Adding a new Probe location to the CEA system

This document is a general guide to add a new location/interface type to the system. It is highly recommended to use an existing data source / location (of the same interface type) as a reference.

1.- Create a new Data Source

- Go to Data Collation & Loading -> Data Sources

- Click on the “+Add” button

In the General tab:

- Provide an Id: Unique identifier (no spaces)

- Provide a Name: User friendly name

- Specify a Type: Normally this will depend on the manufacturer of the probe

- Time Zone: Time zone used to encode data in the file

- Check “Active”

In the Alert tab:

-Check “Alert on Delay”

-Provide a Warning Threshold: Time when a Data Source will be considered late

-Provide an Error Threshold: Time when a Data Source will be considered missing.

-Click the “Save” button.

2.- Create a new Location

- Go to Data Collation & Loading -> Collectors -> Locations

- Click on the “+Add” button

In the General tab:

- Provide an Id: Unique identifier (no spaces)

- Provide a Name: User friendly name (normally landing zone + interface type)

- Select the data source created in step 1.

- Specify a Type: Indicate the type of collector that will be used for this location.

- Specify an ETL: Indicate the type of ETL that will process this location.

- Check “Active”

- Time Zone: Time zone used to encode data in the file

- Specify Landing Zone: The name of the Landing Zone (location)

- Indicate Data Type: Normally the interface type.

In the Alert tab:

-Check “Alert on Delay”

-Provide a Warning Threshold: Time when a Data Source will be considered late

-Provide an Error Threshold: Time when a Data Source will be considered missing.

In the Metadata tab

-Indicate the Host Name: Normally Location IP address.

In the Parameters tab

Source section

-Indicate the URL: Normally this will be a sftp address that indicates the landing zone and folder where the files to collect are located.

-Indicate User name: User Name to use to log-in into the landing zone

-Indicate Password: Password to use to log-in into the landing zone.

-Indicate Files newer than: Normally set it to 72

-Indicate Include file pattern: This normally will be part of the file name that is unique for all files of this type.

-Indicate Exclude file pattern: Normally will be *InProgress*

Destination section

-Indicate URL: This will be the local location where the file will be copy. Normally the location is unique for the Type of files collected and its location.

-Indicate File Pattern: Normally it will be as follow: %SOURCE_ID%.JDSU_IUPS.%FILE_TIME_YYYYMMDDHHMMSS%.5.%TOKEN(.,4)%.csv.gz

-Indicate Data Type: The type of interface.

Network section

-Indicate Connection Timeout: Normally 30000

-Indicate Read Timeout: Normally 120000

-Indicate Write Timeout: Normally 120000

Note: For most Locations, use the default value for any other parameters. Use an existing data source / location (of the same interface type) as a reference.