CABLE HARNESSES 12

No SCEM 04.70.07.010.0

------

/ Logistics Group
Material Management Section
TECHNICAL APPENDIX
N° 585
Date : 29 October 2004
HARNESS CABLE II/III+CONNECTORS
N° SCEM 04.70.07.010.0
Ref. LG/mm

CABLE HARNESSES 12

No SCEM 04.70.07.010.0

------


C O N T E N T S

1 GENERAL 2

1.1 SCOPE 2

1.2 CLASSIFICATION 2

2 APPLICABLE DOCUMENTS 3

3 CABLE HARNESS CONSTRUCTION 3

3.1 CABLES 4

3.1.1 MPPBF1 : 4

3.1.2 MPP2 : 5

3.2 CONNECTORS 6

3.2.1 Type II to PP1 (end inside the experiment detector) 6

3.2.2 Type III to PP3 (end outside the experiment detector) 6

3.3 SPLICING 7

3.3.1 Materials (heat shrinkable tubes): 7

3.3.2 Splicing procedure : 8

3.4 TESTING 9

3.5 MARKING 9

3.6 PACKAGING 9

4 QUALITY CONTROL 9

4.1 GENERAL 9

4.2 INSPECTION STAGES 10

4.2.1 Qualification inspection 10

4.2.2 Quality conformance inspection 10

4.2.3 Packing inspection 11

1  GENERAL

1.1  SCOPE

This specification concerns the realisation of cable harnesses, including cutting cables to specified lengths, supply and mounting of connectors, realisation of splicing connections, electrical and mechanical tests and marking.

1.2  CLASSIFICATION

All standardized cables at CERN have an internal reference known as the SCEM number.

SCEM / Designation
04.70.07.010.0 / HARNESS CABLE II/III+CONNECTOR

2  APPLICABLE DOCUMENTS

This specification makes reference to the following publications :

CERN/FC/1814-II (1975) General conditions of CERN contracts

CERN/IS41 (1995) The Use of Plastic and other Non-Metallic

Materials at CERN with respect to Fire Safety

and Radiation Resistance

IEC 60189-1 (1992) Low frequency cables and wires with PVC

insulation and PVC sheath

Part 1: General test and measuring methods

IEC 60811 Common test methods for insulating and sheathing materials of electric cables

IEC 60885 Electrical test methods for electric cables

IEC 60885-1 (1987) Part 1 : Electrical tests for cables, cords and wires for voltages up to and including

450/750 V

3  CABLE HARNESS CONSTRUCTION

The cable harness is a composite system made of two cables assembled together with a splicing connection and defined connectors on both ends.

MPBF1 is a thin flexible cable that is intended to be installed inside the experiment detector, where space and radiation doses are critical. For this reason AWG20 wires are insulated with polyimide tape KAPTON 100 HN. The other wires are insulated with SILTEM STM 1500. The splicing connection and MPP2 part of the cable harness will be installed outside the detector

3.1  MPPBF1

Pos 1 / Quad of insulated wires
o  2 wires of AWG20
o  2 wires of AWG28 / Yellow, Red
Black, Green
Pos 2 / Quad of insulated wires
o  2 wires of AWG20
o  2 wires of AWG28 / Black, Green
Yellow, Red
Pos 3 / Twisted pair of AWG28 / Brown, Natural
Pos 4 / Twisted triple of AWG28 / Green, Natural, Brown
Pos 5 / Twisted triple of AWG28 / Blue, Green, Orange
Pos 6 / Drain wire of AWG24, non insulated / n.a.
Pos 7 / Shield of aluminium polyester tape in contact with the drain wire / n.a.
Pos 8 / Outer jacket / Red
Construction details :

4x AWG 20

Conductor : AWG 20, 19x0,20 mm tinned copper

Conductor diameter 1.0mm

Insulation : Polyimide tape KAPTON 100 HN

Nominal diameter 1.10 mm

2x(3x28)+4x28 AWG 50 V

Conductor : AWG 28, 7x0,127 mm tinned copper

Conductor diameter 0.39mm

Insulation : SILTEM STM 1500, nominal thickness 0,13 mm

Nominal diameter 0.64mm

2x 28 AWG 500 V

Conductor : AWG 28, 7x0,127 mm tinned copper

Conductor diameter 0.39 mm

Insulation : SILTEM STM 1500, nominal thickness 0,20 mm

Nominal diameter 0.79 mm

Overall Shield

Polyester tape 0,023 mm + Al/polyester tape 9/12 micron with tinned copper drain wire 7x0,20 mm in contact with Al. Nominal diameter 4.55 mm

Outer sheath

LSHF compound Megolon S304 , nominal thickness 0.4 mm

Colour red RAL 3000

Nominal diameter 5.40 mm (5.50mm max)

Electrical and physical characteristics

Electrical resistance at 20°

§  AWG 20 < 33.33 Ohm/km

§  AWG 28 < 222.22 Ohm/km

Test voltage 50V wires:

§  Conductors/conductors : 1kVac - 1min

§  Conductors/shield : 0,75 kVac -1min

Test voltage 500V wires :

§  Conductors/conductors : 1,5 kV ac - 1min

§  Conductors/shield: 1 kV ac - 1min

Other characteristics

Weight : 52.6 kg/km

Bending radius static : 45 mm

Working temperature range static : from -20 to +80°C

3.2  MPP2 :

Pos 1 / Quad of insulated wires
o  2 wires of 1.0mm2
o  2 wires of 0.14mm2 / Blue, Red
White, Green
Pos 2 / Quad of insulated wires
o  2 wires of 1.0mm2
o  2 wires of 0.14mm2 / Grey/Black, Grey/Red
White/Brown, White/Blue
Pos 3 / Twisted pair of 2 wires of 0.14mm2 / White/Grey, White/Violet
Pos 4 / Twisted triple of 3 wires of 0.14mm2 / White/Black, White/Red, White/Green
Pos 5 / Twisted triple of 3 wires of 0.14mm2 / Yellow, Brown, Black
Pos 6 / Drain wire of 0.75mm2, non insulated / n.a.
Pos 7 / Flame retarding polyester-glass-fibre-polyester-tape / n.a.
Pos 8 / Shield of aluminium polyester tape in contact with the drain wire / n.a.
Pos 9 / Outer jacket / Grey
Construction details :

4x 1mm2

Conductor : 1 mm2, 19x0,25 mm tinned copper

Conductor diameter 1.25mm

Insulation : High density polyethylene, nominal thickness 0,375 mm

Nominal diameter 2.00mm

2x(3x0,14)+4x0.14 mm2 50 V

Conductor : 0.14 mm2, 7x0,16 mm tinned copper

Conductor diameter 0.48mm

Insulation : Hight density polyethylene, nominal thickness 0,25 mm

Nominal diameter 1.00mm

2x0.14 mm2 500 V

Conductor : 0.14 mm2, 7x0,16 mm tinned copper

Conductor diameter 0.48mm

Insulation : Low density polyethylene, nominal thickness 0,375 mm

Nominal diameter 1.25mm

Overall Shield

Polyester tape 0,023 mm + glass fibre tape + Al/polyester tape 25/23 micron with tinned copper drain wire 19x0,25 mm in contact with Al. Nominal diameter 7.60mm

Outer sheath

LSHF compound, nominal thickness 0.4 mm

Colour grey RAL 7035

Nominal diameter 10.40 mm

Electrical and physical characteristics

Electrical resistance at 20°

§  1mm2 < 21.5 Ohm/km

§  0.14mm2 < 142.86 Ohm/km

Test voltage 50V wires:

§  Conductors/conductors : 1kVac - 1min

§  Conductors/shield : 0,75 kVac -1min

Test voltage 500V wires :

§  Conductors/conductors : 1,5 kV ac - 1min

§  Conductors/shield: 1 kV ac - 1min

Other characteristics

Weight : 151.5 kg/km

Bending radius static : 65 mm

Working temperature range static : from -30 to +80°C

3.3  CONNECTORS

The harnesses will be fitted with following connectors :

3.3.1  Type II to PP1 (end inside the experiment detector)

o  20-position, double-row, right angle connector from JST (or equivalent if 100% identical and interchangeable) as signal, HV, shield & control line connector, composed of :

§  Housing part number : JST # SHDR-20V-S-B (1 mm pitch, double row, 20 circuit housing)

§  Header part number : JST # SM20B-SRDS-G-TF (1 mm pitch, double row, side entry, 20 circuits, shrouded header)

§  Crimp pins part number : JST # SSH-003GA-P0.2 (crimp pins for SHDR housing)

JST SM20B SRDS G TF
1
2 / ILEDa (VCSEL) / Pos 4 / Green
3 / ClockSel / Pos 4 / Brown
4 / PinBias / Pos 5 / Green
5 / Reset / Pos 4 / Natural
6 / Temp1 / Pos 5 / Blue
7 / VddSense / Pos 1 / Black
8 / VddRet Sense / Pos 1 / Green
9 / VccSense / Pos 2 / Yellow
10 / VccRet Sense / Pos 2 / Red
11 / Drain / Pos 6 / n.a
12 / Temp2 / Pos 5 / Orange
13
14 / HV ret / Pos 3 / Brown
15
16
17
18
19 / HV / Pos 3 / Natural
20

o  Right angle connector from FCI (or equivalent if 100% identical and interchangeable) as power line connector, composed of:

§  Housing part number : FCI # 65239-002

§  Header part number : FCI # 76383-302

§  Crimp pins part number : FCI # 76347-311

FCI 65239-002
pin / pin / Line / wire group / color
2 / VccRet / Pos 2 / Black
1 / Vcc / Pos 2 / Green
4 / VddRet / Pos 1 / Yellow
3 / Vdd / Pos 1 / Red

3.3.2  Type III to PP3 (end outside the experiment detector)

o  Combination of D-sub/mixed layout connector from CONEC (or equivalent if 100% identical and interchangeable). The connector is composed of :

§  Housing part number : CONEC # 3017W5PBK99A1OX (plug)

§  Header part number : CONEC # 131C11019X (plugs 4x: A1, A2, A3, A4) and CONEC # 132J14019X (socket: A5)

§  Crimp pins part number : CONEC # 13nC11019X (A1-A2-A3-A4) and CONEC # 13nJ11019X (location A5)

Combination of D-sub/mixed layout connector from CONEC

Type III (PP3 end)
CONEC 17W5
pin / pin / Line / wire group / colour
A1 / Vdd / Pos 1 / Red
A2 / VddRet / Pos 1 / Blue
1 / VddSense / Pos 1 / White
7 / ClockSel / Pos 4 / White/Black
2 / Reset / Pos 4 / White/Red
8 / VCSEL / Pos 4 / White/Green
3 / VddRet Sense / Pos 1 / Green
9 / PinBias / Pos 5 / Yellow
4 / Temp2 / Pos 5 / Brown
10 / Temp1 / Pos 5 / Black
5 / VccSense / Pos 2 / White/Blue
11 / VccRet Sense / Pos 2 / White/Brown
6 / Drain / Pos 6 / n.a
12 / HV ret / Pos 3 / White/Violet
A3 / Vcc / Pos 2 / Grey/Red
A4 / VccRet / Pos 2 / Grey/Black
A5 / HV / Pos 3 / White/Grey

The state of the art rules shall be applied to ensure the electrical continuity, insulation resistance and dielectric strength. The insulation resistance and dielectric strength of the original cables and connectors must be guaranteed, referring to IEC 60189-1 sub clauses 5.2 and 5.3

3.4  SPLICING

The splicing connections shall be made between MPP2 cables and MPPF1 cable. These cables are supplied by CERN.

The overall diameter of the spliced section must not exceed 170% of cable section.

The splice should withstand a pull force of 100N without breaking single wires.

The insulation resistance and dielectric strength of the original cables must be guaranteed, referring to IEC 60189-1 sub clauses 5.2 and 5.3.

The splice joint shall add less than 10% to the total resistance of the cable harness.

3.4.1  Materials (heat shrinkable tubes):

The nominal radial thickness of the insulation shall be adapted to the required operating voltage (see sub-clause 3.2)

Since the installed cable harnesses will be exposed to ionizing radiation, it is important to keep the electrical and mechanical characteristics of the insulating material up to the expected accumulated dose of 200Gy.

The heat shrinkable tubes shall fulfil the CERN safety instruction IS41

3.4.2  Splicing procedure :

A) Strip the cables from the side where the insulation can be unwrapped easily, being careful not to tear it.

B) Thread the heat shrinkable sheath over the cable grey type III and over the red cable type II.

C) Unroll the shielding foil and place it behind the cables without cutting it.

D) Unroll and cut the paper tissue of the grey cable type III.

E) Cut the strings of the grey cable type III beginning at the edge of the shielding and thread the heat shrinkable sleeves in well defined way and then strip them until the plating is completely exposed. Thread an additional special heat shrinkable sheath over the HT strings.

F) Connect the two cables according to the colour reference table by cutting the red cable type II to the desired length and then pull the sleeves back.

G) Roll the two insulation foils together and solder the two ends together.

H) Wrap the two insulation foils around the strings starting with the red cable type II and scotch tape it.

I) Pull the heat shrinkable sheaths back, the assembly is done.

splice connection / Type II / Type III
MPPBF1 / MPP2
Line / wire group / color / wire group / color
Vdd / AWG20 / Pos 1 / Red / Pos 1 / Red
VddRet / AWG20 / Pos 1 / Yellow / Pos 1 / Blue
VddSense / Pos 1 / White / Pos 1 / White
ClockSel / Pos 4 / Violet / Pos 4 / White/Black
Reset / Pos 4 / Red / Pos 4 / White/Red
VCSEL / Pos 4 / Dark blue / Pos 4 / White/Green
VddRet Sense / Pos 1 / Green / Pos 1 / Green
PinBias / Pos 5 / Yellow / Pos 5 / Yellow
Temp2 / Pos 5 / Brown / Pos 5 / Brown
Temp1 / Pos 5 / Black / Pos 5 / Black
VccSense / Pos 2 / Blue / Pos 2 / White/Blue
VccRet Sense / Pos 2 / Natural / Pos 2 / White/Brown
Drain / Pos 6 / n.a / Pos 6 / n.a
HV ret / Pos 3 / Pink / Pos 3 / White/Violet
Vcc / AWG20 / Pos 2 / Green / Pos 2 / Grey/Red
VccRet / AWG20 / Pos 2 / Black / Pos 2 / Grey/Black
HV / Pos 3 / Orange / Pos 3 / White/Grey

3.5  TESTING

Each cable harness shall be 100% tested prior to shipping:

o  Insulation and dielectric strength

o  Linear resistance

o  Electrical continuity

o  External dimensions

o  Pull force test

A complete test report, according to DIN 50049 - 3.2C, shall be written for each cable harness. A copy of the test report shall be included in the packaging.

3.6  MARKING

Each cable harness end shall be labelled with unique labels supplied by CERN:

The labels A1 and A2 shall bear the same reference.

The cable harness number shall be referred in the individual test report.

3.7  PACKAGING

Each patch cable shall be individually packed. The packing must assure an effective protection against the wear and tear transport and handling damage. In order to facilitate the installation on site, cable harness shall be packed in a way that give easy access to the connector type II (end of MPPBF1) part as this shall be installed first.