Our hope is that this will be a place to look-up mixing impeller types from many vendors. If you are a mixing vendor, a mixing rep, or a graphic artist and you would like to see your impeller photos or CAD drawings here, with links to your site, please email us and let us know. Also let us know if you see your impeller here, but you name it differently. Information about these impeller designs will also be added below each picture, if available, and referenced to the source of that data. Turbulent data is quoted here for fully baffled conditions, unless noted. There will be a link to another page if more data is available.

Without baffles, most impellers styles impose a tangential flow pattern. With baffles, most impellers show their true flow characteristics.Impellers are sorted here by the flow patterns they were intended to create, radial flow impellers and axial flow impellers. Click on any of these images for a larger picture. If you can't find your impeller design here, see if it is stored under Special Impellers. Impeller design data includes impeller dimensions, number of blades, turbulent power number, turbulent flow number, and impeller synonyms. If you see a More Data link, click on it for flow pattern information and possibly non-turbulent power numbers (Np), flow numbers (Nq) and discharge angles as a function of Reynold's Number (Re).

Radial Impellers

/

Axial Impellers


/ RT3
/ Rushton Turbine with 3 blades
/ Np=3.3, Nq=0.62* D/T=0.33, wB/T=1/12
/ Np=3.4, Nq=0.62* D/T=0.33, wB/T=0.1
/ More Data
/ / RT4
/ Rushton Turbine with 4 blades
/ Np=4.3, Nq=0.68* D/T=0.33, wB/T=1/12
/ Np=4.4, Nq=0.68* D/T=0.33, wB/T=0.1
/ More Data
Impellers courtesy of P. Csiszar /
/ PR-D and PR-U
/ Chemineer AP-3
/ Lightnin A100 and A110
/ Propeller - Down-pumping and Up-pumping
/ Np=0.32 for 1.0 pitch, D/T=0.35, wB/T=0.1
/ Np=0.36 for 1.0 pitch, D/T=0.22, wB/T=0.1
/ Np=0.62 for 1.5 pitch, D/T=0.22, wB/T=0.1
/ Np=1.00 for 2.0 pitch, D/T=0.31, wB/T=0.1
/ Np=1.35 for 2.5 pitch, D/T=0.22, wB/T=0.1
/ Note: Subtract 0.01 from Np for wB/T=1/12
/ More Data
Impellers courtesy of P. Csiszar

/ RT5
/ Rushton Turbine with 5 blades
/ Np=5.4, Nq=0.73* D/T=0.33, wB/T=1/12
/ Np=5.4, Nq=0.73* D/T=0.33, wB/T=0.1
/ More Data
/ / RT6
/ Chemineer D-6
/ Lightnin R100
/ Hayward Gordon RD
/ Rushton Turbine with 6 blades
/ Np=5.2, Nq=0.72
/ Np=6.0, D/T=0.33, wB/T=1/12
/ Np=6.0, D/T=0.33, wB/T=0.1
/ More Data
Impellers courtesy of P. Csiszar /
/ 4PBT-D and 4PBT-U
/ Chemineer P-4
/ Lightnin A200
/ Pitched blade turbine - Down-pumping and Up-pumping with 4 blades
/ Np=1.27, Nq=0.79
/ More Data
/ / 6PBT-D
/ Pitched bladed turbine - Down-pumping with 6 blades
Impellers courtesy of P. Csiszar

/ RT8
/ Rushton Turbine with 8 blades
/ Np=7.8, Nq=0.82* D/T=0.33, wB/T=1/12
/ Np=7.8, Nq=0.82* D/T=0.33, wB/T=0.1
/ More Data
/ / RT12
/ Rushton Turbine with 12 blades
/ Np=9.9, Nq=0.89* D/T=0.33, wB/T=1/12
/ Np=10.0, Nq=0.90* D/T=0.33, wB/T=0.1
/ More Data
Impellers courtesy of P. Csiszar /
/ Lightnin A6000(down-pumper)
/ Advanced fiber reinforced composite, utilizing highly corrosion resistant plastic matrix, with proplets
/ Lightnin A6100(down-pumper)
/ Like the A6000 without proplets
/ Np=0.23, Nq=0.59
Impellers courtesy of K. McDermott

/ RP2
/ Paddle with 2 blades
/ No disk (disc)
/ / RP4
/ Lightnin R200
/ Paddle with 4 blades
/ No disk (disc)
/ Np=3.4, Nq=0.62*
Impellers courtesy of P. Csiszar /
/ Lightnin A310 or A510 (down-pumper)
/ Np=0.30, Nq=0.56
/ More Data
Impellers courtesy of K. McDermott and P. Csiszar

/ RP6
/ Paddle with 6 blades
/ No disk (disc)
Impellers courtesy of P. Csiszar /
/ Chemineer HE-3 (down-pumper)
/ Np=0.20, Nq=0.46 for D/T=0.5
/ Np=0.22, Nq=0.47 for D/T=0.4
/ Np=0.26, Nq=0.49 for D/T=0.3
/ Np=0.30, Nq=0.50 for D/T=0.2
/ More Data
Impellers courtesy of Chemineer

/ Holmes & Narver pumper mixer
/ Lightnin R300
/ Np, Nq, and Nh-values
/ CFD study
Impellers courtesy of P. Csiszar /
/ Lightnin A312
/ impeller mainly for side entry applications

/ Curved bladed pumper
/ Lightnin R320
/ Philadelphia Mixers CBT-6
/ Pumper impeller used for solvent extraction mixer settlers
/ 6-curved blades on one side of disk
/ CFD study
Impellers courtesy of P. Csiszar /
/ Lightnin A320 (down-pumper)
/ Np=0.64, Nq=0.64
/ More data
/ / Lightnin A340 (up-pumper)
/ Np=0.64, Nq=0.64
/ More data
Impellers courtesy of P. Csiszar

/ RS6
/ Chemineer CD-6
/ Lightnin R130
/ Philadelphia Mixers Smith Turbine
/ Hayward Gordon RDC
/ Np=3.2, Nq=0.61*
/ More Data
Impellers courtesy of P. Csiszar /
/ Lightnin A315 (down-pumper)
/ Np=0.75, Nq=0.73
/ / Lightnin A345 (up-pumper)
/ Np=0.75, Nq=0.73
Impellers courtesy of P. Csiszar

/ Chemineer BT-6
/ Np=2.3, Nq=0.55*
/ More Data
Impellers courtesy of Chemineer

/ Bar turbine
/ Lightnin R510
/ Np=0.65, Nq=0.36*
Impellers courtesy of P. Csiszar

/ Sawtooth, Disperser
/ Lightnin R500
/ Np=0.45, Nq=0.32*
Impellers courtesy of P. Csiszar
Experimentally derived Np and Nq values coming soon!
* Using the 1/3 power rule to estimate Nq from Np.

Specialty Impellers


/ Anchor
Impellers courtesy of P. Csiszar

This symbol means that a picture of that particular impeller is not yet available.

PARTHA PRATIM DAS

+919433219104