Hybrid Solar PCU

/ Our Grid synchronized solar power inverter is an advanced 4 quadrant bidirectional inverter that helps satiate the power demands of residential / industrial sectors in developing nations. It consists of state-of-the-art ruggedized grid feeding inverter along with high efficiency solar charge controller. Using this system excess power can be exported to grid and at the same time can be provided back for critical loads via battery storage. It comes in all capacities ad battery voltages to cater to all kinds of applications.
The same technology can be used for battery-less systems of pure grid export type. It can be synchronized both with mains and DG to support the loads along with EB / DG supply.

  • True 4 quadrant rugged IGBT based inverter
  • Programmable current control for Grid synchronized mode
  • UPS mode of operation at load end
  • Excellent yield from solar through MPPT based charge controller
  • Customized for operation with or without battery
  • Excellent performance up to 50ºC
  • Galvanic isolation using power transformer
  • Available in all capacities / battery voltages
  • Digital display with fault and energy logging
  • Remote monitoring over RS-458 and internet

  • Single Phase Off Grid Solar Power Conditioner
/
  • Solar Hybrid DC Power Supply Unit

  • 3 Phase Solar Grid Export Inverter
/
  • Intelligent String Monitor

  • 3 Phase Solar Power Conditioner
/
  • Array Junction Box

  • Single Phase Grid Interactive Solar Power Conditioner
/
  • MPPT Charge Controller

Technical Details
Nominal Capacity / 1-3 KVA / 4-6 KVA / 7.5-12.5 KVA / 12.5-25 KVA
Nominal DC Voltage / 48V / 96 / 120V / 120V / 240V / 240V
Overload Capacity / 150% for 60 seconds, 125% for 10 seconds
Efficiency / >90% at rated load, nominal input voltage
Switching Devices / MOSFET / IGBT / IGBT
A / Solar Charger Option
Topology / MPPT (Buck Type)
Switching Device / IGBT
MPPT Range / 60-128V MP / 120-195V MP / 155-255 MP / 300-510V MP
Max PV Voltage / 150V / 230V / 300V / 600V
B / Grid Interactive Mode
AC Voltage Range / 230V AC, +/- 15%
AC Frequency Window / 47-53 Hz
C / Stand Alone UPS Mode
Nominal Output AC / 240V, 50 Hz (Factory adjustable for +/- 10%)
Output Regulation / +/- 2%
Frequency / 50 Hz +/- 0.1 Hz (Factory Adjustable)
Current THD / <3%
Changeover Time / 5-10ms
System Bypass / Internal Automatic Bypass on Shutdown
D / Gen-set Interactive Option
Control Method / AC Interactive
Start Conditions / Grid Failure and Low Battery State of Charge
Stop Conditions / Grid Recovery or Low Gen-set Loading
Start / Stop Signals / Potential Free Contact Provided
E / Protection / Display / Communication
Protection / Inverter Over/Under Voltage
Battery Over / Under Voltage
Mains Over / Under Voltage
Mains Over / Under Frequency
Battery / PV Reverse Polarity
Inverter Overload / Short Circuit
Display / Inverter Voltage & Current
Battery Voltage & Current
PV Voltage, Current, Generation
Mains Voltage & Current
Communication / RS 232 / RS 458 / GPRS based monitoring
Operating Temperature / 0-50 ºC

Page 1 of 9