Record Format Document

RT_Q01_ ELIGIBLE_SUPPLY_METER_POINT

Copyright Xoserve 2014©, all rights reserved.

No part of this publication may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of Xoserve except in accordance with the provisions of the Copyright, Designs and Patents Act 1998.

Author: / Xoserve
Owner: / Xoserve
Version: / 6
Status: / For Approval
Date: / 30-Sep-2014

Version Control

Version / COR / Issue Date / Implementation Date / Summary of Change
5 / Current Live Version
6 / 1154 / 30-Sep-2014 / 1-Oct-2015 / File issued for representation

Notes

Note 1
OPT - Optional/Mandatory (O - Optional, M - Mandatory)
DOM - Domain (T - text, N - Numeric, D - Date (YYYYMMDD), M - Timestamp)
LNG - Number of characters
DEC - Number of decimal places
Note 2
All text fields will be enclosed in double quotes ("")

Record Type Definition

RECORD/FIELD NAME / OPT / DOM / LNG / DEC / DESCRIPTION
TRANSACTION_TYPE RECORD_TYPE / M / T / 3 / 0 / A code identifying the type of information that this record contains. VALUE: Q01
LDZ_IDENTIFIER LDZ / M / T / 4 / 0 / This field identifies the LDZ to which the supply meter point is associated.
EXIT_ZONE_IDENTIFIEREXIT_ZONE / O / T / 3 / 0 / This field identifies the Exit Zone Id to which the supply meter point is associated
SUPPLY_POINT_ID / O / N / 10 / 0 / This field identifies the supply point number. It has to be populated for UKLINK Supply point.
LOGICAL_METER_NUM / O / T / 10 / 0 / The Logical Meter Number of the CSEP and Unique Site. It has to be populated for the sites of CSEP and Unique Sites.
SITE_NAME / O / T / 50 / 0 / This is a site name of the site from CSEP and Unique Site.
The name of the site associated to the Supply Meter Point(s).
DM_SHQ / O / N / 10 / 0 / This field identifies the Supply Hourly Quantity (SHQ) of the DM component of the supply point. It will be populated for DM CSEP and Unique Site. It will not be populated for NDM CSEP site.
NDM_SHQ / O / N / 10 / 0 / This field identifies the Supply Hourly Quantity (SHQ) of the NDM component of the supply point. It will be populated for NDM CSEP. It will not be populated for DM CSEP and Unique Site.
DM_SOQ / O / N / 10 / 0 / This field identifies the Supply Offtake Quantity (SOQ) of the DM component of the supply point. It will be populated for DM CSEP and Unique Site. It will not be populated for NDM CSEP site.
NDM_SOQ / O / N / 10 / 0 / This field identifies the Supply Offtake Quantity (SOQ) of the NDM component of the supply point. It will be populated for NDM CSEP. It will not be populated for DM CSEP and Unique Site.
DM_AQ / O / N / 15 / 0 / This field identifies Annual Quantity (AQ) of the DM component of the supply point. It will be populated for DM CSEP and Unique Site. It will not be populated for NDM CSEP site.
NDM_AQ / O / N / 15 / 0 / This field identifies Annual Quantity (AQ) of the NDM component of the supply point. It will be populated for NDM CSEP. It will not be populated for DM CSEP and Unique Site.
NUM_INTRPTBL_DAYS / O / N / 3 / 0 / This field identifies the current number of interruptible days stored in the system applicable to the supply point. It will not be populated for the CSEP/US.
SUPPLY_METER_POINT MPO_REFERENCE / MO / N / 10 / 0 / An unique identifier for the point at which a meter is, has been or will be connected to the gas network. These references are less volatile than meter or service identifiers and do not change if the meter is replaced or the service is relayed to the same position. New Supply Meter Point References will only be created for new services or when a service is relayed to a different position. This field identifies the meter point reference number within the supply point. It will not be populated for the CSEP/US.
POSTCODE_INCODE INCODE / O / T / 4 / 0 / Standard PAF incode as defined in the PAF digest.This field identifies the incode of the meter point.
POSTCODE_OUTCODE OUTCODE / O / T / 4 / 0 / Standard PAF outcode as defined in the PAF digest This fields identifies the outcode of the meter point.
ADDRESS / O / T / 250 / 0 / This field defines the address of the Supply Meter_ Point which is combination of Building Name, Building Number and Principal Street
SUPPLY_TYPE / M / T / 4 / 0 / This field identifies the nominated supply type of the meter point. Permissible values are ‘SNI’, ‘TNI’ and ‘FIRM’
MPO_GNT_TYPE / O / T / 3 / 0 / This field identifies the gas nomination type associated with the meter point. Permissible values are ‘DME’, ‘DM’ and ‘NDM’. It will not be populated for the CSEP/US
SPO_AQ / O / N / 15 / 0 / This field identifies the total Annual Quantity associated with the Supply Point. Essentially sum of DM AQ and NDM AQ. It will not be populated for the CSEP/US
SITE_INDICATOR / M / T / 2 / 0 / This field contains the indicator to convey whether the site is a S&M UKLINK site or a NDM CSEP or a DM CSEP or an Unique Site. ‘SM’ for UKLINK Site ‘NC’ for NDM CSEP ‘DC’ for DM CSEP ‘US’ for Unique Site
SUPPLY_METER_POINT_SHQ / O / N / 10 / 0 / This field identifies the Supply Hourly Quantity (SHQ) of the supply meter point.
SUPPLY_METER_POINT_SOQ / M / N / 10 / 0 / This field identifies the Supply Offtake Quantity (SOQ) of the Supply Meter Point.
SUPPLY_METER_POINT_AQ / M / N / 15 / 0 / The annual offtake quantity of a Supply Meter Point. This AQ may be revised following read submission.
SUPPLY_POINT_CLASS / M / N / 1 / 0 / It defines the class type for the Supply Meter Point.
Total / 367
445

RT_Q01_ ELIGIBLE_SUPPLY_POINTPage 1 of 6Issue Date: 30-Sep-2014

Version: 6 For ApprovalImplementationDate: 1-Oct-2015