/ CFASEnterprises Inc.
After Market Utility Power Equipment Brokerage
Mailto:
Turbine URL:
Reciprocating URL:
GTG_110B_RR Twin Pacs

THREE (3) 23.6 MW (ISO) GAS TURBINE GENERATING SETS

Price : U$S 3.8 Million each, “as is” Europe

Each gas turbine generating unit comprises two Rolls-Royce Avon gas generators and one GEC power turbine driving an air cooled ac generator for 23.6 MWe, 11,000 volt, 50 Hz base load electrical power supply at ISO conditions (15 Deg c , 1.013 bar).

DUTYThe units are suitable for base, peak, or standby supply.

FUELLight distillate. The units can be adapted to dual liquid/gas or gas firing.

STARTING110v DC starter motor making the units independent of external electrical supplies for start-up.

The aero derivative gas generators and free power turbine makes the units suitable for combined cycle application with or without supplementary firing.

SCOPE OF SUPPLY FOR EACH GAS TURBINE SET

  • Two Rolls-Royce Avon aero derivative gas generators.
  • G.E.C. two stage free power turbine.
  • G.E.C air cooled, 11,000v, 50 Hz alternator.
  • Lubricating oil package.
  • ]Fuel control system package
  • Control and alarm panels.
  • Motor control centres.
  • DC batteries and chargers.
  • Coolers, pumps, motors and pipework for lubricating and cooling air systems

Not available

Turbine house overhead crane.
Turbine exhaust systems.
Batteries and charger systems.
Fuel oil storage tanks.
Fuel oil pipework and valve system to the gas turbien building.
11 kV switchgear.
Other control panels

Details Avon Gas Generators

Gas generator type:R-R Avon 1533-75L axial flow, seventeen stage compressor with a

three stage turbine.

Temperature:Exhaust control585 deg C

base (max)

Exhaust control640 deg C

Peak.

Starter:112 V d.c. electric motor

Length:3.56 m

Width:0.99 m

Weight:1,724 Kg

Fuel specification:B.S. 2869, class A light distillate.

Lubrication oil’Grade 5 synthetic lubricant.

Power Turbine

Type:Type G.E.C. EA2, independent two stage axial flow.

Rotation:Clockwise viewed from generator end.

Speed:3000 rpm

Length:4.0 m

Width (including ducts):6.0 m

Weight (including bedplate):50,800 Kg

Lubricating oil:Light and medium oils to BS 489 depending in location.

A.C. Generator

Type:G.E.C. cylindrical rotor, brushless, air cooled synchronous generator.

Rotation:Clockwise looking from exciter end

RatingBase load:23.6 MW at 15 deg C ambient temperature

Peak:29.0 MW 1.013 bar atmospheric pressure

Volts:11,000

Phase:3

Cycles:50 per second

Length (including exciter):8.0 m

Width:3.0 m

Weight (including exciter):69,000 Kg

History and Operating Hours

The gas turbines were installed by GEC Gas Turbines Limited in the late 1970’s at a 3,300 MW oil fired power station in England to provide black start capability for the main sets and for standby peak lopping duty.

Unit Number / Total Operating Hours / Total Number of Starts / Comments
2 / 1911 / 991 / Unit is mothballed, has not been run since 31/3/91
3 / 1809 / 872 / Unit is mothballed, has not been run since 31/3/91
5 / 1601 / 619 / Unit is mothballed, has not been run since 31/3/91