2018 Asphalt MixtureHveemDesign Proficiency Samples 69 and 70

Data Sheet

Closing Date: July 26th, 2018

We encourage you to use the online data entry system. Or, you may fax 240-436-4899 or mail your data sheet to: John J. Malusky, AASHTO re:source 4441 Buckeystown Pike, Suite A, Frederick, MD 21704. If your laboratory is not registered to enter your results online, or if there are questions, contact AASHTO re:source at or call 240-436-4900.

HveemStabilometer (T246 / D1560) when using California Kneading Compactor (T247 or D1561)

Maximum Specific Gravity (T209/D2041):
Mark the Box at the Right to Show the Method Used – AASHTO T209 , ASTM D2041
For informational purposes only:
Type of Vacuum Measuring Device
Mercury Manometer , Absolute Pressure Gage (non-mercury)
Method of Agitation: Mechanical , Manual ; If Mechanical, Orbital , Vibratory
Vibration Frequency (or setting) if speed is adjustable? ______
Manufacturer ______and Model ______ / Sample 69 (A) / Sample 70 (B)
Maximum Specific Gravity, Gmm (nearest 0.001)...... (1)
HveemStabilometer Value (T246/D1560)-Using California Kneading Compactor
Mark the Box for the Method Used – AASHTO T246 , ASTM D1560 , Other
Specimen Height (nearest 0.01 in.) ...... (2)
Stabilometer Value Uncorrected (nearest unit) ...... (3)
Stabilometer Value Corrected (nearest unit)...... (4)
Bulk Specific Gravity (T166/D2726 or T331/D6752):
Mark the Box to Show the Method Used:
Method Using Saturated Surface-Dry Specimens: AASHTO T166 or ASTM D2726
Automatic Vacuum Sealing Method: AASHTO T331 or ASTM D6752
Bulk Specific Gravity, Gmb (nearest 0.001)...... (5)
Air Voids (T269/D3203):
Mark the Box at the Right to Show the Method Used – AASHTO T269 , ASTM D3203
Percent Air Voids (nearest 0.01 %)...... (6)
Lab Name: / Lab Number:
City, State:
Country:
Tested By:
Lab Phone:
Please complete the information below to identify your laboratory.

Additional Comments:

Continued on followingpage for Texas Gyratory Compactor (Tex-206-F)

HveemStabilometer (Tex-208-F) when using Tex-206-F Texas Gyratory Compactor

Maximum Specific Gravity (T209/D2041):
Mark the Box at the Right to Show the Method Used – AASHTO T209 , ASTM D2041
For informational purposes only:
Type of Vacuum Measuring Device
Mercury Manometer , Absolute Pressure Gage (non-mercury)
Method of Agitation: Mechanical , Manual ; If Mechanical, Orbital , Vibratory
Vibration Frequency (or setting) if speed is adjustable? ______
Manufacturer ______and Model ______ / Sample 69 (A) / Sample 70 (B)
Maximum Specific Gravity, Gmm (nearest 0.001)...... (7)
Bulk Specific Gravity (T166/D2726 or T331/D6752):
Mark the Box to Show the Method Used:
Method Using Saturated Surface-Dry Specimens: AASHTO T166 or ASTM D2726
Automatic Vacuum Sealing Method: AASHTO T331 or ASTM D6752
Bulk Specific Gravity, Gmb (nearest 0.001)...... (8)
Specimen Height (Tex 206-F) Height After Compaction
Specimen Height (nearest 0.01 in.) ...... (9)
HveemStabilometer Value (Tex-208-F)-Using Texas Gyratory Compactor
Mark the Box at the Right to Show the Method Used – ASTM D1560 Tex-208-F
Stabilometer Value - Do Not Apply Any Correction (nearest unit)...... (10)
Air Voids (T269/D3203):
Mark the Box at the Right to Show the Method Used – AASHTO T269 , ASTM D3203
Percent Air Voids (nearest 0.01 %)...... (11)
Please complete the information below to identify your laboratory.
Lab Name: / Lab Number:
City, State:
Country:
Tested By:
Lab Phone:
Additional Comments:

Continued onfollowing page for Superpave Gyratory Compactor using 100-mm Diameter Specimens (CP-L 5115)

HveemStabilometer (CP-L 5106) when using CP-L 5115 Superpave Gyratory Compactor and 100-mm Diameter Specimens

Maximum Specific Gravity (T209/D2041):
Mark the Box at the Right to Show the Method Used – AASHTO T209 , ASTM D2041
For informational purposes only:
Type of Vacuum Measuring Device
Mercury Manometer , Absolute Pressure Gage (non-mercury)
Method of Agitation: Mechanical , Manual ; If Mechanical, Orbital, Vibratory
Vibration Frequency (or setting) if speed is adjustable? ______
Manufacturer ______and Model ______ / Sample 69 (A) / Sample 70 (B)
Maximum Specific Gravity, Gmm (nearest 0.001)...... (12)
Bulk Specific Gravity (T166/D2726 or T331/D6752):
Mark the Box to Show the Method Used:
Method Using Saturated Surface-Dry Specimens: AASHTO T166 or ASTM D2726
Automatic Vacuum Sealing Method: AASHTO T331 or ASTM D6752
Bulk Specific Gravity, Gmb (nearest 0.001)...... (13)
Specimen Height (CP-L 5115) Height After Compaction
Specimen Height (nearest 0.1 mm) ...... (14)
HveemStabilometer Value (CP-L 5106)-Using Superpave Compactor
Mark the Box for the Method Used – AASHTO T246 ASTM D1560 CP-L 5106
Stabilometer Value Uncorrected (nearest unit) ...... (15)
Stabilometer Value Corrected (nearest unit)...... (16)
Air Voids (T269/D3203):
Mark the Box at the Right to Show the Method Used – AASHTO T269 , ASTM D3203
Percent Air Voids (nearest 0.01 %)...... (17)
Please complete the information below to identify your laboratory.
Lab Name: / Lab Number:
City, State:
Country:
Tested By:
Lab Phone: