WP3215 COMSILENT N2
BOOSTER DATA SHEET
WP3215CS Data Sheet Nitrogen Booster Data SheetFinal Operating Pressure / Speed / UNITS
1770 RPM
(60 Hz)
Flow & Power / 1450 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 10.4-13.5 / SCFM
11 / HP
2900 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 10.0-13.0 / SCFM
11.2 / HP
4000 PSIG Outlet Pressure
(0 – 4.5 PSIG Regulated Inlet Pressure) / 9.3-12.1 / SCFM
11.4 / HP
Technical Specifications / Motor rating / 12 (8.7 KW) / HP
Current @ 460 Volts / 14.4 / Amps
Weight / 1135 / Pounds
Noise level @ 3 ft / 72 / dB(A)
Heat dissipation / 34,000 / Btu/hr
Cooling air needed / 1,000 / CFM
Residual oil content at gas outlet (without filtration) / < 3 / mg/m3
Delta temperature (gas oultet vs. ambient) / 18 / °F
Operational ambient temperature range / 40-110 / °F
Operating pressure range / 1450-4000 / psig
Oil sump capacity / 6.1 / Quarts
Dimensions (L x W x H) / 60 X 31 X 62 / Inches
Cooling method / Air-Cooled
Drive type / Direct Drive
Stages/Cylinders / 3/3
*All data is with 5 % tolerance and is related to ambient conditions of 68 ° F and 14.7 PSIA.
Package Includes:
- Feed tank run-permissive sensor (supplied loose)
- Inlet Buffer Tank and Regulator Assembly
- Intercoolers and aftercooler
- Oil and water separators after the 1st,2nd and 3rd stages
- Safety valve after each stage
- 1st,2nd, and 3rd stage pressure gauges
- Solenoid valves (115 V / 60 Hz) for automatic drainage of the separators
- Unloaded starting relief and automatic condensate drain system
- Condensate demister to easily dispose of condensate drainage
- Assembly of compressor and electric motor
- Resilient mounts including drainage hoses and air/gas outlet hose
- 460/3/60 electric motor with IP 55 (TEFC) protection
- Non-return valve mounted to air/gas outlet hose
- Low oil pressure shutdown switch
- High air/gas temperature shutdown switch mounted at the air/gas outlet of the compressor
- Final gas filtration for oil free gas delivery
- Compressor control system (including motor starter) for starting/stopping the compressor, and monitoring the oil level, air/gas outlet temperature and outlet pressure of the compressor
- Complete package wired and mounted on a skid, and enclosed in a sound dampening canopy
- Air/gas pressure sensor for automatic start/stop
Standard warranty is 15 months from date of shipment or 12 months after initial installation and start-up, whichever comes first. Ask your Sauer USA representative if your project requires an extended or alternative warranty period.
Sauer Electronic Compressor Control (ECC technology):
Electronic Compressor Control (ECC) advanced embedded control solution:
MountingIntegral
Power:6.1HP
Power Supply:60Hz / 3Ph
Control voltage:115V ac
Disconnect mains supply:Red handle, yellow locking collar
Emergency Stop:Latched pushbutton
Protection:IP 54
Power supply to processor:24 V ac
Operation:
- AUTO automatic - Start / Stop ( based on suction (feed) and final system pressure)
- HAND manual Start – auto Stop / manual Stop (e.g. Servicing)
Control:
- Compressor solenoid drain valve (NO)
- Auto-unloaded Start (programmable - ‘normal’ 15 s)
- Periodic drainage (programmable - ‘normal dry gas’ every 30 min. for 5 s)
- Feed gas Start / Stop (gas suction pressure sensor control)
- Suction gas solenoid shut-off valve (NC)(open on Start/close on Stop)
- Final system Stop / Start(gas final pressure sensor control)
User Interface:
Custom backlit LCD: 2 LED Indicators
-STATUS: Green
-FAULT: Red
Keypad: 7 tactile push buttons
- START(I)Manual Start
- STOP (O)Manual Stop
- RESET (//)Reset and clear faults
- ESCAPE (C)Step back one level
- MINUS/DOWN (▼) Scroll down menu
- PLUS/UP(▲) Scroll up through menu
- ENTER(◄┘) Confirm selection
Display:
- Operating gas pressure
- Hours run
- Service hours
- Gas temperature
- Oil pressure
Error(s) - shutdown/Alarm/Diagnostics:
- Emergency Stop
- E-Motor over-load
- Low oil lubricating pressure
- Low / high gas suction pressure
- Oil/water (condensate) level alarm
- High gas temperature
- High final gas pressure
- Potential free contact(s)
Optional equipment:
- Final receiver packages with the necessary components supplied
- Diesel motor driven
- Modified for 50 Hz power supply
- Customized controls for user specified monitoring and operation
- Weather resistant canopy
- Complete package rated for installation in a hazardous location (Class 1 Division 2, or Class 1 Division 1)
Sauer Compressors USA custom engineers solutions for our customers. Please inquire about options you may require which are not listed.