ARCHWAYS DIGITALFIBERGLASSREINFORCEDPOLYMER(FRP) RAINSCREEN CLADDING
SECTION 07 44 50
FIBERGLASS REINFORCED POLYMER (FRP) PANELS
PART 1 - GENERAL
1.1SECTION INCLUDES
- Design, Engineering, manufacturing and erection of fiberglass reinforced panels. Delegated Design of Exterior Fiber Reinforced Polymer Composites Panel Profiles.
- Attachment, embedded and anchoring hardware.
- Strong back and panel stiffeners.
- Aluminum integral panel support.
1.2RELATED SECTIONS
- Section 07 05 43Cladding Support Systems
- Section 01 74 19 Construction Waste Management
- Section 014339 Mock-Ups
- Section 014400 Quality Assurance
1.3REFERENCES
- Abbreviations:
- FRP: Fiber reinforced polymer (FRP) composites.
- Reference Standards:
- ASTM International (ASTM)
- ASTM A27 - Standard Test Method for Steel Castings, Carbon, for General Application.
- ASTM A36 - Standard Specification for Carbon Structural Steel.
- ASTM A47 - Standard Specification for Ferritic Malleable Iron Castings.
- ASTM A283 - Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates.
- ASTM A307 - Standard Specification for Carbon Steel Bolts and Studs, 60,000 PSI Tensile Strength.
- ASTMA325-StandardSpecificationforStructuralBolts,Steel,HeatTreated,120/105ksiMinimum TensileStrength.
- ASTMA580-StandardSpecificationforStainlessSteelWire.
- ASTMA666-StandardSpecificationforAnnealedorCold-WorkedAusteniticStainlessSteelSheet,Strip,Plate,andFlatBar.
- ASTMD638:TestMethodforTensilePropertiesofPlastic.
- ASTMD695:TestMethodforCompressiveStrengthofRigidPlastics.
- ASTMD790:TestMethodsforPropertiesofUnreinforcedandReinforcedPlasticsandElectricalInsulatingMaterials.
- ASTME84:TestMethodforSurfaceBurningCharacteristicsofBuildingMaterials.
- InternationalBuilding Code(IBC),2012
- ASCE/SEI7-10:MinimumDesignLoadsforBuildingsandOtherStructures
1.4PERFORMANCEREQUIREMENTS
- GeneralPrescriptiveRequirements:
- RefertorequirementsinSection07 05 43–Cladding Support Systems.
- Allbracketsoutsidethevaporbarriershallbestainlesssteeloraluminum.
- Allexternalareasofthecladdingshallbeaccessibleformaintenanceandrepair.
a)Loadstobeadjustedasnecessaryforthetypeandorientationofmaintenanceequipmentanticipated.TheContractWorkshallsustainsafely,andwithoutdamage,accessandspecifiedmaintenanceloads.
- Incorporateseparatorstopreventbimetalliccorrosionwhen deemed necessary by manufacturer.
B.GeneralPerformance:
- Complywithperformancerequirementsspecified,asdeterminedbypreconstructiontestingrepresentingthoseindicatedforthisProject.
- ContractWorkshallasspecified:
a)Withstandandaccommodatethestressesandmovementsinducedbythespecifiedcambers,estimateddeflections,relativedeflectionsandthelongtermmovementsassociatedwiththesettlementofthefoundations,oranyothermovementsofthestructure,changesintemperatureandchemicalchanges.
b)Includesuitableallowancesforthespecifiedconstructiontolerances.
c)Withstandthespecifieddeleteriousanddegradingeffectsofradiationfromthesun,weathering,atmosphericpollution,vandalism,vermin,fungiandothergrowthsfortherequiredservicelifedescribedhereinwithoutmaintenanceinexcessofroutinecleaningandminorrepairs.
d)Havearesistancetocombustionandfirespreadappropriatetoeachpart.
e)CleaningandmaintenanceoftheWorkshallbecarriedouteasily,withoutinterferingwiththefunctionofthebuilding.
- Failureshallincludethefollowing:
a)Structuralfailureofcomponentsresultingfromforceswithinspecifiedlimits.
b)Thermalstressestransferringto/fromtheContractWorktothebuilding structure.
c)Excessivedeflections.
d)Noiseorvibrationcreatedbythermalandstructuralmovements.
e)Looseningorweakeningoffasteners,attachments,andothercomponents.
f)De-lamination.
g)Failureoftouch-upfinishtomatchfactoryfinish.
h)Stainingofadjacentcomponentsorwettingofinteriorbuildingcomponents.
i)Discoloration,fading,chalking,excessivenon-uniformity,pitting,cracking,peeling,corrosion,orcrazingoffinish.
1)ThetermsbelowusedinconjunctionwithfinishGuaranteearedefinedasfollows:
2)“Resin color retention”: Change of color should be maximum 5 delta E over and above the initial 1.5 delta E allowable under section 074450, 2.1, A, 3, over the equivalent of 5 years.
3)"Excessive non-uniformity":meansnon-uniformfadingduringtheperiodoftheguaranteetotheextentthatadjacentpartshaveacolordifferencegreaterthantheoriginalacceptablecolorrange.
4)"Willnotpitorotherwisecorrode":meansthereshallbenopittingorothertypeofcorrosionoffinishdiscerniblefromadistanceoften(10)feet,resultingfromthenaturalelementsintheatmosphereattheProjectsite.
j)Failuretofulfillotherspecifiedperformancerequirements.
1.5ADMINISTRATIVEREQUIREMENTS
- Pre-installationMeeting:
- Conveneapre-installationmeetingpriortocommencinginstallation.
- RequireattendanceofpartiesdirectlyaffectedbyworkofthisSection.
- Reviewconditionsofinstallation,installationprocedures,andcoordinationrequiredwithrelatedwork.
1.6SUBMITTALS
- ProductData:SubmitstandardFRPcompositesproductdata.
- ShopDrawings-Drawingsshallindicatethefollowing:
- Fabricationshapesanddimensions.
- Surfacefinish.
- Color.
- Thicknesses.
- Anchoringdetails.
- Methodsofsupport.
- Connectionsbetweenfabricationsandadjacentbuildingcomponents.
- Fabricationdetails.
- Requiredclearances.
- Liftinganderectiondetails.
- AllowancesforFRPcompositesfabricationandadjacentmaterialtolerances.
- Certificates:
- Manufacturer'squalificationstatement.
- Installer'squalificationstatement.
- CurrentvalidthirdpartyproductListingandLabelinginaccordancewiththerequirementsintheInternationalBuildingCode.Labelsaffixedtoproductsmanufacturedanddeliveredtothejobsite.
- ListofmanufacturerspersonnelwithcurrentvalidcertificationintheAmericanCompositesManufacturersAssociation-CertifiedCompositesTechnicianprogram.
- QualityControlProgram:ManufacturersinternalQualityControlManualandQualityAssuranceProcedures.
- Delegated-DesignSubmittal:ForFRPcompositesassembliesindicatedtocomplywithperformancerequirementsanddesigncriteriaincludeanalysisdataandcalculationssignedandsealedbythelicensedprofessionalengineerresponsiblefortheirpreparation.
- Manufacturer'sInstructions-Submitmanufacturer'sprintedinstallationinstructions,maintenanceinstructionsandrecommendationsforproductdelivery,storageandhandling.
- CloseoutSubmittals:
- Submitmanufacturer'swarrantyforproject.
1.7QUALITYASSURANCE
- Qualifications:
- Manufacturer:
- ProvideproductsmanufacturedbyafirmspecializinginthefabricationofFRPcompositesproductswithaminimumoffiveyears’ experience.
- ShallbememberofAmericanCompositesManufacturersAssociation(ACMA)andhaveaCertifiedCompositesTechnician(CCT)onstaff.
- ShallhaveaListingandLabelingprogramindicatingcompliancewithflamespreadindexrequirementsperSection2612(/FiberReinforcedPolymer",2012IBC.
- Shallhaveaninternalqualitycontrolprogram.
- Installer:ApprovedbythemanufacturerfortheinstallationofcomponentsprovidedunderthisSection.
- Welders:QualifiedbytheAmericanWeldingSociety"StandardQualificationProcedure"forarcorgasweldingofconnectingstructure.
- Mock-ups(RepresentativeSample): Buildmock-upstoverifyselectionsmadeunderSamplesubmittalsandtodemonstrateaestheticeffectsandsetqualitystandardsformaterialsandexecution.
1.8ENVIRONMENTAL QUALITY ASSURANCE
- Provide materials and products with recycled content as specified.
- Applicable LEED Credits:
- Materials & Resources Credit 4, Recycled Content
1.9DELIVERY,STORAGEANDHANDLING
A.Transport,handle,andstoreFRPcompositesproductsaccordingtomanufacturer'srecommendationsandinamannerthatpreventscosmeticandstructuraldamage.
B.Inspecteachcomponenttoensurethatitcomplieswithspecifiedrequirements.
C.Verifythatareaswherepanelswillbeunloadedareclearofobstructionsandwell-drained.
D.BraceandstabilizeFRPcompositesproductstopreventwarping.
E.ProtectFRPcompositesproductsfromdamagebyretainingshippingprotectioninplaceuntilinstallation.
1.10WARRANTY
- WarrantFRPcompositesproductstobefreefromdefectsduetomaterialsandworkmanshipforfiveyears.
PART2–PRODUCTS
2.1MATERIAL
A.MoldedExteriorSurface:
- Coating:UVinhibitedinmoldcoatingandpaint.
- TextureandColor:Sandblasttospecifiedtextureasshowninapprovedsample.
- MatchResinwithManufacturer’s approvedsampletowithinlaboratorytoleranceof1.5deltaE,accordingtoCIED2000(InternationalCommissiononIllumination).
- Procureaggregatefromsamesourceasformock-uptoavoidvariationfromapprovedmock-up.
- Procure aggregateinonebatchandmixbatchtoreducecolorvariation.
B.Laminate:
- Matrix:
- Resin: Manufacturer'sstandardproduct
- FillersandAdditives: Asrequired
- FiberReinforcement:
- FiberType: E-glassfiber
- FiberArchitecture:TBD
1)Orientedstrandglassfibers;multi-axial
- Glasscontent(FiberVolumeFraction):
1)Standard:Minimum20percent.
2)FilledSystems: Minimum15percent.
2.2DESIGNCRITERIA
- ConformtoperformancerequirementsidentifiedforexteriorwallinSection07 05 43 – Cladding Support System.
- Installedproductsshallbecapableofwithstandingpositiveandnegativewindpressurewithoutstructuralfailure,cracking,crazing,permanentdistortionordisplacement.
- ProvisionsforMovement:
- Designanddetailanchorages,connections,andjointstoallowfordimensionalchangesoftheFRPcompositesproduct.
- FRPComponentFireTestResponseCharacteristics:
- FRPcompositesusedasexteriorcomponentsshallmeettherequirementsof2012,IBCSection2603.5and2612forcombustibility.
- NFPA268-Ignition;doesnotexhibitsustainedflaming.
- NFPA285-FirePropagation
- ASTME84-ClassA25orless.
2.3FABRICATION
- General: FabricateandfinishFRPcompositespanelprofilesandaccessoriesatthefactorytogreatestextentpossible,bymanufacturer'sstandardproceduresandprocesses,asnecessarytofulfillindicatedperformancerequirementsdemonstratedbylaboratorytesting.Complywithindicatedprofilesandwithdimensionalandstructuralrequirements.
- Fabricatepanelprofilesinaccordancewithapprovedshopdrawings.
- LaminateThickness.TBD
- Embedanchorsintopanelprofilesperapprovedshopdrawings.
- Afterremovingcomponentfrommold,prepareexposedsurfaceforspecifiedfinishtexture.
- Seamsormoldlinesshallbefilledwherenecessary,groundsmooth,andfinishedtomatchsurroundingsurfaces.
- Providemajorribsandintermediatestiffeningribsasindicatedonapprovedshopdrawings.
- Identification:
a.Identifyeachpartwithapermanentserialnumber.
b.Numberpartstocoordinatewithshopdrawings.
- Cureandcleancomponentspriortoshipmentandremovematerialwhichmaybeincompatiblewithadjacentbuildingmaterials.
- FinishTexture;exposedsurfaces: PerfinishonNFPA285testpanelorequal,asapprovedbyArchitect.
- Finishtextureshallbeconsistentandevenoverexposedsurfacestomatchapprovedsamples.
D.Applycoatingstoaproperlypreparedsurfaceinaccordancewithcoatingmanufacturersinstructions.
- Integrallymoldedgelcoatthickness: AsperManufacturer'sstandard.
- FurnishaccessoriesforsecuringFRPcompositespanelprofilestosupportingandadjacentconstruction.
- FabricationTolerances:
- TotalThickness:Plusorminus1/16inch.
- Length:Plusorminus1/8inchin10feet.
- Locationofaccessories,andotherconnectinghardware,plusorminus1/4inch.
- VariationfromSquare:plusorminus1/4inchin10feet.
- Outofplanevariationplusorminus1/4inchin10feet.
- Warpingorbowingplusorminus1/4inchinany10squarefootarea.
2.4ACCESSORIES
- MetalAnchorsandFasteners:Asrecommended bymanufacturerandconformingtothefollowingstandards:
- Stainlesssteel:ASTMA666,Type 300 series.
- FireBlocking:Incompliancewithapplicablecodeandasindicatedonapprovedshopdrawings.
- Sealant: compatiblesiliconesealant. Compatibilityandadhesiontestingrequiredoncladdingsubstrates.
- Adhesive: Asrecommendedbymanufacturer.
PART3-EXECUTION
3.1EXAMINATION
- Observefieldconditionsthatbuildinglines,grades,andelevationswillallowproperinstallationofFRPcompositesproducts.
- Verifythatsupportframinghasbeenconstructedtoallowaccurateplacementandalignmentofanchorbolts,plates,dowels,orotherconnectionstostructure.
- Priortoinstallationverifyallfielddimensions. Reportdiscrepancieswhichcouldaffectinstallation. Donotproceedwithinstallationuntildiscrepanciesarecorrected.
- Beginningofinstallationmeansacceptanceofexistingconditions.
3.2ERECTION
- Installcomponentsinaccordancewithmanufacturer'sinstructionsandapprovedshopdrawings.
- LiftingandPositioning:LiftFRPcompositeswithsuitableliftingdevicesatpointsindicatedonapprovedshopdrawings.
- Setcomponentslevel,plumb,square,andtruewithintheallowabletolerances.
- Temporarilysupportandbracepanelsasrequiredtomaintainposition,stabilityandalignmentuntilpermanentconnection.
- Donotallowcomponentstobecut,trimorinanywaychangetheshapeorconnectionlocationswithoutexpresswrittenpermissionordirectionfromthemanufacturer. Providerevisedcalculationsandshopdrawingsintheeventarevisionisrequired.
- Fastening:
- FastenFRPcompositesproductsasshownonapprovedshopdrawings.
- PerformarcorgasweldinginaccordancewithFRPcompositesmanufacturer'sinstructionsandapprovedshopdrawingsusingmaterialscompatiblewiththebasematerial.
- Tolerances:
- Warpage:Maximumpermissiblewarpageofonecorneroutoftheplaneoftheotherthreeshallbe1/8inchperfoot,or3/8inchtotalafterinstallation.
- Bowing:LessthanL/200withamaximumof1whereListhepanellengthinthedirectionofthebow.Differentialbowingbetweenadjacentmembersofthesamedesignshallbe1/4inch.
- WidthofJoint:shallallowformanufacturing,thermalandengineeringtolerances,butnolessthan1/2inch.
- MaximumOffsetfromTrueAlignment:1/4inchin20feet.
- MaximumVariationfromTruePosition:1/2inchin20feet.
- Gaptolerancesbetweenjointsforpaneldimensionsof:
- Lessthan10feet:plusorminus3/16inch.
- 10feetto20feet:plusorminus1/4inch.
- Greaterthan20feet:plusorminus5/16inch.
3.3CLEANING
- CleaninstalledproductsusingcleaningmethodsandmaterialsapprovedbyFRPcompositesmanufacturer.
3.4PROTECTION
- ComplywithFRPcompositesmanufacturer'srecommendationsandinstructionsforprotectinginstalledproductsduringconstructionactivities.
3.5CONSTRUCTION WASTE MANAGEMENT
- General: Comply with the requirements of Section 01 74 19 - Construction Waste Management for removal and disposal of construction debris and waste.
- Separate and recycle waste materials to the maximum extent possible.
ENDOFSECTION
Page 1of 9