1 GENERAL

1.1 SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

1.1.1 Cold Storage Doors:

1.1.1.1 FasTrax FR.

1.1.1.2 Barrier Glider Door.

1.1.1.3 Iso-Tek Door.

1.1.2 Fabric Overhead Doors:

1.1.2.1 BugShield Screen Roll-Up Door.

1.1.2.2 BugShield Screen Sliding Door.

1.1.2.3 Dok-Dor.

1.1.3 High Speed Doors:

1.1.3.1 FasTrax High Performance Door.

1.1.3.2 FasTrax Clean High Performance Door.

1.1.3.3 SplitSecond High Performance Door.

1.1.3.4 SplitSecond Clean High Performance Door.

1.1.3.5 TrakLine Roll High Performance Door.

1.1.3.6 TrakLine Fold High Performance Door.

1.1.3.7 TrakLine PLUS High Performance Door.

1.1.3.8 LiteSpeed High Performance Door

1.1.3.9 LiteSpeed Clean High Performance Door.

1.1.4 Machine Guarding:

1.1.4.1 Guardian Defender Machine Guarding Door.

1.1.4.2 FlashFold Vertical Rising Automated Barrier Door.

1.2 RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

1.2.1 Section 26 05 00 - Common Work Results for Electrical.

1.3 REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

1.3.1 ASTM International (ASTM):

1.3.1.1 ASTM A 526 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Commercial Quality.

1.3.1.2 ASTM D 1929 - Standard Test Method for Determining Ignition Temperature of Plastics.

1.3.1.3 ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.

1.3.1.4 ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Uniform Static Air Pressure Difference.

1.3.2 cGMP - Federal Current Good Manufacturing and Product Quality Standard.

1.3.3 NEMA - National Electrical Manufacturers Association.

1.3.4 I.C.B.O - International Council of Code Officials.

1.3.5 UBC 17-5 - Room Fire Test Standard for Interior of Foam Plastics Systems (Corner Room Burn).

1.3.6 FDA - US Food and Drug Administration.

1.3.7 Underwriters Laboratories Inc. (UL) 508 - Standard of Safety for Industrial Control Equipment.

1.4 SUBMITTALS

1.4.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.

1.4.2 Product Data: Manufacturer's data sheets on each product to be used, including:

1.4.2.1 Preparation instructions and recommendations.

1.4.2.2 Storage and handling requirements and recommendations.

1.4.2.3 Installation methods.

1.4.3 Shop Drawings: showing overall dimensions (width, height) and location of electrical service panels and motor locations.

1.4.4 Closeout Submittals:

1.4.4.1 Submit manufacturer's owner's manual, maintenance manual and master service manual.

1.4.4.2 Manufacturer's warranty.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

1.4.5 Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

1.4.6 Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.5 QUALITY ASSURANCE

1.5.1 Manufacturer Qualifications: Providing sole source for design, engineering, manufacturing and warranty claims handling.

1.5.2 Installer Qualifications: Trained and certified by manufacturer.

1.6 DELIVERY, STORAGE, AND HANDLING

1.6.1 Store products in manufacturer's unopened packaging until ready for installation.

1.6.2 Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.7 PROJECT CONDITIONS

1.7.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.8 WARRANTY

** NOTE TO SPECIFIER ** FasTrax warranty. Delete if not required.

1.8.1 The manufacturer shall provide a 2-year limited warranty on parts and labor, including electrical.

** NOTE TO SPECIFIER ** Glider and Roll-Up door warranty. Delete if not required.

1.8.2 The manufacturer shall provide a 1-year limited warranty on parts and labor, including electrical.

1.8.3 The manufacturer shall warrant that the equipment will perform in a manner satisfactory to the Owner for a period of 12 months after the date of installation. If the Owner is not satisfied with the performance of the equipment, the Owner may notify the manufacturer and the manufacturer shall remove the equipment and refund the equipment purchase price to the Owner.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: Rite-Hite, which is located at: 8900 N. Arbon Dr.; Milwaukee, WI 53223; Toll Free Tel: 888-214-0882; Tel: 414-355-2600; Fax: 414-355-9248; Email:request info (); Web:

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

2.1.2 Substitutions: Not permitted.

2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

** NOTE TO SPECIFIER ** Rite-Hite Doors line of cooler and freezer doors has a design which can help improve the productivity and efficiency of cold storage facilities. Our line-up includes bi-parting doors, high speed roll-up doors, bi-rolling doors and impact doors. Reflek-Tek™ insulated panels help block the infiltration of heat and humidity. Delete if not required.

2.2 COLD STORAGE DOORS

** NOTE TO SPECIFIER ** Delete if not required.

2.2.1 High Speed Roll-Up Cold Storage Doors: FasTrax FR Series as manufactured by Rite-Hite.

2.2.1.1 Design: Curtain retention wear resistant wind guides providing tension over the entire length of the side frame. Door shall have TRUE Auto Re-Feed, which automatically positions the curtain back into the side frame after an impact without manual intervention or resetting at the control box. Door shall not have limit switches operating within the side frames. Door shall have a soft bottom edge which yields in the horizontal plane when impacted. Door shall not have metal bottom bars, springs, pulleys or counterweights. Door shall not have coil cords, junction boxes or any other external electronics within the door opening or the door curtain.

** NOTE TO SPECIFIER ** Delete model not required.

2.2.1.2 Model: FasTrax FR (Vertical Lift).

2.2.1.3 Model: FasTrax FR (High Lift).

2.2.1.4 Model: FasTrax FR (Standard Lift).

2.2.1.5 Model: FasTrax FR (45 Deg Tiltaway).

2.2.1.6 Size: 10 feet wide by 18 feet high (3048 mm by 5486 mm) maximum.3 feet wide by 3 feet high (915 mm by 915 mm) minimum. Refer to drawings.

2.2.1.7 Curtain Material: 1 inch (25 mm) thick insulated fabric panel (standard color: blue). Curtain shall have an R-4 insulating value. InsulMax as manufactured by Rite-Hite.

2.2.1.8 Side Frames: Powder coated extruded aluminum construction.

2.2.1.9 Speed: Minimum - 48 inches (1219 mm)/second minimum to 100 inches (2540 mm) per second. Maximum speed is determined by door size.

2.2.1.10 Drive System: Motor shall be 2 HP electric motor with direct drive gearbox. Variable frequency drive. Drive system shall consist of a drive gear, drive spheres and a composite edge material attached to the curtain. Door shall have a hand operated brake disconnect for emergency manual operation.

** NOTE TO SPECIFIER ** Optional chain hoist manual operation. Delete if not required.

2.2.1.11 Door shall have manual opening using a chain hoist.

** NOTE TO SPECIFIER ** Delete electrical requirements not required.

2.2.1.12 Electrical Requirements: Single phase 220-240V, 60 HZ.

2.2.1.13 Electrical Requirements: Three phase 208V, 60 HZ.

2.2.1.14 Electrical Requirements: Three phase 240V, 60 HZ.

2.2.1.15 Electrical Requirements: Three phase 400V, 50/60 HZ.

2.2.1.16 Electrical Requirements: Three phase 460V, 60 HZ.

2.2.1.17 Electrical Requirements: Three phase 575V, 60 HZ.

2.2.1.18 Thermal Air Seal: Sealing system designed to circulate warm air through 4-1/2 inches (114 mm) diameter fabric tubes around wall perimeter of opening.

** NOTE TO SPECIFIER ** Delete electrical requirements not required.

2.2.1.18.1 Electrical Requirement: Single phase, 120 VAC, 50/60HZ.

2.2.1.18.2 Electrical Requirement: Transformer matching controller voltage.

2.2.1.19 Controller: Mounted inside NEMA 4X UL listed control box with open push button and on/off switch. Controller shall be digital i-COMM variable frequency drive as manufactured by Rite-Hite Corp.

2.2.1.20 Door Activation: Door shall be activated by one of the following: Induction loop, motion sensor, electronic eye, push button control, radio control, pull cord or other methods. Refer to drawings.

2.2.1.21 Safety Equipment: Door controls shall be listed to applicable US and Canadian safety standards by Underwriters Laboratories Inc. (UL) 508. Door shall be CE compliant.

2.2.1.21.1 Door shall include two reversing thru-beam photo eyes mounted at 18 inches (457 mm) and 54 inches (1372 mm) to monitor the door opening, and reverse the curtain if obstructed.

2.2.1.21.2 Door shall have Virtual Vision light communication system to alert personnel to objects, equipment or personnel moving on the opposite side of the door opening.

** NOTE TO SPECIFIER ** Delete if not required.

2.2.1.21.3 Door shall have I-Zone area detection system, which detects pedestrians moving within an area of three feet on either side of the door opening and within the opening and reverses the downward direction if activated.

2.2.1.21.4 If power failure occurs, brake holds door in place and can be released manually.

2.2.1.22 Curtain Fans: Two curtain fans mounted for air coverage on warm side of curtain.

** NOTE TO SPECIFIER ** Delete if not required.

2.2.2 Bi-Parting Cold Storage Doors: Barrier Glider Iso-Tek Door Panel System as manufactured by Rite-Hite.

2.2.2.1 Design: Door shall include a thick, insulated nose to assure a tight seal at the leading edge. All seals shall be replaceable. No doors shall be accepted that do not have replaceable seals. Tubular header and support beams shall be heavy-gauge steel for long-term durability. Two steel trolleys shall travel on the round track via hourglass-shaped urethane rollers. Roller shape and tubular track shall allow the panels to rotate on track for enhanced panel impactability. No door shall be accepted that requires a heated panel defrost system. Panel retention system shall keep panels tight against the seals, yet allow panels to swing away from the wall and automatically reset. No doors shall be accepted without automatic reset after impact.

2.2.2.2 Temperature Range: -20 degrees to +120 degrees F (-29 degree to 49 degree C).

** NOTE TO SPECIFIER ** Delete model not required.

2.2.2.3 Model: 7100 Barrier Glider, Bi-Part, Flexible Panel.

2.2.2.4 Model: 7100 Barrier Glider, Single Slide, Flexible Panel, Lead Edge Motor Location.

2.2.2.5 Model: 7100 Barrier Glider, Single Slide, Flexible Panel, Storage Side Motor Location.

** NOTE TO SPECIFIER ** Manual slider. Delete references to motor and opening speeds. Delete if not required.

2.2.2.6 Model: 7100 Barrier Glider, Manual Single Slide, Flexible Panel.

2.2.2.7 Size: 10 feet wide by 16 feet high (3048 mm by 4877 mm) maximum. 7 feet wide by 8 feet high (2134 mm by 2438 mm) minimum. Refer to drawings.

2.2.2.8 Header/Trolley: 3 inches (76 mm) round steel tube header with hour shaped urethane rollers supporting panels.

2.2.2.9 Support Tubes: 1 inch by 3 inches by 11 ga (25 mm by 76 mm by 3.0 mm) steel tube.

** NOTE TO SPECIFIER ** Motorized doors only. Delete speed not required.

2.2.2.10 Speed: Bi-Parting power doors shall have an opening speed of 60 inches (1524 mm per second and a closing speed of 30 inches (762 mm) per second.

2.2.2.11 Speed: Single-slide power doors shall have an opening speed of 30 inches (762 mm) per second and a closing speed of 15 inches (381 mm) per second.

2.2.2.12 Door Material: Door panels shall be 3 inches (76 mm) thick flexible panels, with insulating foam core and R-10 rating for enhanced impactability.

** NOTE TO SPECIFIER ** Delete fabric color not required.

2.2.2.12.1 Panels shall be covered with 30 oz. gray polyurethane fabric.

2.2.2.12.2 Panels shall be covered with 30 oz. white polyurethane fabric.

** NOTE TO SPECIFIER ** Option. Available with flexible panels only. Delete if not required.

2.2.2.12.3 Door panel shall have 4-pane, 16 inches by 34 inches (406 mm by 864 mm) vision panels.

** NOTE TO SPECIFIER ** Motorized doors only. Delete speed not required.

2.2.2.13 Drive System: AC drive system.

** NOTE TO SPECIFIER ** Motor options: Delete if not required.

2.2.2.13.1 Provide motor cover.

** NOTE TO SPECIFIER ** Motorized doors only. Delete electrical requirements not required.

2.2.2.14 Electrical Requirements: Single phase 220V, 60 HZ.

2.2.2.15 Electrical Requirements: Three phase 208-230V, 60 HZ.

2.2.2.16 Electrical Requirements: Three phase 460V, 60 HZ.

2.2.2.17 Electrical Requirements: Three phase 575V, 60 HZ.

2.2.2.18 Thermal Air Seal: Sealing system designed to circulate warm air through 4-1/2 inches (114 mm) diameter fabric tubes around wall perimeter.

** NOTE TO SPECIFIER ** Delete electrical requirements not required.

2.2.2.18.1 Electrical Requirement: Single phase, 120 VAC, 50/60HZ.

2.2.2.18.2 Electrical Requirement: Single phase, 220 VAC, 50/60HZ.

2.2.2.18.3 Electrical Requirement: Transformer matching controller voltage.

** NOTE TO SPECIFIER ** Motorized doors only. Delete if not required.

2.2.2.19 Controller: Mounted inside NEMA 4X or NEMA 12 UL listed control box with open push button which flashes during a fault condition and power disconnect switch. Controller shall be digital i-COMM solid state logic controller and cycle counter as manufactured by Rite-Hite Corp.

** NOTE TO SPECIFIER ** Motorized doors only. Delete if not required.

2.2.2.20 Door Activation: Door shall be activated by one of the following: Induction loop, motion sensor, electronic eye, push button control, radio control, pull cord or other methods. Refer to drawings.

2.2.2.21 Safety Equipment: Door controls shall be listed to applicable US and Canadian safety standards by Underwriters Laboratories Inc. (UL) 508. Door shall be CE compliant.

2.2.2.21.1 Door shall have flexible panels to help prevent impact damage.

2.2.2.21.2 Panel retention system and tubular track/roller system shall allow panel to rotate on track.

** NOTE TO SPECIFIER ** Motorized doors only. Delete if not required.

2.2.2.21.3 Door shall have automatic reopen when an object in the opening prevents panels from closing.

** NOTE TO SPECIFIER ** Motorized doors only. Delete if not required.

2.2.2.21.4 No external electronics or sensing devices shall be placed on leading edge of panels.

** NOTE TO SPECIFIER ** Delete if not required.

2.2.3 Bi-Parting Rolling Cold Storage Doors: High Speed Iso-Tek Cold Storage Door System as manufactured by Rite-Hite.

2.2.3.1 Design: Door shall include a thick, insulated door panels. All seals shall be replaceable. No doors shall be accepted that do not have replaceable seals. Two steel trolleys per panel shall travel on the round track via hourglass-shaped urethane rollers. Roller shape and tubular track shall allow the panels to rotate on track for enhanced panel impactability. No door shall be accepted that requires a heated panel defrost system. Panel retention system shall keep panels tight against the seals, yet allow panels to swing away from the wall and automatically reset. No doors shall be accepted without automatic reset after impact.

2.2.3.2 Temperature Range: -20 degrees to +120 degrees F (-29 degree to 49 degree C).

** NOTE TO SPECIFIER ** Delete model not required.

2.2.3.3 Model: 8600 Cold Storage Door - 2-Panel Configuration.

2.2.3.4 Model: 8600 Cold Storage Door - 4-Panel Configuration.

2.2.3.5 Model: 8600 Cold Storage Door - Single-Slide Configuration.

2.2.3.6 Size: 7 feet-3 inches wide by 18 feet high (2210 mm by 5486 mm) maximum. 6 feet wide by 8 feet high (1829 mm by 2438 mm) minimum. Refer to drawings.

2.2.3.7 Header/Trolley: Two piece, 3/16 inch (4.8 mm) aluminum extrusion with two integral trolley paths -- one for the lead panel, and one for the follower panel. Two trolleys are attached to each panel. Trolley assembly is hinged for enhanced panel impactability. Header is canted 3 degrees, center to both ends for positive sealing and reduced seal wear. Self-supporting on two floor-mounted beams constructed of 2 inches by 3 inches by 1/8 inch (51 mm by 76 mm by 3 mm) aluminum tubing.

** NOTE TO SPECIFIER ** Delete door not required.

2.2.3.8 Speed: Bi-Parting power doors shall have an opening speed of 84 inches (2134 mm) per second and a closing speed of 20 inches (508 mm) per second.

2.2.3.9 Speed: Single-slide power doors shall have an opening speed of 42 inches (1067 mm per second and a closing speed of 20 inches (508 mm) per second.

2.2.3.10 Door Material: Door panels shall be 3 inches (76 mm) thick flexible panels, with insulating foam core and R-10 rating for enhanced impactability. Panels shall be covered with 30 oz. gray polyurethane fabric.

** NOTE TO SPECIFIER ** Option. Available with flexible panels only. Delete if not required.

2.2.3.10.1 Door panel shall have 4-pane, 14 inches by 32 inches (356 mm by 813 mm) vision panels.

2.2.3.11 Drive System: Synchronous 1-1/2 hp motor controlled by a pre-programmed AC inverter. Door commands are processed by a self-diagnostic Rite-Hite Programmable Logic Controller (PLC). Panels driven by a gearbox clutch belt drive system.

** NOTE TO SPECIFIER ** Delete electrical requirements not required.

2.2.3.12 Electrical Requirements: Single phase 220VAC, 30 A, 60 HZ.

2.2.3.13 Electrical Requirements: Three phase 208-230VAC, 30A, 60 HZ.

2.2.3.14 Electrical Requirements: Three phase 380/415VAC, 15A, 60 HZ.

2.2.3.15 Electrical Requirements: Three phase 460VAC, 15A, 60 HZ.

2.2.3.16 Electrical Requirements: Three phase 575VAC, 15A, 60 HZ.

** NOTE TO SPECIFIER ** Required on cold side freezer mount only. Closed system blower within header does not inject warm air into freezer. Requires second 12 inches by 10 inches by 6 inches (305 mm by 254 mm by 152 mm) control box (provided).

2.2.3.17 Thermal Air Seal: Sealing system designed to circulate warm air through 4-1/2 inches (114 mm) diameter fabric tubes around wall perimeter.

** NOTE TO SPECIFIER ** Delete electrical requirements not required.

2.2.3.17.1 Electrical Requirement: Single phase, 120 VAC, 50/60HZ.

2.2.3.17.2 Electrical Requirement: Single phase, 220 VAC, 50/60HZ.

2.2.3.17.3 Electrical Requirement: Transformer matching controller voltage.

2.2.3.18 Controller: Control box is NEMA 4X and fuse protected. Standard controls include "open" button which flashes upon a fault condition and a power disconnect. The box is prewired with external connections brought into pre-coded terminals. All as manufactured by Rite-Hite Corp.