Technical Specifications –

Rehearsal Room 2

Curve and LTT cannot be held responsible for any costs incurred resulting in information, assumptions or omissions from this document. It is the responsibility of the visiting company to check critical dimensions before commissioning scenery. Please check the availability of equipment before planning productions around it.

REHEARSAL ROOM 2

CURVE TECHNICAL SPECIFICATIONS EQUIPMENT LISTS

CONTACT DETAILS

Reception0116 242 3560

Technical Co-OrdinatorSarah Spott0116 242 3586

ACCESS

PARKING

There is no private car parking on site, but Rutland Centre NCP car park is next door and costs £3.90 to park all day (please get your ticket validated at Curve Café Bar).Sat Nav users should use LE1 1TQ for Rutland Centre NCP

GET IN

Curve is accessed via Vestry Street for the purpose of unloading and get outs

Rehearsal Room two is on the first floor and accessed by a standard passenger lift measuring 900mm wide x 2100mm high x 2000mm deep

Larger items can be taken to the room via the stairs, of which the smallest opening is 1040mm wide x 2200mm high

DRESSING ROOMS

A dressing room can be provided with a bathroom, shower and lit mirrors, please request if needed. If a room adjacent to the performance space is desired there is a modest changing room leading off the lobby, please note there is no running water in this room.

STAGE

Please see attached plan.

The setting line is at 6m from the back wall along the nominal centre line.

The floor is a semi sprung dance floor, screwing down is not permitted. The stage is level with the audience and is covered with a black Harlequin dance floor.

The space has black drapes on three sides

One wall has full length ballet mirrors and a fixed ballet bar

A fire route must be maintained at no less than 1.2 metres width from the audience to the upstage right Fire Exit.

LIGHTING EQUIPMENT

Rehearsal room 2 has a fixed and pre focused lighting rig all changes made to this rig must be reinstated before departure by the visiting company. House lights may not be moved.

See attached Lighting Plan Appendix B.

If a Pre Rig is desired please contact the technical managers with your plans 4 weeks before the date of your first performance.

POWER

1 x 63 Amp 3phase supply in Lobby

6 x 13 Amp outlets in grid, non-switched.

2 x 13 Amp technical power outlets at floor level on stage

DIMMING

2 x ETC SmartpackMobile dimmer rack 24 channels total.

Dimming is distributed to the Rehearsal room via a number of integrated Soca lines

6 x socapatches to the grid

3 x socapatches to the floor level

1 Channel of Dimming is reserved for House Lights

CONTROL

1 x Programmable Lighting Control Desk ETC Element

2 x LCD Monitor 15”

PROFILE LANTERNS

12x Cantata 25/50

FRESNELS

10x Cantata Fresnels (2 without barn doors)

PARCANS

14x Parcan CP64

8 Chroma Q scrollers see Appendix B for Scroll colours

SOUND EQUIPMENTRehearsal Room 2

POWER

13amp clean power supply available inside RR2

DESK

Yamaha MG166C

OUTBOARD

Yamaha Q2031A Graphic Equaliser

Yamaha SPX1000 Effect processor

PLAYBACK

Denon DN-C550R (twin CD)

SPEAKERS

2 x RCF ART 310A (on K&M speaker stands)

APPENDIX A

Scroller Colours:

Frame 1 Open White

Frame 2 L103 Straw Tint

Frame 3 L022 Dark Amber

Frame 4 L025 Sunset Red

Frame 5 L201 Full C.T. Blue#

Frame 6 L075 Evening Blue

Frame 7 L195 Zenith Blue

Frame 8 L120 Deep Blue

Frame 9 L023 Scarlet

Frame 10 L128 Bright pink

Frame 11 L798Chrysalis Pink

Frame 12 L137 Special Lavender

Frame 13 L180 Dark Lavender