/ Transport Services Division
GEOSPATIAL SERVICES
Survey String Identifiers
SEQUENTIAL STRINGS / GR / GuardRail Face *** / PCBI / Irrigation - Control Box / PUPL / Unknown Point (With Level) / LINE MARKING
GU / Gutter / PCCB / Cathodic Cables Box / PUPP / Unknown Point
AB / Bridge Abutment / H / Hedge *** / PCMM / Telecommunications Cable Marker / PVEE / Vent, Sewer / TA / Undefined
B / Building *** / HW / Headwall (Top) / PDHH / Drill Hole / PWPA / Wooden Pole / TB / Solid Line
BB / Bank Bottom / K / Kerb / PECM / ETSA Cable Marker / PWPS / Wooden Pole and Sign / TC / Lane Line 6.0 x 6.0
BC / Concrete Border *** / LA / Ladder / PEMP / Environmental Marker Post / TOPSTONES / TD / Lane Line 9.0 x 3.0
BE / Concrete Barrier Edge / LB / Trackside Location Box (Rail) / PFLL / Floor Level / TF / Pedestrian 0.6 x 0.3
BI / Concrete Barrier Intermediate / LVT / Levee Bank (Top) / PFMP / Fire Plug Marker Post / PDTT / DPTI / TG / Turning 0.6 x 0.6
BP / Telephone Box / N / Natural Surface / PFMR / Fire Plug Marker Reflector / PEXX / ETSA / TH / Stop Line 0.45 wide ***
BR / Bridge Deck / OH / Overhead Wires / PGGG / Grating / PGXX / Gas / TI / Stop Line 0.60 wide ***
BRP / Bridge Piers / QQ / Model Check String / PGII / Nail (GIN) / PSWW / Stormwater / TJ / Give Way 0.45 wide ***
BS / Bus Stop Shelter / RG / Rail (Top Gauge Face) / PGMP / Gas Marker Post / PSXX / Sewer / TK / Give Way 0.60 wide ***
BSE / Bench Seat / RK / Rock Outcrop (Base) / PHOT / Photograph / PTBB / Telecommunications / TL / Continuity 3.0 x 1.0
BT / Bank Top *** / RS / Road Sign or Hoarding *** / PHYY / Hydrant / PUKK / Unknown / TM / Straight Arrow
CC / Centre of Creek / RT / Rail (Top Centre) / PLBB / Litter Bin / PWRW / Reclaimed Water / TN / Left Turn Arrow
CD / Centre of Drain / RW / Retaining Wall / PMBB / Mail Box / PWXX / Water / TO / Right Turn Arrow
CR / Rail Track (Centre Line) / SD / Sand Dune (Base) / PMGG / Gas Meter / PXXX / Railway / TP / Straight/Left Turn Arrows
CT / Centre of Track / SPD / Spoon Drain ***** / PMPB / Pavement Bar / JUNCTION BOXES / TQ / Straight/Right Turn Arrows
DR / Driveway / SU / Sump / PMPP / Metal Pin / TR / Left/Right Turn Arrows
DW / Doorway / SW / Swamp / PMWW / Water Meter / JB / Unknown / TS / U-Turn Arrow
EA / Earth Cable (Rail) / U / Unknown String (Tinable) / PMXX / MARS Marker / JD / DPTI / TT / 45º Left Turn Arrow
EB / Edge of Bitumen / UG / Underside Bridge Girder / PNSS / Natural Surface - Point / JE / ETSA / TU / 45º Right Turn Arrow
EC / Edge of Concrete / UX / Unknown String (Non Tinable) / PPBB / Boundary Peg / JG / Gas / TW / Left/45º Left Turn Arrows
ED / Edge of Drain / V / Veranda / PPEE / Engineering Peg / JR / Stormwater / TX / Right/45º Right Turn Arrows
EF / Edge of Footpath / W / Wall *** / PPFF / Fence Post / JS / Sewer / TY / Straight/Left/Right Turn Arrows
EP / ETSA Pylon / WB / Weighbridge / PPGG / Guide Post / JT / Telecommunications / TZ / Solid & Dashed Barrier Line ***
ER / Edge of Road / WC / Tank / PPSA / Sign Post (One Sided) / JW / Water / T1 / Bicycle
ES / Edge of Shoulder / WE / Well / PPSB / Sign Post (Two Sided) / JX / Railway / T2 / Disabled
ET / Edge of Track / WP / Water Pipe (Above Ground) / PPTM / Parking Ticket Machine / LIGHTS AND GANTRIES / T3 / Pedestrian
EU / Edge of Brick Pavers / WT / Water Trough / PPUU / Petrol Pump / T7 / Double Solid Barrier Line
EW / Edge of Water / WW / WingWalls (Bridge) / PSBB / Signal Box / LT / Top of Sign / T8 / Special Purpose Line 9 x 3
F / Fence / POINT STRINGS / PSKK / Spike / LU / Bottom of Sign / T9 / Edgeline 23 x 1
FL / Flood Level / PSPA / Steel Pole / OR / Lighting Outreach / BOUNDARY MODEL
FP / Fuel Pipe (Above Ground) / PBOL / Bollard / PSSA / Survey Station / PCAM / Camera / CCTV
G / Gate / PBPP / Telephone / PSTA / Stobie Pole / PCOM / Combo Light and Traffic Light / BD / Boundary
GB / Wire Rope Safety Fence / PBSS / Bus Stop Sign / PSUU / Sump - Domestic / PLPO / Lighting Pole / EZ / Easement
GD / Grid / PBXX / Bore / PTAA / Tap / PPLI / Lighting Luminare
GG / Grating / PCAT / Cathodic Protection Post / PTPP / Telecommunications Pillar / PTLL / Traffic Light
Note / ** Indicates that survey code will be used only with additional vegetation requirements 5.12 (b)
*** Indicates that the string shall be run so that the feature is on the right
**** Indicates that the string shall be run from highest to lowest level / TEXT STRINGS WITHIN MODELS
*A All road names and other features
Z codes to be annotated for service type
/ Transport Services Division
GEOSPATIAL SERVICES
Survey String Identifiers
UNDERGROUND SERVICES / TREES AND VEGETATION / TOP OF PIPE
(DIAMETER OF SERVICE mm) / CULVERT STRINGS
(CULVERT SIZE mm) / CULVERT INVERTS
(CULVERT SIZE mm)
DT / DPTI / EV / Edge of Vegetation *** / Z1 / Pipe Bundle Edge (open trench) / C10 / 300 x 150 / PI10 / 300 x 150
EL / ETSA / PSHH / Shrub / ZA / 25mm dia / C11 / 375 x 225 / PI11 / 375 x 225
GA / Gas / PTRT / Spread < 1.5m / ZB / 50mm dia / C12 / 450 x 150 / PI12 / 450 x 150
RX / Railway / PTRU / Undersized Trunk - Tree >2m Tall ** / ZC / 75mm dia / C13 / 450 x 225 / PI13 / 450 x 225
SE / Sewer / PTRS / Spread 1.5m - 3.0m / ZD / 100mm dia / C14 / 450 x 300 / PI14 / 450 x 300
TE / Telecommunications / PTRM / Spread 3.0m - 7.0m / ZE / 125mm dia / C15 / 600 x 225 / PI15 / 600 x 225
US / Unknown Service / PTRL / Spread 7m - 10m / ZF / 150mm dia / C16 / 600 x 300 / PI16 / 600 x 300
WA / Water / PTRX / Spread > 10m / ZG / 175mm dia / C17 / 600 x 450 / PI17 / 600 x 450
WR / Reclaimed Water / PTRZ / Significant Tree / ZH / 200mm dia / C18 / 750 x 300 / PI18 / 750 x 300
DEPTHED SERVICES / RAIL ASSETS / ZI / 225mm dia / C19 / 750 x 450 / PI19 / 750 x 450
ZJ / 250mm dia / C20 / 750 x 600 / PI20 / 750 x 600
PNFD / Depthed Service - Not Found / PAWS / Early Warning system / ZK / 275mm dia / C21 / 900 x 300 / PI21 / 900 x 300
PUDD / DPTI / PEPP / Earth Peg / ZL / 300mm dia / C22 / 900 x 450 / PI22 / 900 x 450
PUEE / ETSA / PIRJ / Insulated Rail Joint / ZM / 375mm dia / C23 / 900 x 600 / PI23 / 900 x 600
PUGG / Gas / PMUS / Signal Mushroom / ZN / 400mm dia / C24 / 900 x 750 / PI24 / 900 x 750
PURR / Railway / PPMO / Point Motor / ZO / 450mm dia / C25 / 1200x 300 / PI25 / 1200x 300
PURW / Reclaimed Water / PPOB / Point of Switchblade / ZP / 525mm dia / C26 / 1200x 450 / PI26 / 1200x 450
PUSS / Sewer / PRMP / Railway Marker Post / ZQ / 550mm dia / C27 / 1200x 600 / PI27 / 1200x 600
PUTT / Telecommunications / PTUU / Tuning Unit / ZR / 600mm dia / C28 / 1200x 900 / PI28 / 1200x 900
PUUP / Stormwater / PVAA / Voice Activation Unit / ZS / 750mm dia / C29 / Undefined / PI29 / Undefined
PUUU / Unknown Depthed Service / PVXT / Rail VX Tip / ZT / 850mm dia / DRAINAGE STRINGS
PIPE SIZE (mm) / PIPE INVERTS
(PIPE DIAMETER mm)
PUWW / Water / PWSS / Whistle Sign / ZU / 900mm dia
PNSU / Depthed Service - Surface Level / ZV / 1000mm dia / D1 / 300 / PI01 / 300
ZW / 1050mm dia / D2 / 375 / PI02 / 375
ZX / 1200mm dia / D3 / 450 / PI03 / 450
ZY / 1500mm dia / D4 / 525 / PI04 / 525
ZZ / 1800mm dia / D5 / 600 / PI05 / 600
D6 / 900 / PI06 / 900
D7 / 1200 / PI07 / 1200
D9 / Undefined / PI09 / Undefined
PIDD / Domestic Outlet
Note / ** Indicates that survey code will be used only with additional vegetation requirements 5.12 (b)
*** Indicates that the string shall be run so that the feature is on the right
**** Indicates that the string shall be run from highest to lowest level / TEXT STRINGS WITHIN MODELS
*A All road names and other features
Z codes to be annotated for service type

K-Net Doc: 7541040 Version No.: 2UNCONTROLLED COPY WHEN PRINTED

Issue Date: 6/05/2015

Doc. Owner: Coordinator Geospatial ServicesPage 1 of 2