DETENTIONS IN PORT OF KOPER IN THE YEAR 2008

1
Date & Place of Detention / 2
Vessel Name, Type, IMO No & GT / 3

Flag

/ 4
Owners
Operator

Charterers

/ 5
Classification Society / 6
Summary
15/01/2007
Koper / AP LIGHT
General cargo
7628863
3419 / Cambodia / Partner Ltd.
Rostov on Don
Russia / Posski Rejstr Statkov / Detained for 350 days.
24 recorded deficiencies.
Safe manning certificate expired. IOPP certificate expired. Chart 1471 missing. Wheelhouse bulkhead corroded through. Main magnetic compass with big air bubble. Alleyway threshold corroded through. Battery room bulkhead corroded through. Three lifebuoys in bad condition. Second eng. cabin bulkhead corroded through. Galley air vent corroded through. On davits limit switches sized. Top of tank no 2 STB cracked.
Wing tank no 2 bulkhead corroded through. Windlass oil leaking. Hatch covers hydraulic pipes leaking. Emergency fire pump engine oil leaking. DG no 1 fuel leaking alarm inoperative. Both cold room compressors inoperative. No sufficient food quantity on board. Crew does not use personal protective equipment. ME cooling water leaking. Due to improper lub oil ME with insufficient power. ISM maintenance of ship and equipment failed.
27/10/2007
Koper / SLAVUTICH- 10
General cargo
8841498
2.193 / Montenegro / Nimont Ltd.
Bar
Montenegro / Montenegro / Detained for 5 days.
35 recorded deficiencies.
In minimum safe manning certificate master missing. In IOPP certificate bilge tank recorded twice. Sludge and bilge tanks are full. Main magnetic compass missing. Spare batteries for 2 way VHF expired. Radio room bulkhead corroded through. ER skylight corroded through. PS life raft improperly lashed. Funnel corroded through. EDG room bulkhead corroded through. Self igniting lights inoperative. Boat swain cabin bulkhead corroded through. Sewage discharge connection improper. All navigational lights with improper lights. Main fire line temporary repaired. Chief engineer cabin corroded through. Front bridge bulkhead corroded through. Chief engineer cabin window glass cracked. Seaman cabin bulkhead glass cracked. STB entrance door corroded through. On standard discharge connection additional pipe fitted. Spare cabin bulkhead corroded through. FCSL deck corroded through. Eight hatch coaming frames cracked. On FCSL bell missing. In tank 2C five deck support pillars and one beam corroded through. In tank 4 PS eleven frames and 2 beams corroded through. In tank 5 STB two deck support pillars cracked and corroded through. In tank 6 STB two deck supporting pillars corroded through. On PS ME jacketed lines disconnected. On both main engines fuel leaking alarms inoperative. ER bilge full of DO. QCV on fuel tank blocked with wire. ER fire sensors inoperative. ISM maintenance of ship and equipment failed.
04/01/2008
Koper / GREEN FLOWER
General cargo
7397971
1.628 / Panama / Alemar s.r.l.
Napoli
Italy / Istmus Bureau of Shipping / Detained for 4 days.
1 recorded deficiency.
Lost of stability after loading lumber on deck.
08/01/2008
Koper / BURAKBEY
General cargo
8408428
2.683 / Malta / Genta Genel
Istanbul
Turkey / Lloyd's Register / Detained for 2 days.
13 recorded deficiencies.
Air condition room air vent corroded through. Magnetic compass with air bubbles. Artificial opening in funnel not welded but filled with silicon. Paint room air vent cover's frame corroded through. Dogs for paint room air vent cover missing. Dogs on CO2 room air vent cover missing. Boatswain store room air vent corroded through. In FCSL several electric cables not insulated. STB WB11 air pipe corroded through. Hatch covers hydraulic pipes leaking. Boiler protection fire line disconnected. Bilge under diesel generators to be dried and cleaned. ME fuel leaking alarm inoperative.
14/01/2008
Koper / CAPETAN COSTIS
Oil tanker
8806888
25.368 / Bahamas / Tomasos Brothers
Piraeus
Greece / Lloyd's Register / Detained for 2 days.
9 recorded deficiencies.
No procedure in place to inform PSC that the ship is eligible for MEI, PS standard discharge connection with improper flange, Emergency exit locked, Emergency fire pump with insufficient pressure, Fuel leaking alarm on DG1 & DG3 inoperative, ME fuel leaking alarm inoperative, Lifeboat winch brake wire torn, On STB lifeboat sprinklers inoperative. Abandon drill failed.
15/01/2008
Koper / MARAS
General cargo
7015509
1.090 / Sierra Leone / El-Amira
Ravenna
Italy / Dromon Bureau of Shipping / Detained for 8 days.
24 recorded deficiencies.
Navigational lights alarm inoperative. Spare side navigational lights with improper corrugated glasses. ER air vent cover sized and without gaskets. Cook cabin bulkhead corroded through. Front bridge bulkhead temporary repaired with block of concrete. All 4 air pipes on WB5 tanks corroded through. Hatch covers corroded through. Hatch coaming 2 inner frame corners corroded through. Air pipes on WB4 PS & STB corroded through. Air pipes on WB3 PS & STB corroded through. Hatch coaming 1 both inner corner plates corroded through. Air pipes on WB2 PS & STB corroded through. Air pipes on WB1 PS & STB corroded through. FP air pipe corroded through. PR air vent corroded through. On PS hull corroded through. Rope store hatchway corroded through. In FCSL several frames corroded through. In FCSL one beam cracked. RR air vent corroded through. STB FWD hold air vent corroded through. Steering gear emergency exit blocked. Emergency fire pump insufficient pressure. ISM maintenance of ship and equipment failed.
18/01/2008
Koper / FARWA
General cargo
7633193
2.003 / Libya / North African Maritime Transport
Tripoli
Libya / International Naval Survey Bureau / Detained for 9 days.
33 recorded deficiencies.
EIAPP certificate missing. ORB not appropriate. Chart 1471 missing. Navigational lights alarm inoperative. Side and mast navigational lights with improper glasses. Main magnetic compass inoperative. Gyro compass repeaters inoperative. Funnel corroded through. Funnel dampers inoperative. ER air vent covers obstructed with drums. On rescue boat engine safety pin missing. AB cabin window not water tight. Both aft hold air vents artificially holed. One guide head on hatch cover detached. STB chain pipe corroded through. Galley hood dirty. In galley several electrical cables not isolated. Diesel generator room dirty and slippery. DG1 & DG3 without guards. Steering gear room floor slippery. Emergency compressor inoperative. Emergency fire pump inoperative. Ship has no bilge holding tank. Illegal discharge valve fitted on OFE outboard line. Oil filtering equipment inoperative. ME fuel leaking alarm inoperative. On ME cooling water leaking. QCV inoperative. Sanitary facilities in poor condition. Maintenance of ship and equipment failed. Emergency preparedness failed.
21/01/2008
Koper / NAXOS EXPRESS
General cargo
7432836
1.633 / Panama / Alkionis Shipping Co.
Drapetsona
Greece / Hellenic Register of Shipping / Detained for 5 days.
23 recorded deficiencies.
In wheelhouse clear screen view window missing. Funnel corroded through. Wheelhouse bulkhead corroded through. STB side navigational light glass cracked. Monkey bridge deck temporary repaired with tape. Air condition cables improperly pass through the bulkhead. Chief engineer cabin bulkhead corroded through. Front bridge bulkhead corroded through. In hold PS two frame corners detached. In hold several frames bent. In hold 2 tripping plates corroded through. PS chain pipe corroded through. Emergency fire pump insufficient pressure. In paint room air vent missing. Hatch covers corroded through. In ER grey water pipes temporary repaired. ME fuel leaking alarm inoperative. Sludge pump lines connected to the OFE. Bilge and sludge pump suction pipes made of rubber. DG No 2 water cooler leaking. Fuel tank gauges improper. Ship has no holding tank. Maintenance of ship and equipment failed.
22/01/2008
Koper / GLORIA II
Bulk carrier
7725532
3.127 / St. Vincent & Grenadine / Errada Shipping
Vlore
Albania / Bureau Veritas / Detained for 3 days.
Radio room window glass cracked. Galley scuttle glass cracked. Mess room scuttle glass cracked. Deck between hold 2 and bridge corroded through. Deck between hold 2 and bridge buckled. On DG fuel tank QCV disconnected. Emergency diesel generator can not start manually. FP air pipe ball protection corroded through. Steering gear room emergency exit obstructed with drums. Grey water pipes made of rubber. Diesel generator fuel leaking. ME fuel leaking alarm inoperative. OFE inoperative. Valve box can be illegally connected with rubber pipe. Bilge pump connected with rubber pipe to unknown discharge. Lifeboat engine insufficient power. Abandon ship drill failed. Maintenance of ship and equipment failed.
01/02/2008
Koper / DONBATE
General cargo
7806037
2.453 / Comoros / South river shipping
Kherson
Ukraine / International Naval Survey Bureau / Detained for 16 days.
25 recorded deficiencies.
Wheelhouse bulkhead corroded through. Funnel corroded through. Two red lights for ship not under command with improper glasses. Bridge toilet bulkhead corroded through. ER door corroded through. Stern navigational light glass cracked. Both ER air vents corroded through. Alleyway bulkhead corroded through. Cabin bulkhead corroded through. Galley window frame corroded through. FW air pipe corroded through. Ballast tank 23 air pipe corroded through. Paint room air vent missing. STB chain pipe corroded through. In hold 1 STB platform corroded through. In hold 1 PS 3 beams corroded through. In hold 1 STB 2 beams corroded through.
In hold 2 hatch covers frames corroded through. In hold 2 aft 1 beam corroded through. In hold 2 entrance 1 frame corroded through. In hold 2 AFT STB hatch coaming corner plate damaged. Sludge tank, bilge tank and pumps connected with rubber pipes. On OFE three way valve missing. Food quantity insufficient. ISM _ MNC maintenance of ship and equipment failed.
05/02/2008
Koper / RANIM B
General cargo
7519787
3.501 / Cambodia / Rasha Shipping Co.
Tartous
Syria / International Naval Survey Bureau / Detained for XX days.
31 recorded deficiencies.
All navigational lights with improper glasses. Wheelhouse bulkhead corroded through. Air condition room bulkhead corroded through. Air condition room door corroded through. On EDG fuel tank QCV missing. EDG connected with rubber pipes to fuel tank. On former hospital door glass cracked. Empty cabin window glass cracked. Cabin bulkhead corroded through. Front bridge bulkhead corroded through. Hold 3 entrance cover corroded through. Hold 3 AFT air vent corroded through. In hold 3 aft 8 consecutive beams and corner plates bent. In hold 3 PS 2 consecutive frames bent.
In hold 3 aft bulkhead buckled. On hold 3 hatch covers wire leader on mast house detached. Hatch covers on hold 3 corroded through. Hatch covers on hold 2 corroded through. Hatch covers on hold 1 corroded through. In FP aft 2 frames corroded through. FP platform corroded through. Paint room air vent missing. Tk 20 air pipe corroded through. Main and auxiliary boilers inoperative. OFE outlet line improperly installed on hull. Possible illegal discharge valve fitted on hull. On all fuel tanks sounding gauges made of rubber. Sanitary facilities dirty. EFP door corroded through. ISM - NC maintenance of ship and equipment failed.
06/02/2008
Koper / DANIEL STAR
General cargo
6726199
1.996 / Syria / ISM group
Tarous
Syria / International Register of Shipping / Detained for 8 days.
21 recorded deficiencies.
Hull corroded through. Chart No 1471 missing. GMDSS batteries oxidised. Magnetic compass blocked in gimble. Funnel corroded through. ER air vent corroded through. Base plates on cargo winches on hold 2 corroded through. PS standard discharge connection improper. On hold 2 hatch covers cracked and frames corroded through. In hold 2 corner plate damaged. On windlass 1 frame corroded through. On FCSL on 1 fire hydrant hand wheel missing. Main fire line temporary repaired. Top of the FP tank corroded through. In FP several frames corroded through. Platform in FP corroded through. On hold 1 hatchcoaming frame corroded through. PS lifeboat davit corroded through. PS lifeboat davit upper pulley bent. Abandon ship drill failed. ISM - MNC maintenance of ship and equipment failed.
12/02/2008
Koper / MAYA
General cargo
7017430
2.352 / Mongolia / Mody Shipping Co.
Beirut
Lebanon / International Ship Classification / Detained for 14 days.
27 recorded deficiencies.
STB gangway platform damaged. Under gangway safety net missing. No security records and checks on access. Two ball for ship not under command to small. Funnel corroded through. Main magnetic compass sized in gimble. All air condition cables improperly installed through the bulkheads. Fore and aft anchor lights with improper glasses. Front bridge bulkhead corroded through. In hold 2 aft bulkhead frames corroded through. In hold 2 several frames corroded through. In hold 2 several frames and frame corners bent, damaged and cracked. One frame detached from hull. In hold 2 fore and aft longitudinal support corroded through. In hold 2 top of the tank No. 7 corroded through. In hold 1 fore peak bulkhead corroded through. In DG room bulkhead corroded through. On hold 1 hatch covers frames corroded through. On hold 2 hatch coaming frame cracked. EFP inoperative. Possible illegal discharge fitted. ME fuel leaking alarm inoperative. PS lifeboat can not be lowered into the sea. Abandon drill failed. ISM-MNC maintenance of ship and equipment failed. Emergency preparedness failed.
14/02/2008
Koper / ORIENTAL SUN
General cargo
7729174
8.583 / Comoros / Mansour Shipping Co.
Tartous
Syria / Russian Maritime Register of Shipping / Detained for 3 days.
18 recorded deficiencies.
Binnacle of PS gyro repetitor completely detached from deck. All air condition cables improperly installed through the bulkheads. Two red lights for ship not under command with improper glasses. STB side light and stern navigational light with improper glasses. Both ER air vent dampers sized. Electric room bulkhead corroded through. On hospital door glass cracked. Aft hold 3 hatchway entrance corroded through. Tank No 3 STB air pipe corroded through. Hold 1 air vent duct corroded through. On DG1 and DG2 fuel leaking. On DG1, DG2 and DG3 jacketed high pressure lines disconnected. Fuel leaking alarms on DG1 and DG2 improperly installed. On fuel tanks QCVs inoperative. On ME jacketed high pressure lines disconnected. OFE inoperative. Saloon bulkhead corroded through. OFE and content meter certificates missing.
19/02/2008
Koper / ARROW S
General cargo
7392608
2.765 / Mongolia / Global Management & Trading Co
Tripoli
Lebanon / International Ship Classification / Detained for 3 days.
22 recorded deficiencies.
No original SMC certificate on board. No original ISSC on board. Chart No 1471 missing. Navigational lights alarm inoperative. Two red lights for ship not under command with improper glasses. Stern anchor light with improper glass. Alleyway door threshold on upper deck corroded through. Alleyway door threshold on boat deck corroded through. PS ER air vent corroded through. Oiler's cabin bulkhead corroded through. Alleyway door on boat deck glass cracked. In hold STB 1 frame damaged. Top of the tank No. 3 cracked. Top of the tank No 4 holed in three places. In hold STB tank 3 air pipe corroded through. Tank No 4 PS fore and aft air pipes corroded through. Tank No 3 PS fore and aft air pipes corroded through. Tank No 2 PS aft air pipe corroded through. Tank No 3 STB fore air pipe corroded through. STB standard discharge connection flange improper. Valve box illegally connected with 2 rubber pipes, which permit an illegal discharge of ER bilge in the sea. ISM-MNC maintenance of ship and equipment failed.
03/03/2008
Koper / MINA
General cargo
7214818
1.923 / Cambodia / Global Management & Trading
Tripoli
Lebanon / Turkish Lloyd / Detained for 6 days.
18 recorded deficiencies.
STB side navigational light glass cracked. Wheelhouse bulkhead corroded through. Captain cabin bulkhead corroded through. Funnel corroded through. Front bridge bulkhead corroded through. Standard discharge connection improper. Sanitary facilities not hygienic. Galley hood dirty. PS hull corrosion wastage. DG2 bilge dirty. Grey water pipes in ER made of rubber. All fuel tanks QCV inoperative. ME fuel leaking alarm inoperative. STB lifeboat main rail damaged. Ship has no lifeboat with engine. Ship has no fast rescue boat. Rubber pipe connection between sludge and bilge tanks. MNC-emergency preparedness failed.
11/03/2008
Koper / YORDANKA NIKOLOVA
Bulk carrier
7813028
23.363 / Bulgaria / Navigation Maritime Bulgare
Varna
Bulgaria / Bulgarian Registry of Shipping / Detained for 3 days.
32 recorded deficiencies.
All ship's statutory certificates expired. On PS hull corroded through. Gyro compass inoperative. All navigational lights with improper glasses. Wheelhouse bulkhead corroded through. Navigational lights alarm inoperative. Alleyways bulkhead corroded through. Funnel corroded through. Battery room bulkhead corroded through. Hospital bulkhead corroded through. Aft capstan bed plate corroded through. ER air vent damper sized. Bulkhead between ER and ER air vent place corroded through. EDG room bulkhead corroded through. CQV on EDG fuel tank inoperative. Lifeboat inventory stowed in store room. In STB lifeboat 2 oars and engine exhaust pipe damaged. STB lifeboat damaged. Alleyway bulkhead corroded through. In store upper deck corroded through. Chief steward cabin bulkhead corroded through. In PS wing tank No 10 one longitudinal frame corroded through. Windlass bed plate and brake plate corroded through. DG bilge dirty. ME fuel leaking alarm inoperative. Steam collector leaking. Air condition outboard condense pipe made of rubber. On steering gear hydraulic oil leaking. Abandon drill failed. MNC-maintenance of ship and equipment failed.