Sewage Pump Station

Design Information

What city or authority will the station be located?

What is the actual site name? (street, road, ect...)

What are the pump conditions? ______GPM @ ______TDH

What power is available? _____ wire/_____ phase/60 hertz/______(120/208/230/460)

What is the proposed grade elevation? ______What is the proposed slab elevation? ______

What type of pumping station is best for the application?

Flooded suction with dry pit non-clog pumps

Vertical builtogether or vertical flex coupled pumps

Typically the most efficient for flows 100 GPM and higher

Positive suction head required

Longest practical design life (20+ years)

Widest pump condition range

More easily applied to special requirements (flowmeters, ect...)

Most reliable with low maintenance costs

Vacuum-Priming

Wet Well Mounted

Fiberglass enclosure

Maximum suction lift of 16'

Semi-Buried (If high suction lift is greater than 16')

Vertical builtogether pumps

Lower initial and installation costs, however, more costly to maintain

More accessible than flooded suction stations

Self- Priming

Wet well mounted

Fiberglass enclosure

Buried can station

Shallower bury than flooded suction due to self-prime capacity

Less efficient than flooded suction

Pneumatic Ejector

More efficient for flows under 100 GPM

No wet well required

What size pump chamber? ______(7,8,9,10,11,12, 13, 14 or obround) foot diameter

______What is the desired inside height

What diameter entrance tube? 36 inch or 48 inch

Is a maintenance lift an option?

Is a separate equipment tube an option? (Normally installed in large obround stations)

What type of cathodic protection? Anode packs

How many packs?

Is an anode test panel required?

Impressed current

Any special coatings on the chamber and entrance tube exterior?

Fiberglass coating

Polyurethane foam insulation

Other ______

Pump Selection

How many pumps required? (Minimum should be two)

Pump performance?

Speed (900 RPM - 1200 RPM - 1800 RPM)

Desired efficiency?

Pump motors enclosure type (ODP (typical) - TEFC)

Pump drive configuration (builtogether - flexible coupled - v-belt drive)

Pump with mechanical seals or packing? (Mechanical seals are standard)

What type of piping? Ductile Iron (standard)

Steel (standard for vacuum prime type stations)

What size of piping? (Typically limited velocities from 2 FPS to 7 FPS)

What type of isolation valves? Plug valves

Resilient wedge gate valves

Double disc gate valves

What type of check valves? Lever & spring

Lever & weight

Cushioned (air or oil)(normally for high head applications)

Other ______

Any special options? Flow meters

Vibration isolators

Other ______

What type of power and control enclosure? (Nema 1 is standard)

Is a single-phase transformer required?

What type of starters? Across the line

Reduced voltage

Other ______

What type of level controls?

Mercury float Switches

Bubbler type level controller

Standard

Solid State

Ultrasonic level controller

Submersible transducer

Other ______

What Alarm functions are required?

High wet well

Low wet well

Station Flooding

Pump fail

Pump temperature

Power Failure

Unauthorized entry

Other ______

What type of alarm indicators?

120 Volt alarm light and horn

12 Volt alarm light and horn with battery backup

Telephone dialer

Telemetry

What type of environmental equipment?

Lighting

Incandescent

Fluorescent

Ventilation Blower (standard)

Heater (standard)

Dehumidifier (standard below grade)

Sump Pump (standard below grade)

Emergency lighting

Other ______

Any pressure gauges required?

Designers and Fabricators of Water & Wastewater Pumping Stations