TRANSMISSION POWER SHIFT 10/06/2009 10:23:31 AM

WO: 645610 Increase in PQ and Fe. Significant increase in ISO code.

Please carry out a filter and screen inspection.

Capture all findings on this sheet.

Give filter media to Gideon. Capture wo numb on media/bag.

------

CURRENT SAMPLE
Customer / HWE_MINING_YANDI / Serial No / 2BW00606
Unit No / DT4049 / Model / 789C
Make / Caterpillar / Oil Type / CASTROL TFC430
Oil Grade / 30 / Compartment / TRANSMISSION POWER SHIFT
Job No / Meter / 30861
Lab No / 391561507 / Sample Date / 30/05/2009
Eval / C / Location
DETAILS
Lab No / Eval / Date Sampled / Date Received / Meter Read / Fluid Hours / Fluid Added / Fluid Changed
391561507 / C / 30/05/2009 / 5/06/2009 / 30861 / 452 / 0.00 / N
391462530 / B / 17/05/2009 / 26/05/2009 / 30630 / 221 / 0.00 / N
391271511 / B / 30/04/2009 / 7/05/2009 / 30409 / 984 / 0.00 / Y
390921606 / B / 27/03/2009 / 2/04/2009 / 29991 / 566 / 0.00 / N
ELEMENT TESTS
Lab No / Eval / PQI / Fe / Cu / Cr / Pb / Sn / Ni / Al / Si / Na / K / Mo / B / Ba / Mg / Ca / Zn / P / Ag / Mn / V / Ti / Cd
391561507 / C / 26 / 5 / 1 / 0 / 0 / 0 / 0 / 0 / 6 / 1 / 0 / 1 / 3 / 0 / 22 / 3594 / 988 / 827 / 1 / 0 / 0 / 0 / 0
391462530 / B / 0 / 2 / 0 / 0 / 0 / 0 / 0 / 0 / 5 / 2 / 1 / 1 / 2 / 0 / 25 / 4092 / 1105 / 949 / 1 / 0 / 0 / 0 / 0
391271511 / B / 0 / 4 / 2 / 0 / 0 / 0 / 0 / 0 / 5 / 1 / 0 / 1 / 3 / 0 / 22 / 3923 / 1051 / 887 / 0 / 0 / 0 / 0 / 0
390921606 / B / 2 / 2 / 3 / 0 / 0 / 0 / 0 / 0 / 5 / 2 / 1 / 1 / 2 / 0 / 21 / 3880 / 1032 / 876 / 1 / 0 / 0 / 0 / 0
LUBRICANT TESTS
Lab No / Eval / W / H2O / V40 / TBN / TAN / ST / OXI / NIT / SUL / ISO5 / ISO15 / 5µ / 10µ / 15µ / 20µ / 25µ / 50µ / 100µ
391561507 / C / N / 0.0 / 98.4 / 3 / 6 / 5 / 22 / 20 / 28207 / 16078 / 8758 / 5178 / 3177 / 118 / 3
391462530 / B / N / 0.0 / 98.9 / 2 / 3 / 2 / 17 / 14 / 1128 / 294 / 119 / 58 / 31 / 2 / 0
391271511 / B / N / 0.0 / 97.7 / 2 / 9 / 4 / 15 / 12 / 304 / 58 / 34 / 26 / 20 / 9 / 3
390921606 / B / N / 0.0 / 92.6 / 10 / 1 / 3 / 19 / 15 / 3160 / 746 / 296 / 125 / 57 / 9 / 3
COMMENTS
Lab No / Eval / Comment
391561507 / C / Oil add pack suggests incorrect or mixed oils.The PQ index is slightly high.The ISO oil cleanliness code ranges >5 and >15 micron arehigh.Foreign particles are visible in this sample bottle Check filter media and screen for wear particles and contaminants.Before extraction ensure the sample area is clean. To remove harmful contaminants from this oil.Fit high efficiency oil filters for a maximum time of 250 hours.For enquiries regarding this evaluation, please contact Jim Durning Ph 08 9377 9757. Sample Note :
391462530 / B / Oil add pack suggests incorrect or mixed oils.All other test results appear normal. Continue to sample at consistent intervals.For enquiries regarding this evaluation, please contact Ross Gilmore Ph 08 9377 9506. Sample Note :
391271511 / B / Oil add pack suggests incorrect or mixed oils.All other test results appear normal. Continue to sample at consistent intervals. For enquiries regarding this evaluation, please contact Jim Durning Ph 9377 9757 Sample Note :
390921606 / B / The ISO oil cleanliness code range >5 micron is slightly high.Check filter medium and screens for wear material and contamination.All other test results appear normal. For enquiries regarding this evaluation, please contact Ross Gilmore Ph 08 9377 9506. Sample Note :