SECTION 07760
ADJUSTABLE PEDESTALS FOR TERRACES
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2012 - 2016 ARCAT, Inc. - All rights reserved
** NOTE TO SPECIFIER ** Buzon Pedestal International; adjustable pedestals for terraces.
This section is based on the products of Buzon Pedestal International, which is located at:
Prolongement rue de l'Abbaye, 134
Z.I des Hauts Sarts, zone 1
Herstal, Belgium B-4040
Buzon East Phone: 646-929-4318
Buzon East Fax: 212-243-2868
Buzon West Phone: 425-530-5414
Buzon West Fax: 866-521-0440
Email:
Web Site:
Since 1987, Buzon Pedestal International has been Europe's leading manufacturer of screwjack polypropylene pedestals. The reputation of BUZON® pedestals is the fruit of extensive experience and a willingness to satisfy the exacting demands of Architects, Specifiers, quantity surveyors and construction professionals, offering a wealth of construction and technical information. Our team of designers and engineers are ready to give you immediate support for your projects and construction sites all over the world.
For exterior and interior locations, commercial, industrial installations such as food storage; where regular cleaning and drainage is required. At roof level, pedestals can be used to support decking or pavers to contain and protect the services for ventilation, water supply and lighting. Services running in cavity below can be easily accessed.
Pedestal spacing options allow for complex layouts, abutments, penetrations and edge details. Typical application types include: raised access decks at ground or roof level for commercial and other sectors; support for visible bottom surface of water features over service voids; industrial floors using grid systems; temporary exhibitions, podiums, plinths and raised false floors.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Roof decking pedestals as shown on Drawings and specified herein. Include related attachments, and accessories.
1.2 RELATED SECTIONS
** NOTE TO SPECIFIER ** Delete sections below not relevant to this project; add others as required.
A. Section 02780 - Unit Pavers.
B. Section 04220 - Concrete Unit Masonry.
C. Section 04400 - Stone Assemblies.
D. Section 06150 - Wood Decking.
E. Section 06500 - Structural Plastic Decking.
F. Section 06730 - Composite Decking.
G. Section 07500 - Membrane Roofing.
H. Section 07720 - Roof Walkways.
I. Section 07760 - Roof Pavers.
J. Section 09690 - Access Flooring.
1.3 REFERENCES
** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.
A. ASTM E 108/UL 790 - Standard Test Methods for Fire Tests of Roof Coverings
B. Belgium (CRIF) Centre De Recherches Scientifiques ET Techniques Del Industrie Des Fabrications: Test Report No. GT 7660/01.
1.4 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer's data sheets for each assembly specified, including but not limited to:
1. Performance characteristics.
2. Preparation instructions and recommendations.
3. Storage and handling requirements and recommendations.
4. Installation Instructions.
C. Method Statement: Prior to the installation of adjustable pedestal decking systems, Contractor shall submit an installation ' method statement' setting out the installation procedure for approval.
** NOTE TO SPECIFIER ** The contractor assumes the responsibility for and must take into consideration the structural capability and adequacy of the structure to carry the dead and live load weights involved, and that the density of any insulation is satisfactory to resist crushing and damaging the waterproofing membrane. Consult manufacturer and project engineer regarding: when spacer tab condition or design requires spacing between decking tiles or pavers other than standard spacing required by manufacturer; when considering use for in application other than a raised deck such as interior floors or stairs; when required pedestal height exceeds safe limits as determined by manufacturer; when pedestal load capacity exceeds maximum listed; when anticipating installation of items with excess weight on top of deck; when using Buzon pedestals on soil; when greater pedestal load capacity is required. Delete options for configuration and associated data not required.
D. Engineering Calculations:
1. Structural Analysis: Provide test report indicating the structural capability and adequacy of the roof decking pedestal assembly to carry the dead and live loads imposed by the roof decking.
2. Density of Insulation: Sufficient to resist crushing and damaging waterproofing membrane.
E. Laboratory Test Reports: Exterior fire-test exposure reports performed by independent testing agency indicating that roof decking pedestals comply with specified fire resistance classification.
F. Shop Drawings: Provide shop drawings showing details including but not limited to plans, elevations, sections, fabrication, installation, anchorage, interface of the work of this section with the work of adjacent trades and indicating dimensions, tolerances and finishes.
** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.
G. Selection Samples: For each assembly type, two complete sets of samples representing manufacturer's full range of available product assembly types.
H. Verification Samples: For each finish product specified, two samples representing actual product assembly types specified.
** NOTE TO SPECIFIER ** SUSTAINABILITY: LEED: Use the following paragraphs when LEED Submittals are required. Delete if not required.
I. LEED Submittals: In accordance with LEED Requirements:
1. Submit required letters, calculations, spreadsheets and templates prepared by Architect for submitting to USGBC for Credit Interpretation Requests.
2. Submit Project Materials and Cost Data: Provide statement for total cost for building materials used for Project.
** NOTE TO SPECIFIER ** SUSTAINABILITY: LEED 2009 (first option below) and LEED v.4 (second option below).
3. Materials and Resources Credit: MRc.4 Recycled Content: Submit product data and certification letter(s) of proposed materials with recycled content:
a. Showing their cost and percentages by weight of post-consumer and pre-consumer recycled content.
4. Materials and Resources Credit: MRc Building Product Disclosure and Optimization - Sourcing of Raw Materials: Submit product data and certification letter(s) of proposed materials with recycled content:
a. Showing their cost and percentages by weight of post-consumer and pre-consumer recycled content.
1.5 QUALITY ASSURANCE
A. Single Source Requirements: To the greatest extent possible, provide pedestals and ancillary products specified in this section from a single manufacturer.
B. Manufacturer's Qualifications: Successfully engaged in the manufacture of adjustable pedestals for terraces for at least 25 years.
C. Installer Qualifications: Successfully engaged in installation of adjustable decking systems for at least 5 years; capable of estimating, building from working CAD details or plans, determining elevations and properly handling materials in pedestal decking assembly.
1. Method Statement Submission: Prior to the installation of the adjustable pedestal decking systems, the installer shall submit an installation ' method statement' setting out the installation procedure for approval.
** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.
D. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1. Finish areas designated by Architect.
2. Do not proceed with remaining work until workmanship is approved by Architect.
3. Rework mock-up area as required to produce acceptable work.
1.6 DELIVERY, STORAGE AND HANDLING
A. Inspect delivered materials upon arrival to ensure they are undamaged, in good condition and as specified.
B. Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards.
C. Store products indoors in manufacturer's or fabricator's original containers and packaging, with labels clearly identifying product name and manufacturer. Pedestals are delivered boxed in cardboard cartons. These cartons should be stored in dry conditions and should not come into contact with rain or damp conditions. Protect from damage.
1.7 PROJECT CONDITIONS
A. Surfaces to receive roof decking pedestals shall be broom clean, frost free, and free of dirt, oil or any rough foreign matter, which may impair the proper installation of the roof decking pedestals.
B. Confirm that substrates have positive slope and provide adequate drainage in accordance with applicable building codes.
C. Do not install roof decking pedestals over any roofing insulation with a density of less than 414 kPa (60 psi).
1.8 SEQUENCING AND SCHEDULING
A. Conference: Convene a pre-installation conference to establish procedures to maintain optimum working conditions and to coordinate this work with related and adjacent work.
1.9 WARRANTY
A. Manufacturer's Warranty: Pedestal system shall remain free from manufacturing defects for a period of ten years from date of Substantial Completion.
B. Contractor's Warranty: Contractor shall warrant that their work will remain free from defects of labor and materials for a period of two years from date of Substantial Completion.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Buzon Pedestal International SA: Z.I. des Hauts-Sarts, Zone I Prolongement de la rue l'Abbaye, 134, B-4040 Herstal, Belgium; Contact: Laurant Buzon; Tel: +32-4-248 39 83; Fax: +32-4-264 82 38; Web: HYPERLINK "
B. Buzon USA West: Contact: Erik Nelson; Tel: 503-954-3336; Fax: 866-521-0440; Email: ; Web: HYPERLINK "
C. Buzon USA East:16 W. 56th St.; New York, NY 10019; Contact: Mufdi Siraji; Tel: 646-929- 4318; Fax: 212-243-2868; Email: ; Web: HYPERLINK "
D.
** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.
E. Substitutions: Not permitted.
F. Requests for substitutions will be considered in accordance with provisions of Section 01600.
2.2 PERFORMANCE REQUIREMENTS
A. Exterior Fire-Test Exposure: Provide roof decking pedestal system listed as Class A fire resistance rating when tested in accordance with ASTM E 108 or UL 790 by an independent testing agency acceptable to authorities having jurisdiction. Identify products with appropriate markings of applicable testing agency.
B. Compression Resistance: Compression Resistance: Roof decking pedestal system shall be capable of withstanding minimal breaking loads up to 1000kg (2204 lbs.).
C. Recycled Content: Pedestal system shall contain 80% post-industrial recycled content and be 100% recyclable.
** NOTE TO SPECIFIER ** Delete if not required.
2.3 ADJUSTABLE PEDESTALS (DPH SERIES)
A. Fix /Adjustable Screwjack Pedestal System:
1. DPH-Series as manufactured by Buzon Pedestal International.
2. Compliance:
** NOTE TO SPECIFIER ** Loading Test Positions: The following loading data for pedestals with loads applied at various positions on the load bearing top surface of the pedestals. 1/1 is load evenly applied across entirety of the load- bearing surface; 1/2 is load applied to half of the load- bearing surface; 1/4 is load applied to one quarter of the load-bearing surface. The tests were carried out on a universal testing machine, type Instron 1185 n degrees H - 4573, with a capacity of 100 kN, fitted with a 100 kN force transducer No. 2518 - 201. The loading speed was 10 mm/min. The mean RUPTURE value, expressed in daN or en lbf, is the result of carrying out the test on 3 supports at different heights. If any option other than ' Standard, talc-loaded...' is selected above for ' Pedestal Component Materials' then delete data listed under ' Configuration' for ' Loading Data.'
a.Testing Agency: Belgium (CRIF) Centre De Recherches Scientifiques ET Techniques Del Industrie Des Fabrications.
a. Test Method: Universal testing machine, Instron type.
b. Test Report: No. GT 7660/01.
c. Safety Factor for Pedestrian Terraces: Divide the following values by 2.
d. Safety Factor for Raised False Floors: Divide the following values 4.
B. Fix / Adjustable Height Pedestal: Suitable for all types of roof decks and terraces using precast concrete pavers and other heavy materials.
1. Composition: Five piece, interlocking, multi-threaded unit consisting of slope corrector, mounting head, height extension coupler, adjustment ring clamp coupler, and support base.
a. Slope Corrector: Slope compensation system, adjustable in increments of 0.5% up to a maximum 5% slope. Slope corrector is mounted to the pedestal head with fixing clips, and is formed from two cylindrical parts that allows compensating for 1 to 5% slopes to provide a level mounting head; 255mm (10 inch) diameter; 12mm (1/2 inch) thickness to be added to the adjustable height of the pedestal.
b. Pedestal Head: Large support surface with reinforcement ribs; screwed directly into the coupler or adjustment ring clamp; fitted with slots to receive cylindrical plate with 4 paver positioning blades of various thicknesses to achieve an open gap between pavers. Including locking safety clips to prevent total unscrewing of the pedestal head.
c. Height Extension Coupler: One-piece extension coupler with upper part threaded to receive additional extension couplers or the pedestal head, and lower part threaded to screw into the adjustment ring clamp coupler. Including safety clips to prevent total unscrewing of the pedestal head or ring clamp. Lock keys keep the pedestal height in place after height adjustment.
d. Adjustment Ring Clamp Coupler: Factory assembled ring clamp coupler, factory fitted onto the support base; ring clamp consists of reverse threading cylinders with multiple inner and outer threads, and fitted with safety locks to prevent total unscrewing of the components.
e. Support Base: Cylindrical support base with reinforcement ribs, threaded to receive ring clamp coupler. Support base can be placed or fixed to a solid substrate, or partially cut away for positioning against a wall. Includes holes at bottom for drainage.
2. Height Range: Fix (17 mm; 21/32 inch) and (28mm;1 3/32 inch) or infinitely adjustable by rotation of each pedestal component, using variable height support bases ranging from 17 to 175mm (5/8 to 6- 7/8 inch), and multiple height extension couplers up to a maximum height of 1073 mm (42 1/8 inch).
3. Material: Ultraviolet (UV) stabilized, talc-filled, high density, copolymer polypropylene, weather, sea salt, and chemical resistant; 3 to 4.5mm (1/8 to 3/16 inch) thickness.
4. Temperature Range: Resistant from -30 degrees C to 90 degrees C (-22 degrees F to 194 degrees F).
C. Mounting Head Accessories: Spacer tabs, rubber shims and mounting plates with paver positioning blades, support pins, and joist supports that can be clipped to the head of the pedestal to accommodate the selected roof decking material.
D. Perimeter Containment And Support
1. The complete assembly of roof decking pedestals and pavers shall be restrained at the perimeter of the walk deck area to resist lateral movement. 3mm standard allowed at all edges, total 6mm allowed max.
2. Cumulative movement in excess of 6 mm (1/4 inch) will void the manufacturer's warranty.
** NOTE TO SPECIFIER ** Delete if detailed component listing is not required.
E. Components:
** NOTE TO SPECIFIER ** Fill in blank below with custom material designation or delete line as applicable. If any option other than ' Standard, talc-loaded...' is selected below for ' Pedestal Component Materials' then delete data listed under ' Loading Data' for ' Pedestal Configuration' (below). Pedestals in polypropylene are not designed to support machines or equipment that may subject them to vibration. Custom options available such as transparent units for display or exhibition areas; contact manufacturer for details. Delete options for Pedestal Component Materials not required.
1. Pedestal Component Materials: Custom, ______
2. Pedestal Component Materials: As scheduled and indicated on Drawings.
3. Pedestal Component Materials: Standard, talc-loaded polypropylene copolymer with minimum 80 percent recycled CCP material, 20 percent Talc, 2 percent UV, Master Batch black, 100 percent recyclable; suitable for use in temperatures from -30 degrees C to 120 degrees C (-22 degrees F to 250 degrees F).
4. Pedestal Component Materials: Transparent units.
5. Pedestal Component Materials: Transparent polycarbonate.
6. Ancillary Application Materials:
a. Accommodates metal grid systems, fiberglass grid systems, timber-style decking, square-shaped or rectangular-shaped stone, concrete, natural stone, terrazzo, ceramic, composite pavers as approved by manufacturer.
b. Do not use Buzon Deck Supports over insulation less than 20 psi or with low density polystyrene insulation.
** NOTE TO SPECIFIER ** Adjusting ring is incorporated from model DPH-5 upwards; slope corrector is incorporated into pedestals from model DPH-4 upwards; slope corrector and numerous fixing accessories are available to support all types of structures, and can be used on all models from DPH-0 to DPH-3. Delete configurations not required.
7. Configuration: As scheduled and indicated on Drawings.
8. Configuration: DPH-0.
** NOTE TO SPECIFIER ** Delete options for nominal fixed height not required.
a. Nominal Fixed Height: As scheduled and indicated on Drawings.
b. Nominal Fixed Height: Standard, 17 mm.
c. Nominal Fixed Height: With PH5 slope corrector, 27 mm.
d. Diameter: 170 mm.
e. Surface Area: 227 cm2.
f. Load Data: Mean value of load.
1) At Position 1/1: 5450 daN (12154 lbf).
2) At Position 1/2: 2820 daN (6289 lbf).
3) At Position 1/4: 1460 daN (3256 lbf).
9. Configuration: DPH-1.
** NOTE TO SPECIFIER ** Delete options for nominal fixed height not required.
a. Nominal Fixed Height: As scheduled and indicated on Drawings.
b. Nominal Fixed Height: Standard, 28 mm.
c. Nominal Fixed Height: With PH5 slope corrector, 38 mm.
d. Diameter: 170 mm.
e. Surface Area: 227 cm2.
f. Load Data: Mean value of load.
1) At Position 1/1: 5120 daN (11418 lbf).
2) At Position 1/2: 2325 daN (5185 lbf).
3) At Position 1/4: 1325 daN (2955 lbf).
10. Configuration: DPH-2.
** NOTE TO SPECIFIER ** Delete options for nominal height range not required.
a. Nominal Height Range: As scheduled and indicated on Drawings.
b. Nominal Height Range: Standard, 35 mm - 53 mm.
c. Nominal Height Range: With PH5 slope corrector, 44 mm - 62 mm.
d. Top Diameter: 145 mm.
e. Top Surface Area: 165 cm2.
f. Base Diameter: 200 mm.
g. Base Surface Area: 314 cm2.
h. Load Data: Mean value of load.
1) At Position 1/1 at 45 mm Height: 1420 daN (3667 lbf).
2) At Position 1/2 at 45 mm Height: 1295 daN (2888 lbf).
3) At Position 1/4 at 45 mm Height: 645 daN (1438 lbf).
4) At Position 1/1 at 53 mm Height: 1360 daN (3033 lbf).
5) At Position 1/2 at 53 mm Height: 875 daN (1951 lbf).
6) At Position 1/4 at 53 mm Height: 375 daN (836 lbf).
11. Configuration: DPH-3.
** NOTE TO SPECIFIER ** Delete options for nominal height range not required.
a. Nominal Height Range: As scheduled and indicated on Drawings.