Siemens Energy & Automation, Inc.

Process Instrumentation Business Unit

CoC Ultrasonic Flow

155 Plant Avenue ▪ Hauppauge ▪ New York 11788 ▪ USA ▪

Phone: (631)231-3600 ▪ 1-800-275-8479 ▪ Fax: (631)231-3334

email: ▪

SITRANS FUG 1010 Gas Flow Meter

Application Information Form

Field Clamp-on Meter

Siemens Energy & Automation manufactures a complete line of Gas Flow Meters. Completing this form will permit Siemens Energy & Automation Application Specialists to recommend the most suitable system for your applications.

(Refer to applicable product data sheet)

▪ Company Name:______
▪ Street:______
▪ City:______
▪ State/Province: ______
▪ Postal code/Zip:______
▪ Country:______/ ▪ First Name:______
▪ Last Name:______
▪ Phone:______
▪ Fax: ______
▪ Email:______
▪ Date: ______mm/dd/yyyy
▪ Required Meter Delivery Date: ______

FOR MULTIPLE SITES, PLEASE FILL OUT ADDITIONAL FORMS IF DIFFERENT THAN ALREADY STATED.

Site Name ______Site # of

1)Application Information:

  1. FlowRange: Min Normal Max Units:
  2. Operating Pressure:

Min Normal Max Units:

  1. Operating Temperature:

Min Normal Max ºF ºC

  1. Gas Type: Natural Gas Flare Gas, Process Gas Specify Type:

Please specify approx. CO2%

  1. Gas Condition: Wet-Gas%Moisture, Pulsating Flow

2)Measurement Section Description:

  1. Nominal Pipe Outer Diameter: in. mm
  2. Nominal Pipe Wall Thickness or Schedule:in. mm or sch.
  3. Pipe Material: Carbon Steel, Stainless Steel, Duplex, Plastic, Other -
  4. Liner Material: ______Thickness: in. mm
  5. If known, Straight Run: Diameters Upstream, Diameters Downstream

NOTE – Please describe or sketch piping layout on Page 3.

3)Equipment Requirements: Flow Transmitter

  1. Enclosure: NEMA 4X/IP65, Compact NEMA 7/IP66, Wall MountNEMA 7/IP66
  2. Power: 90 – 240 AC, 9 – 36 VDC ---- For DC; Positive ground Negative ground
  3. Requires armored cable: No Yes*
  4. Cable Length between Flow Transmitter and Flow Sensor Location on Pipe Feet Meters
  5. Check output that applies: RS232 Digital Pulse* Mod Bus** Ethernet** RS485**

* Extra Cost Option

** Not Available in Compact NEMA 7

4)Environmental Conditions: (check best description and describe in detail on page 3)

  1. Sensors: IndoorsOutdoors

Corrosive EnvironmentOffshore, Submersible

  1. Transmitter:Local Mounting at Sensor location Remote Mounting in Protected area.

Transportable (kit) Degrees F C Ambient Temp

5)Performance Requirements: Important – Describe Upstream and Downstream pipe conditions on page 3.

  1. Desired Accuracy: % of rate, Repeatability: %
  2. Flow Direction: Uni-directional, Bi-Directional

6)Safety Approval:

Safety Approvals Required: No Yes If yes, choose

Factory MutualorCSA: Class I, II Div 1Class I, II Div 2

or

ATEXIf ATEX, complete the following:

FLOWDATA COMPUTERTRANSDUCERS

AREA CLASSIFICATION (ZONE RATING)AREA CLASSIFICATION (ZONE RATING)

Category 1, Zone 0, GasCategory 1, Zone 0, Gas

Category 2, Zone 1, GasCategory 2, Zone 1, Gas

Category 3, Zone 2, GasCategory 3, Zone 2, Gas

Safe Area, No ClassificationSafe Area, No Classification

APPARATUS GAS GROUPINGAPPARATUS GAS GROUPING

Group IIC Group IIC

Group IIB + H2 Group IIB + H2

Group IIB Group IIB

Group IIA Group IIA

Group I Group I

TEMPERATURE CLASSTEMPERATURE CLASS

T1: 450°C T1: 450°C

T2: 300°C T2: 300°C

T3: 200°C T3: 200°C

T4: 135°C T4: 135°C

T5: 100°C T5: 100°C

T6: 85°C T6: 85°C

7)Gas Compressibility Compensation:

a)Require: Actual Flow Rate or Standard Volume Flow Rate or Mass Flow Rate

b)If Standard Volume or Mass Flow, then indicate the desired compensation approach:

Compensation to be performed within Flowmeter (without Flow Computer)? Yes

If Yes, specify preferred compensation method (valid for fixed gas composition only):

AGA 8 Detailed* AGA 8 Gross* Other:

Compensation to be performed using external Flow Computer (Omni or equivalent)? Yes

If Yes, specify compensation method (AGA8 Detailed, NX19, etc):

c)Check all that apply:

Available 4-20 mA temperature Signal? ...... No Yes

If No, Siemens Energy & Automation supplied Temperature?*No Yes

Available 4-20 mA Pressure Signal? No Yes

If No, Siemens Energy & Automation supplied Pressure Transmitter?*No Yes

Available Flow Computer?No Yes

If No, Siemens Energy & Automation supplied Flow Computer?*No Yes

* Extra Cost Option

If req’d, Cable Length between Flow Transmitter and Pressure Transmitter Feet Meters

If req’d, Cable Length between Flow Transmitter and Temp Transmitter Feet Meters

8)If Known, Include:

Mole Fraction List: / Methane / % / Carbon Dioxide / %
Ethane / % / Nitrogen / %
Propane / % / Hydrogen / %
Isobutane / % / Water / %
n-Butane / % / Oxygen / %
Isopentane / % / Hydrogen Sulfide / %
n-Pentane / % / Carbon Monoxide / %
n-Hexane / % / Other / %

CC-543 Rev2 Page 1 of 3

Describe and/or Insert a photo or a sketch of the application and Up/Downstream piping conditions. (Remember to include valves, elbows, other flowmeters, etc.): Simply copy and paste into this table. Bitmaps should be no larger than 640 X 480 Pixels.

Signature______Date______

CC-543 Rev2 Page 1 of 3