PURADIGM® ZONE™

User Manual

Introduction

Warnings

Warranty

Diagrams

Installations & Setup

Wall Mounting Setup & Installation

Base Stand Setup & Placement

Placement of Unit

Operations of Unit

Puradigm Technology Cell Replacement

Cleaning & Maintenance

Parts & Accessories

Specifications

Introduction

The PURADIGM® ZONETM is designed to provide years of trouble-free service when it is properly operated and maintained. This guide will help you through the steps to operate your machine.

Some parts of the unit will need to be replaced periodically. Replacement parts can be purchased from your authorized distributor or directly from www.PURADIGM.com.

Thank you for purchasing the PURADIGM® ZONETM.

Warnings

Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer.

Never insert hands into the unit’s fan motor while it is plugged in or running.

Avoid looking directly at the UV lamps in the PURADIGM Technology Cell.

Follow all installation instructions.

Before servicing or cleaning the unit, unplug from its power source.

Replace filter regularly to avoid damaging your unit.

WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG (GROUNDING) PLUG. PRODUCT WILL MALFUNCTION AND/OR CAUSE SHOCK IF NOT GROUNDED. THE PRODUCT SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE.

WARNING: THIS DEVICE PRODUCES POTENTIALLY HARMFUL UV LIGHT. DISCONNECT FROM POWER SUPPLY BEFORE SERVICING. FAILURE TO FOLLOW WARNINGS MAY CAUSE DAMAGE TO EYES AND SKIN.

WARNING: PRODUCTS PRODUCES OZONE IN THE AWAY MODE. NEVER USE AWAY MODE IN AN OCCUPIED SPACE. ENSURE THE SPACE IS FREE OF ANY HUMANS OR ANIMALS FOR AT LEAST 2 HOURS AFTER THE AWAY CYCLE HAS COMPLETED (AWAY CYCLE CAN BE SET FOR ½, 1, 2 or 4 HOURS)

Warranty

One Year Limited Warranty

LIMITED WARRANTY

Your PURADIGM® ZONETM (Product) is warranted to be free from all defects in material and workmanship in normal use for a period of 1 Year from date of purchase. Your PURADIGM Technology Cell’s Warranty is separate from your Product’s 1 Year Warranty.

The warranty is granted only to the original purchaser. The warranty is subject to the following provisions:

Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Product Owner’s Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized service or the use of other than authorized PURADIGM Parts are not covered.

PURADIGM, LLC. will, at its option, repair or replace a defective Product or part(s) for the Product that is/are covered by this warranty. As a matter of warranty policy, PURADIGM, LLC. will not refund the customer’s purchase.

CONSUMER INFORMATION

PURADIGM, LLC. declines all responsibility for all damages arising from improper use of the unit or in case of tampering with the unit.

Diagrams

Front of Unit

Back of Unit

Side of Unit

Remote Control

Installations & Setup

Begin by finding an open area to place your PURADIGM® ZONETM. Make sure it is near a power receptacle and is easily accessible for maintenance or cleaning.

NOTE: Ensure you remove the cover and then take off the Plastic Wrap that is on the filter prior to operation.

There are (2) options of installation

●  Option 1: Wall Mounting

●  Option 2: Base Stand

Wall Mounting Setup & Installation

The PURADIGM® ZONE™ is designed to also be a wall mountable unit.

The rear of the unit has 4 mounting screw holes designed for use with a standard VESA 300mm x 300mm wall mounting bracket. VESA wall mounting brackets are widely used for today’s flat screen TV’s and can normally be purchased in numerous locations where electronics and TV’s are sold.

Please follow the instructions included with your mounting bracket to insure a proper secure mounting for your PURADIGM® ZONE™.

See the section “Ideal Placement” before choosing the wall mounting location for your PURADIGM ZONE.

Base Stand Setup & Placement

Step One: Place the Base on the Bottom of the PURADIGM ZONE Unit.

Step Two: Insert the 4 screws provided into the bottom of the Base.


Step Three: Ensure the Base is properly secured by standing the unit onto the Base on a level surface.

Placement of Unit

There are several important factors to consider when selecting a location for your PURADIGM® ZONE™:

●  Place the unit where you can maximize the airflow such that the purification can fill the space adequately. Avoid areas where the airflow is exiting the targeted space. This will ensure that the purification produced by the PURADIGM® ZONE™ is optimally circulated.

●  Make sure the location you choose is as far away from the HVAC air return duct as possible.

●  Make sure the unit is not placed beside a window or door where the airflow might be directed out of the room.

●  Place the unit on top of something such that the unit will be at about half the height of the room. A shelf, a table or a mounting bracket is ideal.

●  To ensure the unit works properly, there should be as much open space as possible in front and to the sides of your PURADIGM® ZONE™ so that it can efficiently process the air in the area.

●  Never place an operating unit on the floor.

Use the following diagram as a guide for the placement of your Puradigm® ZONE™.

Operations of Unit

Once you have determined a proper location for your unit and calculated the area of the environment:

NOTE: Ensure you remove the cover and then take off the Plastic Wrap that is on the filter prior to operation.

The following is a basic outline of core operations for the PURADIGM® ZONE™ unit.

Step One: Insert the Power Plug into the wall outlet.

WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG (GROUNDING) PLUG. PRODUCT WILL MALFUNCTION AND/OR CAUSE SHOCK IF NOT GROUNDED. THE PRODUCT SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE.

Step Two: Turn the unit on by pressing the power button on the control panel located on the side of the unit or alternatively use the power button on the remote control.

Step Three: Adjusting the fan speed. The fan has 4 settings/speeds. Pressing the fan button on the control panel or remote will allow you to cycle through each speed.

Increasing the fan speed will provide more purification. Adjust the fan speed according to the contamination and size of the room.

Refresh Mode. Pressing the Refresh button on the control panel or remote control automatically sets the unit to the highest fan speed for a timed period and turns on the ozone plate

Setting 1 will run the Refresh Mode for (30) minutes.

Setting 2 will run the Refresh Mode for (1) hour.

Setting 3 will run the Refresh Mode for (2) hours.

Setting 4 will run the Refresh Mode for (4) hours.

WARNING: PRODUCTS PRODUCES OZONE IN THE AWAY MODE. NEVER USE AWAY MODE IN AN OCCUPIED SPACE. ENSURE THE SPACE IS FREE OF ANY HUMANS OR ANIMALS FOR AT LEAST 2 HOURS AFTER THE AWAY CYCLE HAS COMPLETED (AWAY CYCLE CAN BE SET FOR ½, 1, 2 or 4 HOURS)

Once the Refresh Mode cycle finishes running for the selected time. The unit will reset to the initial mode.

Puradigm Technology Cell Replacement

If you need to replace your PURADIGM Technology Cell (that is no longer under warranty) for any reason you will need to contact your dealer to purchase a new one. If your PURADIGM Technology Cell is having problems and is still under warranty, please contact your Distribution agent for maintenance or replacement options.

WARNING: THIS DEVICE PRODUCES POTENTIALLY HARMFUL UV LIGHT. DISCONNECT FROM POWER SUPPLY BEFORE SERVICING. FAILURE TO FOLLOW WARNINGS MAY CAUSE DAMAGE TO EYES AND SKIN.

Unplug your unit before replacing your PURADIGM Technology Cell. Gently remove the Power Cable from your old PURADIGM Technology Cell and plug it into your new one.

Once the power cable is installed, place the PURADIGM Technology Cell into its provided space above the fan. The PURADIGM Technology Cell should be placed with the warning label facing out to ensure proper airflow through the unit.

Install the Cover to secure the PURADIGM Technology Cell in place before plugging your unit in again.

Cleaning & Maintenance

Unplug your unit from the receptacle before any cleaning or maintenance is done.

Your PURADIGM® ZONETM filter should be replaced every 2-3 months depending on the quality of air in the establishment.

To clean your unit, use an Air Duster to first clear any debris inside the machine. If any remains, wipe it down with a damp cloth.

Step One: Remove the Cover Plate

Step Two: Remove the Screen in front of the Filter

Step Three: Remove the Filter

Step Four: Wipe down the inside of unit with soft moist cloth.

If your PURADIGM® ZONETM unit has any maintenance problems or requires replacements of parts you will need to contact PURADIGM.

Parts & Accessories

When talking to your dealer, retailer, or the manufacturer regarding replacement parts, please use the following parts number list below to reference the replacement parts.

IMAGE / PART NAME / SERIAL & PART NUMBER
PURADIGM® ZONE™ / ZN_IW_TR_1.0
COVER
BASE
SCREEN
FILTER (options)
PURADIGM® TECHNOLOGY CELL / PG1_3H_275-2W-SPL20
ION NEEDLES
POWER CORD

Specifications

Product Details

SKU: ZN_IW_TR_1.0

Weight (Not including Accessories): 6 kg (13.2 lbs)

Electrical Input: 120VAC 60Hz

Rated Power: 45W

Dimensions (HxLxD):(without base): 547 x 383 x 166 mm (21.5” x 15.1” x 6.5”)

Dimensions (HxLxD):(with base): 601 x 383 x 180 mm (23.7” x 15.1” x 7.1”)

Active Purification: Kansas State University tested on bacteria and pathogens

Advanced Filtration: 99.5% efficient for airborne particles of 0.3 micrometers

High Tech Ionization: Negative ion production of 1 million/cm3 approximately (at 500 mm from grill)

Modular Purifier: Equipped with a high quality ozone plate, maximum production 200mg/hr approximately

Puradigm Technology Cell

SKU: PG1-H3-275-2W-SPL20

Estimated Area Coverage

CADR Rating 153 m3/h (90 cfm)

Passive Area Coverage 13 m2 (135 sq/ft)

Active Area Coverage* 163 m2 (1750 sq/ft)

*Area coverage is an approximation and is based on proper placement of unit, adequate airflow and air circulation in the space and normal contamination levels. Area coverage is based on 2.4 m (8 ft) ceiling.

Warranty: 1 Year

Protected Under Patent:

US8585979B2 and WO 2012/033818A1

Visit our website for more information www.PURADIGM.com

© 2014 PURADIGM 2