Regional Transportation District Commuter Railroad / SOP #
RTDC-TR-AC-01
DTO RTDC Third Party ROW Access
RTD/DTO Commuter Rail Right of Way Access Request / Permit
Complete all fields that are in Blue(and have asterisks)
*Company Representing:*Person Submitting Request: / *Phone: / *Email:
*On Site Contact Person / *Phone: / *Email:
Requested Dates of Access (Not to Exceed 30 Days): / *From: / *To:
Requested Time Period (military): time) / *From: / *To:
Requested Location of Work time) / *From: / *To:
*Description of Work:
*Location:
*Equipment On Site:
Right of Way Access Rules:
- Access permit requests will be reviewed and granted upon completion of CRT Safety Training.
- Contractor must have Denver Transit Operators (DTO) qualified employees-in-charge (EIC) on-site at each work location.
The EIC’s time shall be compensated at the contractor’s expense. Contact for hourly rates.
- The overhead catenary (25,000 volts ac (nominal) is to be considered Live and Hot at all times. If de-energization is requested, contractor must confirm with DTO Traction Power personnel prior to entry. The time of the DTO Traction Power personnel performing the OCS de-energization shall be compensated at the contractor’s expense. Contact for inquiries, permitting, and hourly rates.
- A copy of this completed access permit must accompany the work crew on each work site.
- All personnel must wear required personal protective equipment (PPE) at all times.
- Contractor must notify their assigned EIC prior to entering and when clear of any job site.
- All active tracks must be 100% useable at all hours by the Commuter Rail trains. All rail flangeways and work areas must be cleared of debris prior to leaving the work area. Trains cannot be delayed.
Please email to
Requestor Confirmation and Agreement
*By checking this box, I acknowledge full understanding of RTD/DTO Access Permit rules and procedures and certify that RTDC on-track and electrical safety training has been completed and is current.
*Requestor: Type Name:______Sign Name:______Date______
FAILURE TO COMPLY WITH ACCESS PERMIT RULES WILL RESULT IN PERMIT REVOCATION
THE SECTION BELOW IS FOR RTD/DTO USE ONLY
Approved Dates of Access: / From: / To:Approved Time Period (military time): / From: / To:
Approved Limits of Access: / From: / To:
De-energize Overhead Power Required: / Yes / No
Operating Restrictions:
Signature: ______Date: ______
DTO – Chief Engineer
/ Permit NumberIssue Date: 08/24/2015 / Revision 1 / Page 1 of 1
Commercial in Confidence