Tables for SPKIR Instruments

Tables for SPKIR Instruments

Tables for SPKIR Instruments

This attachment contains Microsoft Word versions of the tables found in SectionL.7.

Fill out Tables L-5 and L-6 with specifications of your proposed Downwelling Spectral Irradiance instruments and include them in the Technical Volume of your proposal. SectionL.7.1.2.1 provides detailed instructions for filling out these tables.

Table L-5

Downwelling Spectral Irradiance (SPKIR) Instrument Compliance Matrix
WithInstrument Specifications in Attachment J-3

Instrument Spec I.D. / Parameter / Units / Parameter Value by SPKIR Series / Substantiation
A / B
SPKI-001 / Minimum value / μmol photons
m-2 s-1
SPKI-002 / Maximum value / μmol photons
m-2 s-1
SPKI-003 / Accuracy / %
SPKI-004 / Precision / μmol photons
m-2 s-1
SPKI-005 / Sampling frequency / Hz
SPKI-006 (threshold)
SPKI-007
(objective) / Wavelength range / nm to nm
SPKI-008 / Number of bands / # of bands
SPKI-009 / Spectral bandwidth / nm
Appendix / Operational Depth Range / m
Appendix / Survivable Depth / m
Appendix / Life of internal battery / months / N/A
Appendix / Internal Data Storage / # of samples / N/A

Table L-6

Downwelling Spectral Irradiance (SPKIR) Instrument Compliance Matrix
With Common Specifications in Attachment J-1

Common Spec I.D. / Parameter / Units / Parameter Value by SPKIR Series / Substantiation
A / B
OPER-001 / Salinity range / PSS
OPER-002 / Temperature range / oC
OPER-003 / Biofouling mitigation measures provided? / Yes/No
OPER-004
(objective) / Biofouling mitigation provides specified accuracy for defined deployment intervals? / Yes/No
OPER-005 (objective) / Maintains calibration within specified accuracy for defined deployment intervals? / Yes/No
OPER-006 / Meets all performance requirements for defined deployment intervals without need for physical maintenance? / Yes/No
OPER-007 / Deployed, recovered, redeployed without performance impairment? / Yes/No
MECH-001 / Instrument housing / Materials used / N/A
MECH-002 / Instrument connector / Materials used / N/A
MECH-006 (objective) / Anodized contact surfaces? / Yes/No / N/A
MECH-003
MECH-004
MECH-005 / Electronic housings immersion depth / m
ELEC-001
(objective) / Capable of operating in a +/- 50 VDC potential? / Yes/No
(if no, voltage)
ELEC-002
(objective) / Grounding with no connection to seawater? / Yes/No
ELEC-003 / Battery Life / Months / N/A
ELEC-004 / Returns to defined state upon being depowered and repowered? / Yes/No
ELEC-005 (threshold)
ELEC-006 (objective) / Isolation from seawater / mega ohms
DATA-001 / Provides internal data storage? / Yes/No / N/A / N/A
INTF-001 / Powered by two wire floating voltages? / Yes/No / N/A
INTF-002 / Supply voltage / Volts DC / N/A
INTF-003 / Time Stamping / List the supported capabilities / N/A
INTF-004 (objective) / Internal clock? / Yes/No / N/A
INTF-005 / Synchronize/set clock over the interface? / Yes/No / N/A
INTF-006 / Data rate if over serial interface / bits/sec / N/A
INTF-007
(objective) / User settable data rate over serial interface? / Yes/No
If yes, maximum serial rate / N/A
INTF-008 (objective) / Ethernet interface? / Yes/No
If yes, list the auto-discovery mechanism(s) / N/A
INTF-009 / ACKs command execution including succeed/fail? / Yes/No / N/A
INTF-010 / Communications interface(s) / List the interfaces / N/A
INTF-011 / Remote control and access? / Yes/No / N/A
INTF-012 (objective) / Supports remote firmware installation? / Yes/No / N/A
INTF-013 / All data accessible remotely via communications interface? / Yes/No / N/A
INTF-014 (objective) / Supports polled operation? / Yes/No / N/A
Supports asynchronous mode operation? / Yes/No / N/A
INTF-015 / Communicate via inductive modem? / Yes/No / N/A / N/A / N/A
COMP-001 / Standards compatibility / List the standards
SAFE-001 / Protection of personnel / List protections provided
SAFE-002 / Hazards labeled? / Yes/No / N/A
SAFE-003 / Use of radioactive isotopes? / Yes/No
(if yes, identify which ones)
SHIP-001 / Containers meet ASTM D4169 Level1? / Yes/No
SHIP-002 / Stored without degradation between -20 and 50°C for 12 months? / Yes/No
(if no, provide limitations)
SHIP-003 / External cases labeled with safe handling precautions? / Yes/No / N/A
IDEN-001 / Indelible vendor marking on external surface? / Yes/No / N/A
IDEN-002 / Capable of OOI marking without damage? / Yes/No / N/A
QUAL-001 / Materials used and treated reduce wear, corrosion, and deterioration to allow multiple deployments? / Yes/No

Fill out Table L-7 with the models of your proposed Downwelling Spectral Irradiance instruments and include the table in the Technical Volume of your proposal. SectionL.7.1.2.1 provides detailed instructions for filling out this table.

Table L-7

Proposed Models for Downwelling Spectral Irradiance(SPKIR) Instruments

SPKIRSeries / Contractor Instrument Model Number or Designation
A
B

Fill out Table L-8 and include it in the Past Performance Volume of your proposal. SectionL.7.1.3 provides detailed instructions for filling out this table.

Table L-8.

Past Performance for Each Contract

Effort name
Company Performing the Effort
Contract name
Period of performance / From DD/MM/YYYY to DD/MM/YYYY
Contract value in $
Customer name and address
Technical Point of contact information
(name, phone number, e-mail)
Contractual Point of contact information
(name, phone number, e-mail)
(extend as necessary)

Ver 0-01Page 1 of 5