CUBICLECURTAINSPECIFICATIONS

PART1-GENERAL

1.1DESCRIPTION

A.Provide cubiclecurtainsand trackinaccordance withprojectdocumentsandplans.

B.Relatedspecificationsections:

1.Division6Section–RoughCarpentry

2.Division9Section–GypsumBoardAssemblies

3.Division9Section–AcousticalPanelCeilings

1.2QUALITYASSURANCE

A.Providecubiclecurtains,track,andhardwarefroma firmthathasspecializedin thefabricationandinstallationof suchworkfor atleastfive(5)yearsinprojectsof similarsizeand scope.

B.Providecubiclecurtains,track,andhardwareascompleteunitsproducedbyasinglemanufacturer,includingthenecessary mountingbrackets,hardware,fittings,fastenings,andinstallation.

C.Installation shallbeperformedbyan authorizedmanufacturer’srepresentativeexperiencedinthe installationandmaintenance of suchassemblies.

1.3STANDARDS

A.Exceptasmodifiedbygoverning codes andcontractdocuments,complywithapplicableprovisionsandrecommendationsofthefollowing:

B.Fabrics areabletowithstand a temperature of not more than160 degreesF.

C.Provide curtainsthatconformtoNFPA701 Fire TestsforFlameandResistantTextilesandFilms,andCaliforniaTitle 19regulations.

1.Identifyfabricswithappropriate markingsof applicabletestingandinspectingagency.

1.4SUBMITTALS

A.Manufacturer’s Data: Includedurability,laundrytemperaturelimit,faderesistance,andfire-testresponse characteristicsforeachtype of curtainfabricindicated.

B.Shop drawings:Submitdrawingsshowinglayoutandcubicleconfigurations,sizesofcurtains,number ofcarriers,anchoragedetails,andconditionsrequiringaccessories.Indicatedimensionstakenfrom fieldmeasurements.Includedetailson blockingaboveceilingandinwalls.

C.VerificationSamples: SubmitFull-sizeunitsof eachtypeofthefollowingproducts:

1.CubicleCurtains: Submit12 inchsquareswatch(memo)samplesillustratingfabriccolor,patternrepeat,andweaveforeach fabricspecified.

2.CurtainTrack:Submitsampleassembly notlessthan4incheslongincluded afull-sizecarrier,endcap,andpullout.

D.MaintenanceInstructions:Submitmanufacturer’sprintedinstructionsforcleaningandmaintenance of the products.

1.5PRODUCTDELIVERY,STORAGE,ANDHANDLING

A.Subcontractorshallnotinstallcubicle tracksorcurtainsuntilspacesare enclosedandweatherproof,wetworkinspacesiscompleteanddry,workaboveceilingiscomplete,andambienttemperatureandhumidity conditions aremaintained atthelevelsindicatedforprojectwhenoccupiedforitsintendeduse.

B.Inspectmaterials atdeliverytoassurethatspecifiedproductshavebeenreceivedand arefree of damage.

C.Fieldmeasurements:Verify dimensionsby fieldmeasurementsbefore fabrication.SchedulewithconstructionprogresstoavoiddelayingtheWork.

1.6WARRANTY

A.Provide awrittenwarranty agreeingtorepairorreplacefabriccurtains,hardware ormaterialsdue to faulty workmanshipor installationfor a period ofone(1)year.

PART2–PRODUCTS

2.1MANUFACTURER

A.Provide cubiclecurtainsystem as producedby one manufacturer.

B.Approvedmanufacturers,Basis ofDesign:CubeCareCompany

6043 NW167thStreet,SuiteA-23

MiamiLakesFlorida33015

P: 305-556-8700

F:305.556.8787

C.Substitutionsarenotpermitted.ProvideCubicleCurtainsfromCube CareCo.inaccordancewith specifications,drawings,andcontractdocuments.

2.2MATERIALS

A.CubicleCurtainFabric:Providecubiclecurtainsfabricatedwiththe specifiedmaterials.Nosubstitutionspermitted.

Manufacturer/Mill:Pattern:

Color:

FabricWidth:Repeat:

Railroaded/Non-Railroaded:

B.Mesh (optional):

1.Mesh isnotrequiredwhenusingCubeCare ClassicSuspendedTrackorifSprinkler Systemisnotpresent,perNFPA13.

2.Mesh Specifications: InherentlyFlame ResistantPolyesterMesh

a.100%polyestermeshwith½inchdiameteropenings

b.IntegratedHeaderandFooter

c.StandardWidth: 20”

d.Color: White or Buff

2.3FABRICATION

Fabricatecurtainstocomplywiththefollowingrequirements:

A.Fabricto betabledandsquared.

B.Width:Equalto tracklengthfromwhichcurtainishungplus 10 percentaddedfullness,butnotlessthan12 inchesof addedfullness.

C.Length:Equaltofloor-to-ceilingheightminus2inchesfrom finishedceiling attop,andminusdistanceabove the finishedfloor atbottomasfollows:

1.CubicleCurtains: 12inches

2.ShowerCurtains: 2inches

D.Construction:Doublelockstitchedtotopofcurtainfabric,with a1-1/4inchwide triplethicktopseam.

E.Grommets: Providenickel-plated ½inchrust-proofgrommetsinsertedinthe tophem ofmesh at 6inchesoncenter.

F.HemConstruction:

1.Mesh Header: Tobe 1-1/2” wide,doublethickanddoublelockstitched.

2.Top FabricHem/MeshFooter: double thickanddoublelockstitchedto meshwith a5/8inchwideseam.

3.BottomHem:Tobe 1-1/4incheswide double thickanddoublelockstitched.

4.SideHems: To be 1-1/4inchwidedoublethickanddoublestitched.

5.All hemsandseamsto besewnwith100% mercerized,polyestercore thread.Nylon threadisnotacceptable.

6.Allseamstobe flatwithno puckering.

G.VerticalSeams(fornon-railroadedfabricsorpanelconstructiononly):Notlessthan ½inchwide,doublethickanddoublestitched.

H.FabricRailroading: Fabricsaretobe railroaded whenpossibletoprovideaseamlesscubiclecurtain.Allotherpatternsaretobe patternmatchedand sewnwithverticalseams.

I.“FramedCurtains”(optional): Provide curtainswheretop andsidesofmesh are outlinedwithfabricthatmatchesthebody ofthe curtain.Frameisnottohave any exposedfabricedges.

J.Curtain Snaps(optional):Attopwidthof fabric,rustproofnickel-plateddouble sidedsnapsspacednotmorethan4½”on centerandmachinedinto thetopheaderof the fabric.PlasticCap Snapstobe placed 4 ½” on centerandmachinedinto thefooterof themesh.

Both themesh footerandfabricheaderto bereinforcedwithflameresistantpolyestertwilltape.

K.Maintenancelabels:EachcurtainistohaveaCubeCareCompany labelsewninto thetopfabricseam.LabelindicatesmaterialsmeetStandardsandRegulations,indicatesthesize,numberof grommets,andmaintenancehistory.

PART3–EXECUTION

3.1EXAMINATION

A.Examinesubstrates,adjoiningconstructionandconditionsunderwhichthe workis to beinstalled.The workshallnotproceeduntilunsatisfactoryconditionshave beencorrected.

3.2INSTALLATION

A.Install allmaterialslevelandplumb,accordingtomanufacturer’swritten instructions.

3.3PROTECTION

A.Protectcurtainsfromsoiling or damageafterhanging.

ENDOF SECTION