Title: A list of Approved ExTAG Decision Sheets

Circulated to: Ex Testing and Assessment Group (ExTAG)

INTRODUCTION

This document is issued to the members of the Ex Testing and Assessment Group, ExTAG,

for information purposes. It contains a list of approved ExTAG Decision Sheets.

Michel Brenon

ExTAG Secretary

Address:
SAI Global Building
286 Sussex Street
Sydney NSW 2000
Australia / IECEx Secretariat
Contact Details:
Tel: +61 2 8206 6940
Fax: +61 2 8206 6272
e-mail:
/ ExTAG Secretary
Mr Michel Brenon/LCIE
Tel:+33 1 40 95 5519
Fax:+33 1 40 95 5520
e-mail

Table of Approved ExTAG Decision Sheets

Decision Sheet No. / Standard No. / Clause/Subject / Issue Date
DS 2011/002 / IEC 60079-0: 2007 (Ed 5)
IEC 60079-0: 2011 (Ed 6)
ISO/IEC 80079-34 (Ed 1)
IECEx
OD 005-1 / Continued conformity of plastic and elastomeric materials / 2011 07
DS 2011/001 / IEC 60079-7 / Determining compliance with winding requirements for enameling / 2011 01
DS 2010/008 / IEC 60079-7 / Mechanical Security of Soldered Connections / 2010 10
DS 2010/007 / IEC 60079-1 / Sealing test of cable glands / 2010 10
DS 2010/006A / IEC 60079-0 1, -2, -5, -6, -7, -11, -15 and -18 / Dated references to IEC 60079-0 in specific protection technique parts of the IEC 60079 series / 2011 07
DS 2010/005 / IEC 60079-1: 2007 (Ed 6)
IEC 60079-1: 2003 (Ed 5) / Measurement of Pressure Rise Time in relation to determination if Pressure Piling has occurred / 2010 05
DS 2010/004 / IEC 62013-1 / Totality of equipment to be suitable for hazardous area installation when issuing IECEx certificates / 2010 03
DS 2010/003 / IEC 60079-11:2006
IEC 60079-11:200X (Ed 6)
/ Ventilation of battery containers / 2010 03
DS 2010/002 / IEC 60079-1 :2007 / Test Procedures for Breathing and Draining Devices / 2010 02
DS 2010/001 / IEC 60079-7
2001 and 2006 / Voltage values in determination of creepage and clearance distances / 2010 02
DS 2009/002 / IEC 60079-31 :2008 / Sealing requirements and terminology of cable glands / 2009 09
DS 2009/001 / IEC 60079-0 :2007 and 2004 / Method of test for measurement of capacitance of non-metallic enclosures / 2009 07
DS 2008/005 / IEC 60079-15:2005 / Non-Sparking Device / 2008 08
DS 2008/004 / IEC 60079-0:2006 / Acceptance of test data / 2008 06
DS 2008/003 / IEC 60079-15 / Assessment and testing of electronic ballasts / 2008 02
DS 2008/002 / IEC 60112 / Comparative Tracking Index
(Revision of DS 2006/001) / 2008 02
DS 2008/001 / IEC 60079-5:2007 / Apparent conflict between clauses 4.9 and 5.1.5 of IEC 60079-5:2007 / 2008 01
DS 2006/009 / Assessment of an OEM Service facility / 2006 12
DS 2006/008 / lEC 60079-11:1999
lEC 60079-11:200x Ed. 5 / Therequirements for the use of capacitors for coupling between Intrinsically Safe and Non-Intrinsically Safe circuits / 2006 12
DS 2006/007 / IEC 60079-0 / Use of non-aqueous organic salt lithium (lithium-Ion) cells / 2006 07
TC 31 /Publication /
I-SH 01 / IEC 60079-1 :2001 Ed.4 / Electrical Apparatus for Explosive Gas Atmospheres –
Part 1: Flameproof enclosures "d" / 2007 02
TC 31 /Publication/
I-SH 01
/ IEC 60079-1 :2003 Ed.5 / Electrical Apparatus for Explosive Gas Atmospheres –
Part 1: Flameproof enclosures "d" / 2007 02
DS2006/003 / IEC 60079-11 / Galvanically separating components / 2006 03
DS 2006/002 / Ex equipment where the equipment includes unspecified IECEx certified components / 2006 02
DS 2004/006A / ExTAG Decision Sheets / Procedures for use of components on end products not covered by an ExTR.
Decision Sheet revised 2010 / 2010 10
DS 2004/005 / IEC 61241-0:2004
IEC 61214.1.1:1999
IEC 60079-0:2004
IEC 60079-0:2000 / ExTAG Decision Sheets / Non-metallic parts of enclosures / 2004 11
DS 2004/004 / lEC 60079 11:1999 02 / ExTAG Decision Sheets / Segregation distances where earthed metal separates IS from Non IS circuits / 2004 11
DS 2004/003 / IEC 60079-11 / ExTAG Decision Sheets / Use of temperature coefficient for ambient temperatures above 40°C / 2004 11
DS 2004/002 / IEC 60079-11: 1999 / ExTAG Decision Sheets / Electrochemical cells / 2004 11
DS 2004/001 / ExTAG Decision Sheets / ExTAG Recommendation Sheets Additional source of information related to the application of Ex-Standards / 2004 08
DS 2003/003 / IEC 60079-11 / Assessment of infallible safety shunt assemblies / 2003 10 08
DS 2003/002 / ExTAG decisions and recommendations: Proposal for a procedure to generate, discuss and finalise them. / 2003 11
DS 2002/006 / IEC 60079 11: 1999 02 / Clause: 7.1
Rating of components / 2002 10 21
DS 2002/004 / IEC 60079 11: 1999 02 / Clause: 7.4.2,10.9.3
Electrolyte leakage from cells and batteries / 2002 10 21
DS 2002/003 / IEC 60079 11: 1999 02 / Clause: 7.11, 7.4.8
Rating of components for battery chargeable equipment / 2002 10 21
DS 2002/002A / IEC 61779 1: 1998 04 / Clause: 3.5
Diffusion Gas Sensing Heads
This Decision Sheet was revised to take into account changes within the new edition of the Standard. / 2008 03 31
DS 2002/001A / IEC 60079-11:1999-02 / Clauses: 5.4, 7.1, 7.4
Electrochemical sensors
This Decision Sheetwas revised (2007-09-25) to take into account editorial changes / 2007 09 25