MATERIAL SAFETY DATA SHEETPage 1
From: C A R K E M P R O D U C T S, I N C.
4275 St. Johns Parkway
Sanford, FL 32771
(800) 423-3168
Emergency phone #: (800) 424-9300 CHEMTREC
To comply with OSHA form #174
SECTION 1 – IDENTIFICATION OF PRODUCT
Product Name:ODOR ABSORBER
Product Code:S-84
Synonym or Cross Reference:DEODORIZER
SECTION II – HAZARDOUS INGREDIENTS
Ingredients:CAS No.TLV/PELWGT %
Isopropyl Alcohol67-63-0400ppm / 400ppm50
SECTION III – PHYSICAL DATA
Appearance: Light Yellow LiquidVapor Density;Same as Water
Odor:Pleasant OdorEvaporation Rate:1.6 (BuAc=1)
Specific Gravity0.92Solubility In Water:Complete
Vapor Pressure (mmHg):Same as Water PH:7
Boiling Point:212 F
Melting Point:N/A
SECTION IV – FIRE AND EXPLOSION DATA
Flash Point:87 F (C.O.C.)
Lower Flammable Limit %:N/A
Upper Flammable Limit %:N/A
Fire Extinguishing Media:Carbon Dioxide, Dry Chemical, Foam, Water Fog, Foam.
Special Fire Fighting Procedures:Liquid is soluble in water & is easily diluted.
Unusual Fire and Explosion Hazard:DO NOT cut drum with torch as explosion may result.
SECTION V – HEALTH HAZARD / TOXICOLOGICAL PROPERTIES
Acute Effects
Eyes:Contact with eyes can cause irritation, redness, tearing, blurred vision, and/or swelling.
Skin:Prolonged skin contact may cause irritation.
Inhalation:Inhalation of vapors can cause nasal and respiratory irritation, dizziness, weakness, fatigue, nausea, headache.
Ingestion:May cause headaches & nausea.
Chronic Effects:None
Carcinogenic:Yes _ No _X
Teratogen:Yes _No _X
Mutagen:Yes _No _X
Primary Routes of Exposure: Inhalation, Skin, Ingestion.
F I R S T A I D
Inhalation:If inhaled, remove victim from exposure to well ventilated area. Make him/her comfortably warm, but not hot. Use oxygen or artificialrespiration as required. Consult a physician.
Skin:Flush with water immediately and then wash off with soap and water.
Eyes:For eye contact, flush promptly with excess water for at least fifteen minutes. Consult a physician.
Ingestion:If ingested, do not induce vomiting. Give victim several glasses of water. Call physician immediately.
MATERIAL SAFETY DATA SHEETPage 2
From: C A R K E M P R O D U C T S, I N C.
4275 St. Johns Parkway
Sanford, FL 32771
(800) 423-3168
Emergency phone #: (800) 424-9300 CHEMTREC
Product Name:S-84 ODOR ABSORBER
SECTION VI – REACTIVITY DATA
Stability:Stable
Conditions To Avoid:None
Incompatibility Materials To Avoid:Avoid contact with strong oxidizers.
Hazardous Decomposition Products:None
Hazardous Polymerization:Will not occur.
SECTION VII – SPILL AND DISPOSAL PROCEDURE
Spills, Leak or Release:Wipe up and contain large spill with inert absorbent. Flush with large quantities of water. Keep away from children.
Waste Disposal:Dispose of in accordance with Local, State, and Federal Regulations.
SECTION VIII – PROTECTION INFORMATION
Respiratory Protection:With general room ventilation. Does not require a respirator.
Ventilation:Normal local exhaust.
Protection Gloves:To prevent prolonged exposure, use rubber gloves.
Eye Protection:Safety glasses or goggles with splash guard or side shields.
Other Protective Equip. Wear protective clothing as required to prevent skin contact.
SECTION IX – HANDLING AND STORAGE PRECAUTIONS
Storage and Handling:Store in a dry, cool area from heat & sources of ignition. Keep container closed when not in use. Keep away from Children.
SECTION X – ADDITIONAL INFORMATION
Shipping Information: Please comply with DOT regulations in USA
Hazard Rating:
0= InsignificantHealth2
1= SlightFire3
2= ModerateReactivity0
3= HighPersonal Protection – see section VIII
4= Extreme
Product Code: S-84Prepared on:08/2003
This information in the Material Safety Data Sheet has been compiled from our experience and date presented in various technical publications.
It is the user’s responsibility to determine the suitability of this information for the adoption of the safety precautions s may be necessary.
We reserve the right to revise Material Safety Data Sheets from time to time as new technical information becomes available. The user has the responsibility to contact the company to make sure that the sheet is the latest issue.