYPICAL DETAIL OF EXTERNAL DRIVEWAY & CARPARK GROUND SLAB ON GRADE (4 OF 5)
E-sd025.dwg / TYPICAL DETAIL OF EXTERNAL DRIVEWAY & CARPARK GROUND SLAB ON GRADE (5 OF 5)
E-hoard-5sk1.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk2.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk3.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk4.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk5.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk6.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk7.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk8.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk9.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoard-5sk10.dwg / 1.5m & 2.0m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 5)
E-hoi-sk1.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk2.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk3.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk4.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk5.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk6.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk7.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk8.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk9.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
E-hoi-sk10.dwg / 1.1m WIDE HOARDING AND COVERED WALKWAY FOR BUILDING HEIGHT EXCEED 30m (TYPE 6)
3.2 STRUCTURAL ENGINEERING DRAWINGS
File Name
/Description
/Revision History
(if any)3.3 For each native file, image file and referenced file, there is a corresponding digitally signed file with the file extension .p7s.
4. Appendix
Appendix A - Filename Convention for Drawing Files
Every CAD drawing should be given a unique file name. It is usually different from the actual drawing number because DOS allows only a maximum of eight characters for a file name. The file name extension of AutoCAD drawing by default is [.dwg]. A standard naming convention of drawing files for SEB is used to enable the users to recognize the type and nature of a drawing file easily. Users are required to follow the rules given in the following paragraphs.
Syntax of a drawing File Name:
Filename = CnnTTmmR.dwg
Legends :
C is a code of 1 character long which indicates the type of the drawing which is a Framing plan, Details, or Steelwork. It should be one of the following character codes:
Drawing type / CFraming / F
Detailing / D
Structural Steelwork / S
nn is a code of 2 characters long which stands for the floor number/member mark. If there are more than one floor number/member mark in the same drawing, the smallest number should be used.
Floor number / Member mark / nnNo floor number/member mark / 00
1 to 99 / 01 to 99
Basement 1 to 9 / B1 to B9
Basement / BA
Ground / GD
Lower Ground / LG
Lower Roof / LR
Mezzanine / MZ
Roof / RF
Upper Ground / UG
Upper Roof / UR
TT is a code of 2 characters long which indicates the type of elements being drawn. It can be as follows :
Beam / BE
Column / CL
Drawing List / DL
Foundation / FN
Floor Plan / FP
Ground Investigation / GI
Layout Plan / LP
Loading Schedule / LS
Miscellaneous / MI
Retaining wall / RW
Staircase / SC
Section / SE
Site Formation / SF
Slab / SL
Septic Tank / ST
Tank / TK
Steel Truss / TR
Wall / WA
Water Tank / WT
mm is a code of 2 characters long which stands for the sheet number with the same CnnTT. Code 01 must be used for the first drawing.
R is used to indicate the revision number for drawing.
Examples:
Drawing /Filename
THIRD FLOOR FRAMING PLAN / F03FP01R.C. DETAILS OF 15 FLOOR BEAMS (SHEET 4 OF 5 ) / D15BE04
R.C. DETAILS OF SECOND FLOOR SLABS (2 ) / D02SL02
FRAMING OF STAIRCASE NO. 7 TO 9 / F07SC01
GROUND INVESTIGATION PLAN / F00GI01
COLUMN SCHEDULE ( 3 ) / D00CL03
R.C. DETAILS OF WALL 3 / D03WA01
STRUCTURAL DETAILS OF STEEL STAIRCASE NO 1 / S01SC01
Appendix B - Settings of AutoCAD
1). Text style are:
Text Style / Text Height( output size ) / Usage
ROMANS / 2 mm or
3 mm / General notes, texts in table form, dimensions, marks
ROMAND / 5 mm / Titles and section marks
2). Plotting size of the colour number are :
Colour Number / Pen Width ( mm )7, 83, 103, 123, 143, 181 / 0.125
41, 43, 44, 64, 81, 101, 121, 124, 142, 161, 241 / 0.187
80, 120, 140, 203, 240, 253 / 0.250
122, 160, 241, 243 / 0.312
42, 84, 104, 221 / 0.375
60, 61, 63, 102 / 0.500