Table S1 Effects of ratio of biotin to anti-Butocarboxim MAb (n=3)
Concentrationa / IC50(ng·mL-1) / Negative (Amax) / Amax/IC5010* / 362 / 1.09 / 3.02
20* / 295 / 1.03 / 3.48
40* / 414 / 1.22 / 2.95
60* / 502 / 1.16 / 2.3
100* / 432 / 1.04 / 2.4
a Biotin with ratio of molar excess against anti-Butocarboxim MAb concentration.
Figure S1 Effects of pH on bi-ELISA. The ratio of signals (OD value for bi-ELISA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ELISA, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are pH values of the solution (n = 3)
Figure S2 Effects of ionic strengths on bi-ELISA. The ratio of signals (the ratio of OD value for bi-ELISA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ELISA, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are ionic strengths of the solution (n = 3)
Figure S3 Effects of dilution ratio of ABC on bi-ELISA. The ratio of signals (the ration of OD value for bi-ELISA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ELISA, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are dilution ratio of ABC of the solution (n = 3)
Figure S4 Effects of pH on bi-ECIA. The ratio of signals (the ration of SWV response for bi-ECIA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ECIA system, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are pH values of the solution (n = 3)
Figure S5 Effects of ionic strengths on bi-ECIA. The ratio of signals (the ration of SWV response for bi-ECIA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ECIA system, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are ionic strengths of the solution (n = 3)
Figure S6 Effects of dilution ratio of ABC on bi-ECIA. The ratio of signals (the ratio of SWV response for bi-ECIA in the absence and presence of Butocarboxim in sample) was chosen as the criteria to evaluate the bi-ECIA system, the concentration of Butocarboxim was 243 ng·mL-1. And the x axis values are dilution ratio of ABC of the solution (n = 3)