Press Information / News Release

21. December 2018

COOPER Crouse-Hinds (UK) Ltd:

Ex-lighting solution for Gorgon Gas Plant aligns the unique requirements of the local sea turtle population

COOPER Crouse-Hinds has engineered an explosion-proof fluorescent light fitting for the Chevron-operated Gorgon project. The unique requirements for this project included ensuring that the lighting solution minimised disturbance of the local sea turtle population, whilst also ensuring that the light fittings provide sufficient light, therefore satisfying the Health & Safety requirements of the plant operator, explains Graham Doran of COOPER Crouse-Hinds.

COOPER Crouse-Hinds will supply more than 20,000 explosion-proof (Ex Zone 1 and Zone 2) fluorescent light fittings for installation on the Liquefied Natural Gas (LNG) and domestic gas plant under construction as part of the Gorgon Project – one of the world’s largest natural gas projects. Shipping of the light fittings has already commenced, with the lighting units planned for delivery in volume batches throughout 2011 and 2012.

Not only do the light fittings have to meet strict Health & Safety requirements in terms of explosion-protection and ensuring that plant personnel can still distinguish the colour of safety and warning signs at the gas plant, they also have to ensure that disturbance of the local population of sea turtles caused by artificial light sources is minimised. These unique, dual requirements posed enormous engineering challenges for the lighting supplier.

COOPER Crouse-Hinds’ standard eLLK 92 fluorescent light fitting with special cover and light filter will be installed in general illumination duties across the gas plant. COOPER Crouse-Hinds will supply four different types of eLLK 92 light fitting, including its 2 x 18W, 2 x 36W standard, and 2 x 36W with battery back-up versions.

The project involves the phased construction of three, 5 million tonnes per annum (MTPA) Liquefied Natural Gas (LNG) plants on Barrow Island, as well as a domestic gas plant with the capacity to provide 300 terajoules per day to supply gas to Western Australia. Gorgon LNG will be offloaded via a 4km long jetty for transport to global markets. The domestic gas will be piped to the Western Australian mainland.

The complexity and sheer scale of Gorgon is unprecedented. The gas field being tapped into contains around 40 trillion cubic feet of LNG. The project is a long term, technically complex energy development that signifies a dramatic advancement in engineering.

The Local Turtle Population

At Barrow Island, Gorgon occupies around 1.3 per cent of the island’s un-cleared landmass. The island is a Class A Nature Reserve. The island is an important nesting area for sea turtles. For more than 40 years, it has been home to an active oil field and turtle rookery. Sea turtles nest on the island’s beaches between October and March each year. Ongoing conservation efforts are reflected in the stringent environmental conditions set by the State and Australian Governments as part of the Gorgon Project approval process.

One of the requirements of the Gorgon Project is that plant lighting’s disturbance of local turtle populations should be minimised. In other words, any artificial light must not disturb turtle hatchling’s orientation towards the sea. As Graham Doran, Director Europe Global Projects Group at COOPER Crouse-Hinds puts it: “Having to ensure that our lighting solution meets the needs of different groups involved in the Gorgon Project – Environmental, Health & Safety, and Engineering – is a real challenge. One group of people wants a lighting solution that is as bright as possible so that plant personnel can carry out their work in safe, bright lighting conditions, whereas another group of people require anti-reflective lights that are as dim as possible in order to protect the sea turtles.”

Sea turtles and humans perceive light quite differently. Both the colour (wavelength) and relative brightness of light sources are critical in the sea-finding capabilities of hatchling sea turtles. Green turtles, for example, are strongly attracted to light in the near ultraviolet to yellow region of the visible spectrum (360 to 600nm) but are relatively indifferent to light in the yellow-orange to red region (630 to 700nm). The relatively high sensitivity of turtles to short wavelengths is not surprising considering that they live in a medium – the ocean – that selectively filters out long wavelength colours.

Gorgon Primary Lighting Requirements

In terms of the Gorgon processing plant, this means any lighting supplied must adhere to a strict set of requirements. In this case, the primary requirements are that the main light output is greater than 560nm in order to prevent turtles being attracted to the artificial light. The light fittings also have to be fit for use in hazardous industrial, Zone 1 and Zone 2 environments.

Another primary lighting requirement on Gorgon is that the colour-rendering index (CRI) of the lighting has to ensure safe working conditions for plant personnel. As Willi Steckel, Product Line Manager Lighting (IEC) at COOPER Crouse-Hinds GmbH, explains: “The CRI index measures how well a colour can be identified by the human eye under artificial light conditions. We had to make sure that our proposed lighting solution at 560-600nm could meet these requirements, so that plant personnel would still be able to identify the specific colours of safety escape signs and other colour-critical warning lamps. For example, a light source with a CRI of 20-25 would mean that the human eye could barely distinguish whether the colour was black, green or blue. It was therefore absolutely critical that the light fittings met these stringent requirements.”

According to Steckel, in order to solve the CRI issue, 20 to 30 different light filters were tested on the eLLK 92 light fitting. “After we found the appropriate filters, we then tested which one would give us the best colouring with the fluorescent tube. This part of the product testing alone took 8 months to complete. Finally, once we had a good selection of matches, we commenced the UV resistance testing of each filter type,” he recalls.

This stage of the testing also involved more than 1,000 hours of colour fade tests carried out in accordance with European Standards (Light Fastness Tests). These ensured that the colour of the filter did not fade under UV influence and maintains its properties for a minimum of 60,000 hours.

“The other primary requirement was that general illumination lighting would not be directed upwards from the plant into the sky, thus creating a halo effect around the plant, which would distract the sea turtles,” he adds. “We therefore developed different shielding arrangements depending on the mounting angle of the light fitting. Normally, a light fitting faces downwards but there are situations on a plant where a light may need to be mounted sideways and so for these units, we had to ensure that the light was supplied with the correct shielding for that particular mounting position.”

Secondary Lighting Requirements

There were also a number of secondary requirements for the lighting. The solution had to use proven technology; provide an optimised light output and optimised turtle orientation response factor; provide maximum time between inspection intervals and use future-compatible technology.

As Graham Doran states: “Our eLLK 92 light fitting is a reliable product, manufactured to superior quality levels and with an excellent reputation for long life and minimal maintenance in hazardous oil & gas installations.”

Independent Testing

“We commissioned the University of Applied Sciences in Hagen, Germany to conduct spectral analysis tests on the eLLK 92. The spectral distribution of light was measured on an explosion-protected light fitting with different light sources. Hagen verified all our tests in relation to the spectrum. The test results at Hagen confirmed that our own in-house measurements were correct,” explains Willi Steckel.

Minimal Maintenance Costs

To make use of the proven long life of the light fitting components, long life tubes were selected, which offers 60,000 hours between inspection intervals. This ensures minimal servicing and maintenance costs for the plant operator.

The lighting units had to meet certain wind speed requirements in case of unexpected cyclones (gale force winds) were encountered on Barrow Island. This meant that the
eLLK 92 had to be tested in the laboratory at wind speeds of up to 320km/h, in order to simulate a potential cyclone. “The eLLK 92 passed these tests with flying colours,” says Steckel.

The Recommended Lighting Solution

After more than 2 years of testing and development, COOPER Crouse-Hinds recommended its standard eLLK 92 Ex fluorescent light fittings for Zone 1 and Zone 2 areas, but fitted with a special cover and light filter. The light source is a T8 long life fluorescent white tube with light colour 830.

The light fittings use approved EVG09 ballast, housing and lamps, and are certified to the following standards: BVS 09 ATEX E 034; II 2G Ex de IIC T4. Recommended lamp change interval is 6 years, with a recommended cover change interval of 12 years.

“In my 40 years of working for this company, I cannot remember a project like this one in terms of the complexity of the primary and secondary lighting requirements. The engineering challenges that we’ve had to overcome on this project required all engineering and technical disciplines within COOPER Crouse-Hinds: R&D, testing, electronics, mechanical, and so on. It was a real collaborative effort here. Everyone here that is involved in the project has been completely driven and motivated to meet these unique challenges and project requirements,” enthuses Steckel.

For more information on COOPER Crouse-Hinds’ range of explosion proof fluorescent light fittings for hazardous gas environments, please contact the UK sales office on 02476 308930 or email or visit

ENDS [1,496 words]

Notes to Editors:

The Gorgon Project

The Gorgon Project is operated by Chevron and is a joint venture of the Australian subsidiaries of Chevron (47 per cent), ExxonMobil (25 per cent), Shell (25 per cent), Osaka Gas (1.25 per cent) and Chubu Electric Power Company (0.417 per cent).

COOPER Crouse-Hinds (UK) Ltd

As part of the COOPER Industries Group, COOPER Crouse-Hinds (UK) Ltd is the number one company in the field of explosion protection. Committed to technological progress, the company develops and manufactures a range of products that cover all the requirements currently placed on modern, explosion-protected, electrical installation technology, including illumination, safeguarding, signalling, controlling, instrumentation and distribution of electrical energy in potentially explosive atmospheres. In the company’s production plants in Germany, England and Spain, the company manufactures a wide range of products for explosion protection.

COOPER Crouse-Hinds supplies products that comply with all the latest directives and standards – worldwide. In addition to systems and components built to ATEX standards, the company also provides solutions that have been certified to both IEC and NEC standards. Moreover, the company also has a large number of other national approvals, e.g. for Eastern European countries, China and North America. With COOPER Crouse-Hinds you can get all you need from one source.

Editorial Enquiries to:

Dean Palmer, Director,
SilverBullet PR Ltd, Frith Farm, Ryhall Road, Tolethorpe, Stamford,
Lincolnshire, PE9 4BJ.
Tel (office): 01780 753 000

Tel (Mobile): 07703 023 771

Email:

Web:

Further Information:

Cooper Crouse-Hinds (UK) Ltd

Building 2, Argosy Court, Whitley Business Park, Simitar Way, Coventry CV3 4GA

Phone: 02476 308930Email:

Fax: 02476 301027 Internet: