File Format Document

Shared Supply Meter Point Transfer of Ownership Notification Template (TRS)

Transporter to System User

Copyright Xoserve 2014©, all rights reserved.

No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / XOSERVE
Owner: / XOSERVE
Version: / 1.1
Status: / Approved
Date: / 10/09/2015

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
1.0 / 1154 / 13-MAR-2015 / 01-OCT-2015 / For Approval
1.1FA / 1154 / 09-Jun-2015 / TBC / For Approval
1.1A / 1154 / 10-Sept-2015 / Project Nexus Implementation Date / Approved
21 Different record types
Level / Record Name / Occurrence / Optionalityly
1 / A00_STANDARD_HEADER / 1 / M
1 / RT_S15_TRANSFER_OF_OWNERSHIP / 1 / O
2 / RT_S66_CONTACT_DETAILS / Up to 5 / M
3 / RT_S67_ELECTRONIC_DEVICE / Up to 4 / M
2 / RT_S70_ADDRESS / 1 / M
3 / RT_S75_METER_POINT_DETAILS / UP to 500 / M
4 / RT_S98_SMART_DATA / 1 / O
4 / RT_K12_MAM_GAO_DETAILS / 1 / O
4 / RT_K85_GENERIC_ORG_NOTIFICATION / Up to 15 / O
4 / RT_U71_NTS_OPTIONAL_RATE_DET / 1 / O
4 / RT_U73_LDZ_OPTIONAL_RATE_DET / 1 / O
4 / RT_U74_CSO_DET / 1 / O
4 / RT_U75_ASSET_CHARGES / Up to 1000 / O
4 / RT_U90_SSMP_CHARGES / Up to 15 / M
1 / RT_S08_LAPSED_CONFIRMATION_DETS / 1 / O
2 / RT_S70_ADDRESS / 1 / M
3 / RT_S76_LAPSED_CONF_SMP_DETAILS / 1 / M
2 / RT_S72_REJECTION_DETAIL / 1 / M
1 / RT_S88_CEASED_RESPONSIBLITY / 1 / O
2 / RT_K13_SMP_CEASED_OWN_DETS / 1 / M
1 / RT_S63_NTFN_OF_RETAINED_RESPONS / 1 / O
1 / TR_Z99_STANDARD_TRAILER / 1 / M

Note 1

OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places

Note 2

All text fields will be enclosed in double quotes ("")

HD_A00_STANDARD_HEADER

RECORD/FIELD_NAME *Occurs Max 1* / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / DEFINITION: A code identifying the type of request that this record represents.
VALUE:A00
ORGANISATION_ID / M / N / 10 / 0 / DEFINITION: A reference which uniquely identifies a User/Organisation.
FILE_TYPE / M / T / 3 / 0 / DEFINITION: An application specific code used to identify the structure and the usage of the file.
VALUE: TRS
CREATION_DATE / M / D / 8 / 0 / DEFINITION: The date on which the file was generated.
FORMAT: YYYYMMDD
CREATION_TIME / M / M / 6 / 0 / DEFINITION: The time at which the file was generated (within the Creation Date).
FORMAT: HHMMSS
GENERATION_NUMBER / M / N / 6 / 0 / DEFINITION: A sequence number which represents an issue of a file that is unique for a combination of System User and file type. Files of the same file type submitted by a System User or to a System User must have consecutive numbers
Total / 36

RT_S15_TRANSFER_OF_OWNERSHIP

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE : S15
SUPPLY_POINT_CONFIRMATION_REFERENCE / M / T / 10 / 0 / A sequential number that uniquely identifies the Confirmation.
NOMINATION_SHIPPER_REF / O / T / 30 / 0 / A reference supplied by the System User when making a Nomination. It may be used by the System User to identify the Nomination and any subsequent Confirmation made for that Nomination.
CONFIRMATION_EFFECTIVE_DATE / M / D / 8 / 0 / The date on which ownership of the Supply Meter Point is requested to commence.
FORMAT: YYYYMMDD.
MRF_TYPE_CODE / O / T / 1 / 0 / A code identifying a valid meter reading frequency. VALUES: D - Daily, M - Monthly, 6 - Six-monthly, A - Annually.
REQUESTED_DM_SOQ / O / N / 10 / 0 / The requested peak daily supply offtake quantity (SOQ) of a Supply Meter Point. CONTEXT: Mandatory for class 1 and 2 supply meter points and only applicable to class 1 and 2. The new daily rate of gas flow deemed to be required by the Customer in the future.
REQUESTED_DM_SHQ / O / N / 10 / 0 / The requested peak hourly supply offtake quantity (SHQ) of a Supply Meter Point. CONTEXT: Mandatory for class 1 and 2 supply meter points and only applicable to class 1 and 2. The new hourly rate of gas flow deemed to be required by the Customer in the future.
OFFERED_SMP_SOQ / O / N / 10 / 0 / The offered peak daily supply offtake quantity (SOQ) of a Supply Meter Point. CONTEXT: The maximum rate of gas flow that is allowable by the Transporters.
OFFERED_DM_SHQ / O / N / 10 / 0 / The offered peak hourly supply offtake quantity (SHQ) of a Supply Meter Point. CONTEXT: Only applicable to Class 1 and 2.CONTEXT: The maximum hourly rate of gas flow that is allowable by Transporters and on which this request will be accepted.
EXIT_CAPACITY_LDZ(ECN)_CHARGE_RATE / M / N / 10 / 4 / Exit Zone charges pence/peak kWh per day as described in the DN charging statements.
LDZ_CUSTOMER_CHARGE_RATE / M / N / 10 / 4 / A charge to cover costs of services such as meter reading, emergency cover, provision of meter and service pipe, etc.
LDZ_COMMODITY_CHARGE_RATE / M / N / 10 / 4 / The charge per unit of gas transported in a Local Distribution Zone (LDZ)
LDZ_CAPACITY_CHARGE_RATE / O / N / 10 / 4 / A charge for peak system use for firm Supply Meter Points
EXIT_ZONE_IDENTIFIER / M / T / 3 / 0 / A unique reference for the Exit Zone. CONTEXT: For iGT Supply Meter Points the Exit Zone will be based on the CSEP connection and not on the Supply Meter Point Post Code.
LDZ_IDENTIFIER / M / T / 4 / 0 / This field identifies the LDZ to which the Supply Meter Point is associated.
END_USER_CATEGORY / O / N / 10 / 0 / A unique reference for the End User Category.
SUPPLY_POINT_CATEGORY / M / T / 5 / 0 / The category of grouping for which gas is nominated for the Supply Meter Point. VALUES:
VLDMC-Very Large Daily Metered Consumer.
DMC-Daily Metered Consumer
NDMA-Non Daily Metered Aggregate
DMAF-Daily Metered Aggregate Firm.
SP_MANNED_24_HOURS_ INDICATOR / O / T / 1 / 0 / Detailswhethertheproposedsupplypointismanned24hours for the purposes of emergency contacts. If the supply point will be manned 24 hours then less actual contact details are required. VALUES: Y / N.
PREMISES_CUSTOMER_NAME / O / T / 40 / 0 / ThenameofthecustomerwhichtheShipperconsiderstobethe end consumer at the premises.
SHIPPERS_CUSTOMER_NAME / O / T / 40 / 0 / ThenameofthecustomerwithwhichtheShipperdealsinrelation to a Supply Meter Point. This is not always the consumer.
RECORDED_DATE / M / D / 8 / 0 / The date on which the original request was recorded on Transporter Systems. FORMAT: YYYYMMDD.
RECORDED_TIME / M / M / 6 / 0 / The time at which the original request was recorded on Transporter Systems. FORMAT: HHMMSS.
MARKET_SECTOR_CODE / O / T / 1 / 0 / DEFINITION: A code that specifies that the site is used for domestic or industrial and commercial purposes. VALUES : D – Domestic or I - Industrial
SUPPLY_METER_POINT_CLASS / O / N / 1 / 0 / It defines the class type for the Supply Meter Point. VALUES: 1 – Class 1, 2 – Class 2, 3 – Class 3, 4 - Class 4
METER_READ_BATCH_FREQUENCY / O / T / 1 / 0 / The frequency on which reads will be received for class 3 Supply Meter Points. VALUES: W- 7 days, F – 14 days, M – month.
CURRENT_YEAR_MINIMUM_SOQ / O / N / 10 / 0 / Minimum bookable daily capacity based on the historic maximum daily offtake for a Supply Meter Point in the current gas year. CONTEXT: This is applicable for Class 1 and Class 2 sites only.
LAST_RECORDED_READ / O / T / 12 / 0 / The last recorded read of the supply meter point.
LAST_RECORDED_READ_DATE / O / D / 8 / 0 / Date of last recorded read.
FORMAT: YYYYMMDD
SEASONAL_LSP_INDICATOR / O / T / 1 / 0 / Indicates whether the Supply Meter Point is a Seasonal LSP.
VALUES: Y or Blank
SEASONAL_LSP_PERIOD_START_MONTH / O / N / 2 / 0 / The last month in a year that offtake is permissible at the Seasonal LSP. VALUES: 4 (April) to 9 (September)
SEASONAL_LSP_PERIOD_END_MONTH / O / N / 2 / 0 / The last month in a year that offtake is permissible at the Seasonal LSP. VALUES: 4 (April) to 9 (September)
FORMULA_YEAR_SMP_SOQ / O / N / 10 / 0 / The SOQ of the Supply Meter Point that is fixed throughout the formula year for determination of transportation rates for Class 3 and Class 4.
GAS_NOMINATION_ID / O / T / 10 / 0 / Gemini system identifier that should be used to nominate gas for the supply meter point.
PRIORITY_CONSUMER_CATEGORY / O / T / 1 / 0 / The category of priority consumer at the Supply Meter Point.
VALUES: A - Category A – Organisations providing a relevant vital social need for example; Institutions providing care for those to be at risk through age, sickness or infirmity e.g. hospitals, convalescent and nursing homes, homes for the elderly or disabled.
or
C - Category C - Consumers without an alternative fuel source, who if they ceased offtake in the timescales required, would risk damage to essential plant with a replacement value exceeding £50 million.
Total / 308

RT_S66_CONTACT_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record presents.
VALUE: S66
CONTACT_TYPE / M / T / 3 / 0 / A code which describes the type of contact.
VALUES : EMR - Emergency, ISO -Isolation
(Organisation), ISC – Isolation
(Person or Role), CON – Consumer
CONTACT_TITLE / O / T / 6 / 0 / Title of contact e.g. Mr, Miss, Sir, Doctor, etc.
M – Mandatory where
CONTACT_TYPE = EMR and JOB_TITLE not given
CONTACT_SURNAME / O / T / 30 / 0 / The surname of the contact.
M – Mandatory where
CONTACT_TYPE = CON and site is domestic.
M – Mandatory where
CONTACT_TYPE = EMR and JOB_TITLE not given
CONTACT_INITIALS / O / T / 4 / 0 / Initials of the contact.
M – Mandatory where
CONTACT_TYPE = CON and site
is domestic.
O – Optional where
CONTACT_TYPE = EMR
CONTACT_FIRST_NAME / O / T / 15 / 0 / First Name of the contact.
CONTACT_JOB_TITLE / O / T / 30 / 0 / Contacts Job Title.
M – Mandatory if BOTH
CONTACT_SURNAME and
CONTACT_TITLE not provided
where CONTACT_TYPE = EMR.
CONTACT_EFFECTIVE_DATE / M / D / 8 / 0 / Effective date from when the contact is valid
Total / 99

RT_S67_ELECTRONIC_DEVICE

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE: S67
CONT_ELECTRONIC_COMM_TYPE / M / T / 3 / 0 / A code which classifies the electronic address type.
VALUES: FAX - Fax, PAG – Pager
Number TEL - Telephone, “PAG” or “FAX”
can only be provided if in conjunction with “TEL” (i.e. if
“TEL” is also provided), etc
CONTACT_ELECTRONIC_ADDRESS / M / T / 241 / 0 / Electronic address such as telephone number etc
Total / 247

RT_S70_ADDRESS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S70
BUILDING_NUMBER / O / N / 4 / 0 / Building Number as defined in PAF.
SUB_BUILDING_NAME / O / T / 30 / 0 / Sub Building Name as defined in PAF.
BUILDING_NAME / O / T / 50 / 0 / Building Name as defined in PAF.
PRINCIPAL_STREET / O / T / 40 / 0 / A combination THOROUGHFARE NAME and THOROUGHFARE DESCRIPTOR as defined in PAF.
DEPENDENT_LOCALITY / O / T / 40 / 0 / A named, geographically defined area within a POST TOWN area (a Postal District).CONTEXT: Dependant Locality as defined in PAF.
POST_TOWN / O / T / 40 / 0 / The post town is the location where the street lies.
POSTCODE_OUTCODE / M / T / 4 / 0 / Standard PAF outcode as defined in the PAF digest.
POSTCODE_INCODE / M / T / 4 / 0 / Standard PAF incode as defined in the PAF digest.
Total / 215

RT_S75_METER_POINT_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S75
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
METER_LOCATION_CODE / M / N / 2 / 0 / DEFINITION: A code representing the location of a meter.
VALUES: 00 -Unknown,
1 -Cellar,
2 -Under Stairs,
3 -Hall,
4 -Kitchen,
5 -Bathroom,
6 -Garage,
7 -Canteen
8 -Cloakroom,
9 -Cupboard,
10 -Domestic Science
11 -Front Door,
12 -Hall Cupboard
13 -Kitchen Cupboard
14 -Kitchen Under Sink
18 -Outside WC,
19 -Pantry,
20 -Porch,
21 -Public Bar,
22 -Rear of shop,
23 -Saloon Bar,
24 -Shed,
25 -Shop Front,
26 -Shop Window,
27 -Staff Room,
28 -Store Room,
29 -Toilet,
30 -Under Counter
31 -Waiting Room
32 -Meter Box (Outside),
98 -Other,
99 -Outside.
METER_SERIAL_NUMBER / MM / T / 14 / 0 / The manufacturer's meter serial number as held on the physical meter.
SUPPLY_METER_POINT_AQ / M / N / 15 / 0 / The annual offtake quantity of a Supply Meter Point. This AQ may be revised following read submission.
DRE_SERIAL_NUMBER / O / T / 14 / 0 / DEFINITION: The manufacturer’s serial number.
DRE_UNIQUE _NUMBER / O / T / 18 / 0 / A system generated number allocated to each individual daily read equipment record within a location to provide unique identification.
METER_LINK_CODE / O / T / 1 / 0 / DEFINITION: A code defining the functional relationship between meters (the way in which they are linked together) at a given location on the End User’s site. CONTEXT: Populated only when output in conjunction with a RT_S64_OFFER recorded.
VALUES:
P -Primary Meter,
S -Sub-meter,
F -Free Standing Meter,
.
CORRECTION_FACTOR / O / N / 9 / 6 / This is a fixed factor based on pressure/altitude/temperature
OPERATIONAL_STATUS / O / D / 8 / 0 / DEFINITION: Indicates the current operational status of the Meter Point, be it Live, Isolated or Pending Isolation. CONTEXT: Status can be derived by evaluating the value of the field. Live -Not Populated, Isolated -Populated with date in future.
FORMAT: YYYYMMDD
METER_MECHANISM / O / T / 3 / 0 / DEFINITION: The coded value of the description of the Meter Mechanism.
ALLOWABLE VALUES:
CR -Credit,
MT -Mechanical Token,
ET -Electronic Token,
CM -Coin,
PP -Prepayment,
TH -Thrift,
U -Unknown,
NS - SMETS non-compliant
S1 - SMETS Version 1
S2 - SMETS Version 2.
NUMBER_OF_DIALS_OR_DIGITS / M / N / 2 / 0 / DEFINITIONS: Number of dials or digits on the meter which are considered during meter reading. Used to validate meter readings and to determine the number of
complete units consumed. Note: Since there may be cases where the Meter Model is not found (this can be legitimate), there is no error if the meter model for the Meter Point is not found. In this case, the METER_MECHANISM will be set to spaces and the
NUMBER_OF_DIALS_OR DIGITS will be set to 0.
PREVIOUS_SUPPLIER_SHORT_CODE / O / T / 3 / 0 / DEFINITION: A unique short code which gives the identity of the previous supplier for the meter point. CONTEXT: Populated only when output in conjunction with an
RT_S15_TRANSFER_OF_OWNERSHIP.
FORMULA YEAR SMP AQ / O / N / 15 / 0 / The Supply Meter Point AQ that is fixed throughout the formula year for determination of Transportation rates. For Class 3 and Class 4 Supply Meter Points.
AMR_INDICATOR / M / T / 1 / 0 / Indicator to identify whether the site has AMR attached. VALUE: “Y/N”
Total / 118
RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE : S75
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
METER_LOCATION_CODE / M / N / 2 / 0 / DEFINITION: A code representing the location of a meter.
VALUES: 0 -Unknown,
1 -Cellar,
2 -Under Stairs,
3 -Hall,
4 -Kitchen,
5 -Bathroom,
6 -Garage,
7 -Canteen
8 -Cloakroom,
9 -Cupboard,
10 -Domestic Science
11 -Front Door,
12 -Hall Cupboard
13 -Kitchen Cupboard
14 -Kitchen Under Sink
18 -Outside WC,
19 -Pantry,
20 -Porch,
21 -Public Bar,
22 -Rear of shop,
23 -Saloon Bar,
24 -Shed,
25 -Shop Front,
26 -Shop Window,
27 -Staff Room,
28 -Store Room,
29 -Toilet,
30 -Under Counter
31 -Waiting Room
32 -Meter Box (Outside),
98 -Other,
99 -Outside.
METER_SERIAL_NUMBER / O / T / 14 / 0 / The manufacturer's meter serial number as held on the physical meter.
SUPPLY_METER_POINT_AQ / M / N / 15 / The annual offtake quantity of a Supply Meter Point. This AQ may be revised following read submission.
DRE_SERIAL_NUMBER / O / T / 14 / 0 / DEFINITION: The manufacturer’s serial number.
DRE_UNIQUE _NUMBER / O / T / 18 / 0 / A system generated number allocated to each individual daily read equipment record within a location to provide unique identification.
METER_LINK_CODE / O / T / 1 / 0 / DEFINITION: A code defining the functional relationship between meters (the way in which they are linked together) at a given location on the End User’s site. CONTEXT: Populated only when output in conjunction with a RT_S64_OFFER recorded.
VALUES:
P -Primary Meter,
S -Sub-meter,
F -Free Standing Meter,
.
CORRECTION_FACTOR / O / N / 9 / 6 / This is a fixed factor based on pressure/altitude/temperature
OPERATIONAL_STATUS / O / D / 8 / 0 / DEFINITION: Indicates the current operational status of the Meter Point, be it Live, Isolated or Pending Isolation. CONTEXT: Status can be derived by evaluating the value of the field. Live -Not Populated, Isolated -Populated with date in future.
FORMAT: YYYYMMDD
METER_MECHANISM / O / T / 3 / 0 / DEFINITION: The coded value of the description of the Meter Mechanism.
ALLOWABLE VALUES:
CR -Credit,
MT -Mechanical Token,
ET -Electronic Token,
CM -Coin,
PP -Prepayment,
TH -Thrift,
U -Unknown,
NS - SMETS non-compliant
S1 - SMETS Version 1
S2 - SMETS Version 2.
NUMBER_OF_DIALS_OR_DIGITS / M / N / 2 / 0 / DEFINITIONS: Number of dials or digits on the meter which are considered during meter reading. Used to validate meter readings and to determine the number of
complete units consumed. Note: Since there may be cases where the Meter Model is not found (this can be legitimate), there is no error if the meter model for the Meter Point is not found. In this case, the METER_MECHANISM will be set to spaces and the
NUMBER_OF_DIALS_OR DIGITS will be set to 0.
PREVIOUS_SUPPLIER_SHORT_CODE / O / T / 3 / 0 / DEFINITION: A unique short code which gives the identity of the previous supplier for the meter point. CONTEXT: Populated only when output in conjunction with an
RT_S15_TRANSFER_OF_OWNERSHIP.
FORMULA YEAR SMP AQ / O / N / 15 / 0 / The Supply Meter Point AQ that is fixed throughout the formula year for determination of Transportation rates. For Class 3 and Class 4 Supply Meter Points.
AMR_INDICATOR / M / T / 1 / 0 / Indicator to identify whether the site has AMR attached. VALUE: “Y/N”
Total / 118

RT_S98_SMART_DATA

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / DEFINITION: A code identifying the type of request that this record represents. VALUE: S98
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
SMSO_ID / O / T / 3 / 0 / The identity of the operator, a Supplier has procured data and communication services from, in respect of a Smart Metering System.
SMSO_EFD / O / D / 8 / 0 / The date on which the Smart Meter System Operator becomes effective. FORMAT : YYYYMMDD
DCC_SERVICE_FLAG / O / T / 1 / 0 / A DCC provided flag to indicate the status of the services being provided by the DCC to a Meter. Allowable values: A Active S Suspended W Withdrawn
DCC_SERVICE_FLAG_EFD / O / D / 8 / 0 / The first inclusive calendar date for which the status of the DCC Service flag applies. FORMAT : YYYYMMDD
IHD_INSTALL_STATUS / O / T / 1 / 0 / Information from the Supplier regarding the status/existence of the In Home Display at a metering point. Allowable values: I Installed E Existing D Declined
FIRST_SMETS_INSTALLATION_ DATE / O / D / 8 / 0 / First SMETS Meter Installation date for a Meter Point Reference provided by the incumbent Shipper. FORMAT : YYYYMMDD
UNIQUE_PROPERTY_REF_NO / O / T / 12 / 0 / A Unique Property Reference Number (UPRN) is an attribute of a Basic Land and Property Unit (BLPU). It is a unique reference number that can be linked to further address information that is collated and provided by the Ordnance Survey Group. This field will not be populated until a governance is agreed
NWO_SHORT_CODE / O / T / 3 / 0 / A unique three character code used to identify a Network Operator.
NETWORK_OWNER_ID_EFD / O / D / 8 / 0 / Date the network owner is effective for that Meter Point. FORMAT : YYYYMMDD
Total / 65

RT_K12_MAM_GAO_DETAILS

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / DEFINITION: A code identifying the type of request that this record represents. VALUE : K12
GAS_ACT_OWNER / M / T / 1 / 0 / DEFINITION: Unique code which identifies the role the market participant is acting in.
Indicates the Gas Act Meter Ownership Type for a meter.
The permitted values being,
T - Transporter Owned Meter
S - Supplier Owned Meter
C - Consumer Owned Meter
U – Unknown
Where no GAO has been provided, the field shall be set to ‘U’. Where no meter is fitted, the latest GAO notified for a meter at that meter point shall be provided.
CURRENT_METER_ASSET_MANAGER / M / T / 12 / 0 / DEFINITION: The Short code for the MAM associated with the meter.
A unique identifier to describe the current meter asset manager responsible for the meter assets. This will be populated with UNKNOWN if there is not a current MAM recorded or if UNKNOWN was supplied.
PROSPECTIVE_METER_ASSET_MANAGER / O / T / 12 / 0 / DEFINITION: Prospective meter asset manager short code. A unique identifier to describe the prospective meter asset manager responsible for the meter assets at the meter point. This will be populated with the supplied MAM (including UNKNOWN) whilst the supplied effective date relevant to that MAM remains in the future.
PROSPECTIVE_MAM_EFFECTIVE_
DATE / O / D / 8 / 0 / DEFINITION: The date on which prospective meter asset manager becomes responsible for the meter assets at the Supply Meter Point. Populated if provided and will be present if Prospective Meter Asset Manager is present.
FORMAT: YYYYMMDD
Total / 36

RT_K85_GENERIC_ORG_NOTIFICATION

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents. VALUE: K85
METER_POINT_REFERENCE / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network.
ORGANISATION_SHORT_CODE / M / T / 3 / 0 / This field identifies the three character unique Organisation short code.
ORGANISATION_TYPE / M / T / 3 / 0 / Contains the name of Organisation Type.
Allowable values: ASP – AMR Service Provider
EFFECTIVE_DATE / M / D / 8 / 0 / Date from which Organisation notification is effective for given meter point.
FORMAT: YYYYMMDD
STATUS / M / T / 2 / 0 / The status of the Organisation type.
Allowable values: LI – Live
ED – End Date
Total / 29

RT_U71_NTS_OPTIONAL_RATE_DET