Record Format Document

RT_X10_CLASS_CHANGE_CAN_RESP

Copyright Xoserve 2014©, all rights reserved.

No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / Xoserve
Owner: / Xoserve
Version: / 1
Status: / For Approval
Date: / 14-Oct-2014

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
0.1 / 1154 / Aug-2014 / 1-Oct-2015 / Preliminary file issued for representation
1 / 1154 / 14-Oct-2014 / 1-Oct-2015 / File issued for representation
Description rationalization
REQUESTED_DM_SOQ Length 10
REQUESTED_DM_SHQ Length 10

Notes

Note 1
OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places
Note 2
All text fields will be enclosed in double quotes ("")

Record Type Definition

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE / M / T / 3 / 0 / A code identifying the type of request that this record represents.
VALUE: X10
OUTCOME_CODE / M / T / 2 / 0 / Details whether the request has been accepted or rejected by the Transporters. VALUES: AC - Accepted, RJ - Rejected
SUPPLY_POINT_CONFIRMATION_REFERENCE / M / N / 10 / 0 / A sequential number that uniquely identifies the Confirmation.
NOMINATION_SHIPPER_REF / O / T / 30 / 0 / A reference supplied by the System User when making a Nomination. It may be used by the System User to identify the Nomination and any subsequent Confirmation made for that nomination.
SUPPLY_METER_POINT / M / N / 10 / 0 / A unique identifier for the point at which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Supply Meter Point References will only be created for new services or when a service is relayed to a different position.
SUPPLY_METER_POINT_CLASS / M / N / 1 / 0 / This value denotes the requested class type for the Supply Meter Point.
REQUESTED_SUPPLY_METER_POINT_CLASS / M / N / 1 / 0 / This value denotes the requested class type for the Supply Meter Point.
BATCH_SUBMISSION_FREQUENCY / O / T / 1 / 0 / A code identifying batch frequency for the class 3 meter.
VALUES: W - 7 days, F – 14 days, M - month
REQUESTED_DM_SOQ / O / N / 10 / 0 / The requested peak daily supply offtake quantity (SOQ) of a Supply Meter Point. CONTEXT: Only applicable to class 1 and 2.
REQUESTED_DM_SHQ / O / N / 10 / 0 / The requested peak hourly supply offtake quantity (SHQ) of a Supply Meter Point. CONTEXT: Only applicable to class 1 and 2.
REQUESTED_EFFECTIVE_DATE / M / D / 8 / 0 / The date on which the class change request will be effective.
FORMAT: YYYYMMDD
Total / 86

RT_X10_CLASS_CHANGE_CAN_RESPPage 1 of 4Issue Date: 14-Oct-2014

Version: 1 For ApprovalImplementationDate: 1-Oct-2015