There are four basic types of ground loop systems. Three of these—horizontal, vertical, and pond/lake—are closed-loop systems. The fourth type of system is the open-loop option. Which one of these is best depends on the climate, soil conditions, available land, and local installation costs at the site. All of these approaches can be used for residential and commercial building applications.

Closed-Loop Systems

Horizontal

This type of installation is generally most cost-effective for residential installations, particularly for new construction where sufficient land is available. It requires trenches at least four feet deep. The most common layouts either use two pipes, one buried at six feet, and the other at four feet, or two pipes placed side-by-side at five feet in the ground in a two-foot wide trench. The Slinky™ method of looping pipe allows more pipe in a shorter trench, which cuts down on installation costs and makes horizontal installation possible in areas it would not be with conventional horizontal applications.

Illustration of a horizontal closed loop system shows the tubing leaving the house and entering the ground then branching into three rows in the ground with each row consisting of six overlapping vertical loops of tubing At the end of the rows the tubes are routed back to the start of the rows and combined into one tube that runs back to the house

Vertical

Large commercial buildings and schools often use vertical systems because the land area required for horizontal loops would be prohibitive. Vertical loops are also used where the soil is too shallow for trenching, and they minimize the disturbance to existing landscaping. For a vertical system, holes (approximately four inches in diameter) are drilled about 20 feet apart and 100–400 feet deep. Into these holes go two pipes that are connected at the bottom with a U-bend to form a loop. The vertical loops are connected with horizontal pipe (i.e., manifold), placed in trenches, and connected to the heat pump in the building.

Illustration of a vertical closed loop system shows the tubing leaving a building and entering the ground then branching off into four rows in the ground In each row the tubing stays horizontal except for departing on three deep vertical loops At the end of the row the tubing loops back to the start of the row and combines into one tube that runs back to the building

Pond/Lake

If the site has an adequate water body, this may be the lowest cost option. A supply line pipe is run underground from the building to the water and coiled into circles at least eight feet under the surface to prevent freezing. The coils should only be placed in a water source that meets minimum volume, depth, and quality criteria.

Illustration of a pond or lake closed loop system shows the tubing leaving the house and entering the ground then extending to a pond or lake The tubing drops deep into the pond or lake and then loops horizontally in seven large overlapping loops then returns to the water s edge extends up near the surface and returns back to the house

Open-Loop System

This type of system uses well or surface body water as the heat exchange fluid that circulates directly through the GHP system. Once it has circulated through the system, the water returns to the ground through the well, a recharge well, or surface discharge. This option is obviously practical only where there is an adequate supply of relatively clean water, and all local codes and regulations regarding groundwater discharge are met.

Illustration of an open loop system shows a tube carrying water out of the house into the ground and over to a well where it discharges into the groundwater A separate tube in a well some distance away draws water from the well and returns it to the house

Geothermal Heat Pumps

Two 36-ton geothermal heat pumps used at the College of Southern Idaho.

The geothermal heat pump, also known as the ground source heat pump, is a highly efficient renewable energy technology that is gaining wide acceptance for both residential and commercial buildings. Geothermal heat pumps are used for space heating and cooling, as well as water heating. Its great advantage is that it works by concentrating naturally existing heat, rather than by producing heat through combustion of fossil fuels.

The technology relies on the fact that the Earth (beneath the surface) remains at a relatively constant temperature throughout the year, warmer than the air above it during the winter and cooler in the summer, very much like a cave. The geothermal heat pump takes advantage of this by transferring heat stored in the Earth or in ground water into a building during the winter, and transferring it out of the building and back into the ground during the summer. The ground, in other words, acts as a heat source in winter and a heat sink in summer.

The system includes three principal components:

  • Geothermal earth connection subsystem
  • Geothermal heat pump subsystem
  • Geothermal heat distribution subsystem.

Earth Connection

Using the Earth as a heat source/sink, a series of pipes, commonly called a "loop," is buried in the ground near the building to be conditioned. The loop can be buried either vertically or horizontally. It circulates a fluid (water, or a mixture of water and antifreeze) that absorbs heat from, or relinquishes heat to, the surrounding soil, depending on whether the ambient air is colder or warmer than the soil.

Heat Pump Subsystem

For heating, a geothermal heat pump removes the heat from the fluid in the Earth connection, concentrates it, and then transfers it to the building. For cooling, the process is reversed.

Heat Distribution Subsystem

Conventional ductwork is generally used to distribute heated or cooled air from the geothermal heat pump throughout the building.

Residential Hot Water

In addition to space conditioning, geothermal heat pumps can be used to provide domestic hot water when the system is operating. Many residential systems are now equipped with desuperheaters that transfer excess heat from the geothermal heat pump's compressor to the house's hot water tank. A desuperheater provides no hot water during the spring and fall when the geothermal heat pump system is not operating; however, because the geothermal heat pump is so much more efficient than other means of water heating, manufacturers are beginning to offer "full demand" systems that use a separate heat exchanger to meet all of a household's hot water needs. These units cost-effectively provide hot water as quickly as any competing system.

Additional Information

For more specifics on geothermal heat pump systems, including types, benefits and selection and installation, visit these pages on the DOE Consumer's Guide Web site:

  • Types of Geothermal Heat Pump Systems
  • Benefits of Geothermal Heat Pump Systems
  • Selecting and Installing a Geothermal Heat Pump System

To lean more about geothermal heat pumps, visit the International Ground Source Heat Pump Association, where you can search for local IGSHPA Accredited Installers, Trainers, and Certified Designers using their Business Directory. Information is also available from the Geothermal Heat Pump Consortium, which can help you can find a knowledgeable contractor in your area by using their GeoExchange Industry Directory.

While primarily intended for the energy managers of Federal facilities, DOE's Federal Energy Management Program does have information on purchasing and installing geothermal heat pumps that would be of help to commercial building owners or contractors on their heat pump Web page.

Selecting and Installing a Geothermal Heat Pump System

Heating and Cooling Efficiency of Geothermal Heat Pumps

The heating efficiency of ground-source and water-source heat pumps is indicated by their coefficient of performance (COP), which is the ratio of heat provided in Btu per Btu of energy input. Their cooling efficiency is indicated by the Energy Efficiency Ratio (EER), which is the ratio of the heat removed (in Btu per hour) to the electricity required (in watts) to run the unit. Look for the ENERGY STAR® label, which indicates a heating COP of 2.8 or greater and an EER of 13 or greater.

Manufacturers of high-efficiency geothermal heat pumps voluntarily use the EPA ENERGY STAR label on qualifying equipment and related product literature. If you are purchasing a geothermal heat pump and uncertain whether it meets ENERGY STAR qualifications, ask for an efficiency rating of at least 2.8 COP or 13 EER.

Many geothermal heat pump systems carry the U.S. Department of Energy (DOE) and EPA ENERGY STAR label. Ask your contractor about special financing or incentives for purchasing energy efficient products, including ENERGY STAR qualified products.

Economics of Geothermal Heat Pumps

Geothermal heat pumps save money in operating and maintenance costs. While the initial purchase price of a residential GHP system is often higher than that of a comparable gas-fired furnace and central air-conditioning system, it is more efficient, thereby saving money every month. For further savings, GHPs equipped with a device called a "desuperheater" can heat the household water. In the summer cooling period, the heat that is taken from the house is used to heat the water for free. In the winter, water heating costs are reduced by about half.

Although initially more expensive to install than conventional systems, properly sized and installed GHPs deliver more energy per unit consumed than conventional systems.

And since geothermal heat pumps are generally more efficient, they are less expensive to operate and maintain — typical annual energy savings range from 30% to 60%. Depending on factors such as climate, soil conditions, the system features you choose, and available financing and incentives, you may even recoup your initial investment in two to ten years through lower utility bills.

But when included in a mortgage, your GHP will have a positive cash flow from the beginning. For example, say that the extra $3,500 will add $30 per month to each mortgage payment. The energy cost savings will easily exceed that added mortgage amount over the course of each year.

On a retrofit, the GHP's high efficiency typically means much lower utility bills, allowing the investment to be recouped in two to ten years. It may also be possible to include the purchase of a GHP system in an "energy-efficient mortgage" that would cover this and other energy-saving improvements to the home. Banks and mortgage companies can provide more information on these loans.

There may be a number of special financing options and incentives available to help offset the cost of adding a geothermal heat pump (GHP) to your home. These provisions are available from federal, state, and local governments; power providers; and banks or mortgage companies that offer energy-efficient mortgage loans for energy-saving home improvements. Be sure the system you're interested in qualifies for available incentives before you make your final purchase.

To find out more about financing and incentives that are available to you, visit the Database of State Incentives for Renewable Energy (DSIRE) Web site. The site is frequently updated with the latest incentives. You should also check with your electric utility and ask if they offer any rebates, financing, or special electric rate programs.

Evaluating Your Site for a Geothermal Heat Pump

Because shallow ground temperatures are relatively constant throughout the United States, geothermal heat pumps (GHPs) can be effectively used almost anywhere. However, the specific geological, hydrological, and spatial characteristics of your land will help your local system supplier/installer determine the best type of ground loop for your site:

Geology

Factors such as the composition and properties of your soil and rock (which can affect heat transfer rates) require consideration when designing a ground loop. For example, soil with good heat transfer properties requires less piping to gather a certain amount of heat than soil with poor heat transfer properties. The amount of soil available contributes to system design as well — system suppliers in areas with extensive hard rock or soil too shallow to trench may install vertical ground loops instead of horizontal loops.

Hydrology

Ground or surface water availability also plays a part in deciding what type of ground loop to use. Depending on factors such as depth, volume, and water quality, bodies of surface water can be used as a source of water for an open-loop system, or as a repository for coils of piping in a closed-loop system. Ground water can also be used as a source for open-loop systems, provided the water quality is suitable and all ground water discharge regulations are met.

Before you purchase an open-loop system, you will want to be sure your system supplier/installer has fully investigated your site's hydrology, so you can avoid potential problems such as aquifer depletion and groundwater contamination. Antifreeze fluids circulated through closed-loop systems generally pose little to no environmental hazard.

Land Availability

The amount and layout of your land, your landscaping, and the location of underground utilities or sprinkler systems also contribute to your system design. Horizontal ground loops (generally the most economical) are typically used for newly constructed buildings with sufficient land. Vertical installations or more compact horizontal "Slinky™" installations are often used for existing buildings because they minimize the disturbance to the landscape.

Installing Geothermal Heat Pumps

Because of the technical knowledge and equipment needed to properly install the piping, a GHP system installation is not a do-it-yourself project. To find a qualified installer, call your local utility company, the International Ground Source Heat Pump Association or the Geothermal Heat Pump Consortium for their listing of qualified installers in your area. Installers should be certified and experienced. Ask for references, especially for owners of systems that are several years old, and check them.

The ground heat exchanger in a GHP system is made up of a closed or open loop pipe system. Most common is the closed loop, in which high density polyethylene pipe is buried horizontally at 4-6 feet deep or vertically at 100 to 400 feet deep. These pipes are filled with an environmentally friendly antifreeze/water solution that acts as a heat exchanger. In the winter, the fluid in the pipes extracts heat from the earth and carries it into the building. In the summer, the system reverses and takes heat from the building and deposits it to the cooler ground.

The air delivery ductwork distributes the heated or cooled air through the house's duct work, just like conventional systems. The box that contains the indoor coil and fan is sometimes called the air handler because it moves house air through the heat pump for heating or cooling. The air handler contains a large blower and a filter just like conventional air conditioners.

Most geothermal heat pumps are automatically covered under your homeowner's insurance policy. Contact your insurance provider to find out what its policy is. Even if your provider will cover your system, it is best to inform them in writing that you own a new system.