Balco, Inc. CE Series Silicone Compression Seal Wall Joint Covers

CE-100SX through CE-500

Choose the applicable items from each section below

1.06 SYSTEM DESCRIPTION

A.  Joint cover system consisting of a continuous, extruded, chambered silicone compression seal

bonded to the substrate using a silicone adhesive/sealant

B.  Joint covers shall permit unrestrained movement of the joint without disengagement of

the cover. Joint covers must conform to the requirements of ASTM E1399.
1. Specify x-axis joint movement. (Joint expansion and contraction; Specify for each building

level: wall)

2. Specify y-axis joint movement. (Joint shear movement; Specify for each building level:

wall)

3. Specify z-axis joint movement. (vertical shear movement; Specify for each building level:

wall)

C.  Fire rated joint cover systems shall have been tested by and shall be listed with an

independent, nationally recognized testing and listing. Fire resistant joint covers shall be rated for [1 hour] [2 hours] [not less than the fire rating of the adjacent construction]

2.02 MATERIALS

A. [Expansion] [Seismic] joint cover systems shall be Balco, Inc. CE Series

1.  Face Seals: Shall be ASTM D2000 4GE709M flexible Silicone

2.  Fire Barrier: choose the appropriate fire barrier(s) from the list below

Metaflex 5000 MetaBlock tested in accordance with UL 2079 and/or ASTM E1966, *

*including hose stream test, where applicable, at the full rated period

3.  Silicone adhesive/sealant shall have the following properties:

a. ASTM C 661 Durometer Hardness, Shore A points 15

b. ASTM D 412 Ultimate Tensile Strength,

maximum elongation psi (kg/mm2) 100 (0.070)

c. ASTM D 412 Elongation, maximum percent 1600

d. ASTM C 794 Peel Strength lb/in (kg/cm) 25 (4.46)

e. ASTM C 1135 Tensile Adhesion,

1). at 25% extension psi (kg/mm2) 15 (0.010)

2). at 50% extension psi (kg/mm2) 20 (1.015)

f. ASTM C 1135 Weathering, after 22,400 hours in

QUV Weatherometer ASTM G 53

at 25% extension psi (kg/mm2) 30 (0.021)

at 50% extension psi (kg/mm2) 40 (0.028)

g. ASTM C 719 Joint Movement Capabilities

Extension percent +100

Compression percent -50

h. ASTM C 1248 Staining, after 14 days of

50% compression, at 70°C (158°F) on concrete,

granite, limestone and brick None

4. Accessories, sealant and other materials required for complete installation in

accordance with the manufacturer’s written installation instructions.

2.03 FINISHES (Select all applicable items in this section)

A. Silicone Compression Seal shall be [black] [precast white] [natural stone] [grey] [bronze] [custom color as selected by the architect]

B. Silicone Sealant shall be [standard color as selected by the architect] [custom color as selected by the architect]