Test Report
Report No.: EB/2004/10005TEST NAME: / BLUETOOTH RF-CONFORMANCE TESTING
Product Name
/ : / Bluetooth HeadsetTrade Mark / : / Formosa
Product ID / : / FB-HS01
Manufacturer / : / Formosa Teletek Corp.
Client / : / Formosa Teletek Corp.
Standard(s) / : / RF Specification 1.1 (revision 0.92)
This test report includes 3 annexes and therefore the total number of pages is 28.
TABLE OF CONTENTS
1. IDENTIFICATION SUMMARY
1.1. Test Laboratory......
1.2. Client......
1.3. Manufacturer......
1.4. Implementation Under Test (IUT)......
1.5. Testing Environment......
1.6. Limits and reservations......
1.7. Record of agreement......
2. IUT CONFORMANCE STATUS
3. STATIC CONFORMANCE SUMMARY
4. DYNAMIC CONFORMANCE SUMMARY
5. STATIC CONFORMANCE REVIEW REPORT
6. TEST CAMPAIGN REPORT
7. MEASUREMENT UNCERTAINTY.
8. OBSERVATIONS
ANNEX A
ANNEX B
ANNEX C
TRMCA01C.- Output Power
Initial Conditions......
Numeric Results......
TRMCA04C.- TX Output Spectrum - Frequency range
Initial Conditions......
Numeric Results......
RCVCA01C.- Sensitivity - single slot packets
Initial Conditions......
Numeric Results......
RCVCA01C.- Sensitivity - single slot packets
Initial Conditions......
Numeric Results......
RCVCA01C.- Sensitivity - single slot packets
Initial Conditions......
Numeric Results......
RCVCA02C.- Sensitivity - multi-slot packets
Initial Conditions......
Numeric Results......
RCVCA02C.- Sensitivity - multi-slot packets
Initial Conditions......
Numeric Results......
RCVCA02C.- Sensitivity - multi-slot packets
Initial Conditions......
Numeric Results......
1. IDENTIFICATION SUMMARY
1.1. Test Laboratory
Name: / SGS TaIWAN LTDV.A.T. : / 23928467
Address / 1F, No. 134, Wukung Road, Wuku Industrial zone
City: / Taipei county
Postal code: / 248
Country: / Taiwan, R.O.C.
Telephone: / +886-2-22993279
Fax: / +886-2-22980488
URL: /
Contact person: / Robert Chang
e-mail: /
Competences and guarantees:
SGS TAIWAN LTD. is a testing laboratory competent to carry out the tests described in this report.
In order to assure the traceability to other national and international laboratories, SGS TAIWAN LTD. has a calibration and maintenance programme for its measuring equipment.
SGS TAIWAN LTD. guarantees the reliability of the data presented in this report, which is the result of measurements and tests performed to the item under test on the date and under the conditions stated on the report and is based on the knowledge and technical facilities available at SGS TAIWAN LTD. at the time of execution of the test.
SGS TAIWAN LTD. is liable to the client for the maintenance by its personnel of the confidentiality of all information related to the item under test and the results of the test.
1.2. Client
Name: / Formosa Teletek Corp.V.A.T. : / 70814704
Address: / No. 358, Huaya 2nd Road, Gueishan shiang
City: / Taoyuan
Postal code: / 358
Country: / Taiwan, R.O.C.
Telephone: / +886-3-3280800 ext. 600
Contact person: / Kevin Wang
e-mail: /
1.3. Manufacturer
Name: / Formosa Teletek Corp.V.A.T. : / 70814704
Address: / No. 358, Huaya 2nd Road, Gueishan shiang
City: / Taoyuan
Postal code: / 358
Country: / Taiwan, R.O.C.
Telephone: / +886-3-3280800 ext. 600
Contact person: / Kevin Wang
e-mail: /
1.4. Implementation Under Test (IUT)
Product Name: / Bluetooth HeadsetTrademark: / FORMOSA
Product ID: / FB-HS01
Hw version: / 1.0
Sw version: / 1.0
Serial Number: / 003C5B014C69
Test Specification(s): / RF Specification 1.1 (revision 0.92)
PICS: / See Annex A
Description of IUT: / IUT is a headset
Sampling method: / N/A
1.5. Testing Environment
PIXIT: / See annex BPeriod of testing: / 2004-02-13
Conformance log reference: / See annex C
Retention date for log reference: / 5 years
Test Requested / RF Testing according to the RF Specification 1.1 (revision 0.92)
Means of testing identification:
Hardware: / 1. Spectrum Analyser AGILENT E7405A (Serial No. US41160416).2. Sweep Generator AGILENT 83752A (Serial No. 3601A02720).
3. RF Signal Generator AGILENT E4433B (Serial No. MY41310409).
4. Bluetooth Test Set ANRITSU MT8850A (Serial No. 6K00000302).
5. Distribution Ampliflier TIMETECH (Serial No. 126).
6. Switching Unit CETECOM BRF-SW01 (Serial No. B0005).
Software: / BITE RF Tester (SW ver 1.2.3)
Test Setup: / Connect EUT on CASIRA transient board and put it on the motherboard. Connect CASIRA to PC via RS232, connect the RF Tester to EUT via SMA connector. Using Bluesuite to let EUT enter Test mode.
Test Procedure: / The test procedure follows RF Bluetooth Test Spec 0.92
Test conditions:
NOMINAL
Temperature in the range 15ºC to 35 ºCRelative humidity in the range 20% to 75 %
Air pressure in the range 86 kPa to 106 kPa / Yes
Yes
Yes
EXTREME
MAX - MIN / NOMINALTEMPERATURE / -30.0 to 85.0 ºC / 22 ºC
VOLTAGE / 3.0 to 3.6 V. / 3.30 V.
1.6. Limits and reservations
The test results presented in this test report apply only to the particular implementation under test (IUT) declared in section 1.4 of this report, for the functionality described in the relevant Protocol Implementation Conformance Statement (PICS), as presented for test on the date(s) declared in section 1.5 and configured as declared in the relevant Protocol Implementation Extra Information for Testing (PIXIT).
This test report does not constitute or imply, by its own, to be an approval of the product by Qualification Bodies, Certification Bodies or competent Authorities.
This document is only valid if complete; no partial reproduction can be made without written approval of the Test Laboratory.
This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the Test Laboratory.
1.7. Record of agreement
The following samples were used for testing.
Internal Control No.: / Element: / Serial No.: / Date Of Reception:EB/2004/10005 / 1pcs / --- / 2004-02-10
2. IUT CONFORMANCE STATUS
This IUT has the following conformance status according to the referenced ATS specification(s).
StaticConformace errors? / NODynamic Conformance errors? / NO
Number of test cases run
Passed: / 8Failed: / 0
Total: / 8
3. STATIC CONFORMANCE SUMMARY
The PICS(s) for this IUT is consistent with the static conformance requirements in the referenced base specification(s).
The qualified PICS/PIXIT menu of the test system was defined in accordance with the client.
4. DYNAMIC CONFORMANCE SUMMARY
The test campaign did NOT reveal errors in the IUT.
5. STATIC CONFORMANCE REVIEW REPORT
PICS CORRECT / 7PICS INCORRECT / 0
PICS NOT FILLED / 0
6. TEST CAMPAIGN REPORT
The abbreviations used in the header row of the test campaign report tables are:
Temperature. / Indicate conditions of Temperature in the Test: Nominal, Maximum or Minimum.Voltage: / Indicate conditions of Voltage in the Test: Nominal, Maximum or Minimum.
Verdict: / Records the verdict assigned to each test case run to completion. Following verdicts are possible:
Pass: If the test case passed
Fail: If the test case failed
Inc: If the test case is inconclusive.
Test Case Id / Date / Time / Temperat. / Voltage / Verdict
TRMCA01C.- Output Power / 13-02-2004 / 15:43:37 / Nominal / Nominal / Pass
TRMCA04C.- TX Output Spectrum - Frequency range / 13-02-2004 / 15:44:21 / Nominal / Nominal / Pass
RCVCA01C.- Sensitivity - single slot packets / 13-02-2004 / 15:53:48 / Nominal / Nominal / Pass
RCVCA01C.- Sensitivity - single slot packets / 13-02-2004 / 16:13:52 / Nominal / Nominal / Pass
RCVCA01C.- Sensitivity - single slot packets / 13-02-2004 / 16:14:41 / Nominal / Nominal / Pass
RCVCA02C.- Sensitivity - multi-slot packets / 13-02-2004 / 16:16:22 / Nominal / Nominal / Pass
RCVCA02C.- Sensitivity - multi-slot packets / 13-02-2004 / 16:15:42 / Nominal / Nominal / Pass
RCVCA02C.- Sensitivity - multi-slot packets / 13-02-2004 / 16:16:35 / Nominal / Nominal / Pass
7. MEASUREMENT UNCERTAINTY.
According to 0.92 RF Test Specification, the following uncertainty values1,2 have been calculated and compared to the specified limits as in the table below.
Conducted measurements:
Measurement uncertainty / RF Tester uncertainty / Specification limit / Test CaseConducted measurements
Absolute RF power (wanted channel) / 1 dB / 1.2 dB / TRM01-04, 06
Absolute RF power (for unwanted emissions in the BT band) / 1 dB / 3 dB / TRC/CA/01/C
Absolute RF power (for unwanted emissions outside BT band, below 4 GHz) / 2 dB / 3 dB / TRC/CA/01/C
Absolute RF power (for unwanted emissions outside BT band, above 4 GHz) / 3 dB / 4 dB / TRC/CA/01/C
6.9.2. Relative RF power / 1 dB / 1 dB / TRM01, 03, 05, 06
6.9.4. Absolute radio frequency / 3 kHz / 5 kHz / TRM/CA/08/C
6.9.5. Relative drift radio frequency / 1 kHz / 1 kHz / TRM/CA/09/C
6.9.6. Peak frequency deviation / 2 kHz / 4 kHz / TRM/CA/07/C
Radiated measurements
Absolute RF power (wanted channel) / 4.1 dB / 6 dB / TRC/CA/01/C
Absolute RF power (for unwanted emissions between 30 MHz and 1 GHz) / 4.415 dB / 6 dB / TRC/CA/01/C
Absolute RF power (for unwanted emissions between 1 GHz and 12.75 GHz) / 4.548 dB / 6 dB / TRC/CA/01/C
Absolute RF power (for unwanted emissions between 12.75 MHz and 25 GHz) / 4.653 dB / 6 dB / TRC/CA/01/C
Note 1: All values reflect a 95% confidence level.
Note 2: All values are valid for temperatures between 20ºC and 30ºC.
8. OBSERVATIONS
There are no observations.
Report No.:EB/2004/10005
Date: 2004-02-18 / Page: 1 of 10
ANNEX A
PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (PICS)
FOR BLUETOOTH RF-CONFORMANCE
Report No.: EB/2004/10005
Item / Capability / Reference / Status / Support:Yes or No / Values
Allowed / Values
Supported
1 / Power Class
(1, 2 or 3) / A, 3 / M / YES / 1 .. 3 / 2
2 / Power Control / A, 3 / C.1 / YES / - / -
3 / 1-slot packets supported / A, 3.3 / M / YES / - / -
4 / 3-slot packets supported / A, 3.3 / O / YES / - / -
5 / 5-slot packets supported / A, 3.3 / O / YES / - / -
Supported Hopping modes / A, 2 / - / - / -
6 / 79 Channels / A, 2 / C.2 / YES / - / -
7 / France (23 Channels) / A, 2 / C.2 / NO / - / -
C.1: Mandatory to support if Power Class 1 is supported, optional to support if Power Class 2 or 3 is supported.
C.2: Mandatory to support at least one of the hopping modes.
Report No.:EB/2004/10005
Date: 2004-02-18 / Page: 1 of 3
Annex A
ANNEX B
PROTOCOL IMPLEMENTATION EXTRA INFORMATION FOR TESTING (PIXIT)
FOR BLUETOOTH RF-CONFORMANCE
Report No.: EB/2004/10005
Item / Parameter name / Type / Test case reference / Value1 / Time for TX power control / ms / TRM/CA/03/ (E/C) Power Control / 1000
2 / Inband Image frequency / MHz / RCV/CA/03/ (E/C) C/I Performance / 4
3 / Value n for intermodulation test / Integer / RCV/CA/05/ (E/C) Intermodulation Performance / 5
4 / Inquiry Scan duration / ms / TRC/CA/01/ (E/C) Out of Band Spurious Emissions / 11.250000
5 / Inquiry Scan interval / ms / TRC/CA/01/ (E/C) Out of Band Spurious Emissions / 1280.000000
6 / Type of power source / - / Chapter 6.3, RF Test specification / dc
7 / Nominal power source voltage / V / Chapter 6.3, RF Test specification / 3.30
8 / Operating temperature range / ºC / Chapter 6.4, RF Test specification / -30.0 to 85.0
9 / Extreme power source voltage / V / Chapter 6.4, RF Test specification / 3.0 to 3.6
10 / Antenna gain / dB / Chapter 6.4, RF Test specification / 0.00
Report No.:
EB/2004/10005
Date: 2004-02-18 / Page: 1 of 2
Annex B
ANNEX C
TEST RESULTS
FOR BLUETOOTH RF-CONFORMANCE
Report No.: EB/2004/10005
TRMCA01C.- Output Power
Date: 13-02-2004
Time: 15:43:37
Verdict: PASS
Initial Conditions
Spectrum Analyzer setup
Span / 0 MHzResolution bandwidth / 3.000 MHz
Video bandwidth / 3.000 MHz
Sweep time / 3500 us
Pre-trigger time / 50 us
Percent of burst / 60 %
EUT information
Power class / 2Antenna gain / 0.0 dBi
EUT address / 003C5B014C69
Connection mode / LOOPBACK
Longest packet type / DH5
Temperature / Nominal
Voltage / Nominal
Numeric Results
Center frequency / 2.402 GHzPeak Power (EIRP) / 0.50 dBm
Average Power (EIRP) / -0.43 dBm
Average Power / -0.43 dBm
Reference level / 2.70 dBm
Trigger level / 95 %
Center frequency / 2.441 GHz
Peak Power (EIRP) / 0.57 dBm
Average Power (EIRP) / -0.63 dBm
Average Power / -0.63 dBm
Reference level / 1.59 dBm
Trigger level / 95 %
Center frequency / 2.480 GHz
Peak Power (EIRP) / 1.23 dBm
Average Power (EIRP) / -0.20 dBm
Average Power / -0.20 dBm
Reference level / 1.65 dBm
Trigger level / 95 %
TRMCA04C.- TX Output Spectrum - Frequency range
Date: 13-02-2004
Time: 15:44:21
Support French frequency range: No
Verdict for Europe/USA/Japan: PASS
Initial Conditions
Europe/USA/Japan
Center low frequency / 2.402 GHzFrequency span low / 6.000 MHz
Center high frequency / 2.480 GHz
Frequency span high / 10.000 MHz
Common parameters
Resolution bandwidth / 100 kHzVideo bandwidth / 300 kHz
Sweep time / 2.000 s
Number of sweeps / 50
Reference level / 4.00 dBm
EUT information
Power class / 2EUT address / 003C5B014C69
Connection mode / LOOPBACK
Longest packet type / DH5
Temperature / Nominal
Voltage / Nominal
Numeric Results
Europe/USA/Japan
Frequency Low / 2.400816 GHzFrequency High / 2.481473 GHz
RCVCA01C.- Sensitivity - single slot packets
Date: 13-02-2004
Time: 15:53:48
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= No
Mid= Yes ( 2.441000 GHz )
High= No
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600128 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.441 GHz / 2.402 GHz / 0.00 %
RCVCA01C.- Sensitivity - single slot packets
Date: 13-02-2004
Time: 16:13:52
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= Yes ( 2.402000 GHz )
Mid= No
High= No
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600128 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.402 GHz / 2.480 GHz / 0.00 %
RCVCA01C.- Sensitivity - single slot packets
Date: 13-02-2004
Time: 16:14:41
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= No
Mid= No
High= Yes ( 2.480000 GHz )
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600128 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.480 GHz / 2.402 GHz / 0.00 %
RCVCA02C.- Sensitivity - multi-slot packets
Date: 13-02-2004
Time: 16:16:22
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= No
Mid= Yes ( 2.441000 GHz )
High= No
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600080 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Longest packet type / DH5
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.441 GHz / 2.402 GHz / 0.00 %
RCVCA02C.- Sensitivity - multi-slot packets
Date: 13-02-2004
Time: 16:15:42
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= Yes ( 2.402000 GHz )
Mid= No
High= No
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600080 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Longest packet type / DH5
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.402 GHz / 2.480 GHz / 0.00 %
RCVCA02C.- Sensitivity - multi-slot packets
Date: 13-02-2004
Time: 16:16:35
Verdict: PASS
Initial Conditions
Selected RX frequencies
Low= No
Mid= No
High= Yes ( 2.480000 GHz )
Measurement conditions
Dirty transmitter / YesBER calculated for / 1600080 payload bits
Output power / -70.0 dBm
BER limit / 0.10 %
EUT address / 003C5B014C69
Longest packet type / DH5
Temperature / Nominal
Voltage / Nominal
Numeric Results
Rx Frequency / Tx Frequency / BER2.480 GHz / 2.402 GHz / 0.00 %
Report No.:
EB/2004/10005
Date: 2004-02-18 / Page: 1 of 14