2003 ECO Summary
Continuous - 1- of - 18 -
GKE ECO Summary - 2003
Description / Year / Eff. Date / ECO # / ECOReport #
First time this unit has been built in the China Facility.
GLS G2RTR1C 5103007000157
AFFECTED PARTS:GLS -G2RTR1C
DWG NO.:#211054 / 2003 / Jan.07/03 Day 7 / ECO #03-001C / GKE-Jan-03
It is the first time that China facility uses the Canada made shipping box in China Facility.
MOG G2WTW2C 1203009000761
AFFECTED PARTS:BOX-C8 / 2003 / Jan.09/03 Day 9 / ECO #03-002C / GKE-Jan-03
Reworked 220v coolers which were built between Dec.24/02 and Dec.30/02 (total: 136pcs. ), Reason was to change the China made pin out and replace with the Canada pin. The base of pin was too big.
FROM MOG G2WTW2C 1202357051013
TO MOG G2WHW2SC 1202364051853
AFFECTED PARTS:PLC-C88CCrystal Cone-Pin / 2003 / Jan.11/03 Day 11 / ECO #03-003C / GKE-Jan-03
About 500pcs.(coolers) were manufactured by GKE using the Mei Wei Air conditioning equipment modified drier. This drier has a groove around the condenser end so as to limit how much condenser tube can be inserted during manufacturing .
FROM MOG G2WTW2C 1203015001769
TO GLE G2WTW1C 1103027003479
AFFECTED PARTS: REF-C1C Drier / 2003 / Jan.15/03 Day 15 / ECO #03-004C / GKE-Jan-03
The newly modified crystal cone pin (China) is now being used on line in coolers. It is the first time we use China made pin.
GLE G2WTW1C 1103017001998
AFFECTED PARTS:PLC-C88CCrystal Cone-Pin / 2003 / Jan.17/03 Day 17 / ECO #03-005C / GKE-Jan-03
Started wiping the plastic reservoirs with a 2.5% (v/v) vinegar /water solution . This is the same procedure that is being used in Canada. All reservoirs are to be wiped out and plastic reservoirs are to be wiped out upon receiving, during manufacturing and again at final inspection.
GLE G2WTW1C 1103017001969
AFFECTED PARTS:PLC-C134C, PLC-C118,
PLC-C95 / 2003 / Jan.17/03 Day 17 / ECO #03-006C / GKE-Jan-03
Change the dimension 0.145" to 0.131"-0.003". (Also change 2.366" to 2.360"+0.003" on the drawing according to the parts. This change was happened early and reflected on the drawing PLC-C000084H1A this time.)The dimension change from 0.145" to 0.131" was implemented just by injection process. The mold was not changed.
GLE G2WTW1C1103017001998
AFFECTED PARTS:PLC-C000084H1A / 2003 / Jan.17/03 Day 17 / ECO #03-007C / GKE-Jan-03
It is the first time that China facility has used the Canada made drier in GKE. It was discovered that there is a lot of white desiccant / metal filings inside the drier. Production line is to continue to tap this material out onto a table until no powder/ filings is present. China driers have been ordered.
GLE G2WTW1C 1103020002219
AFFECTED PARTS: REF- C1 Drier / 2003 / Jan.20/03Day 20 / ECO #03-008C / GKE-Jan-03
Using CM evaporator until they are finished. We're required to process the same way as CM always did on evaporator, we're following a way as below:
* A bending jig was set up by Sam. Using it specially for the CM evaporator only.
* We do spray some white paint on cracked area that causes from bending.
* A protection tube (clear) is added right below the angle where will be touched with the latch. Doing so will help to prevent the damage of the evaporator during assembly.
MOE F2WTW18C 1103023003054
AFFECTED PARTS:REF-C46Evaporator / 2003 / Jan.23/03Day 23 / ECO #03-009C / GKE-Jan-03
It was the new model cooler (MOE F2RHR18C) that is being produced in GKE. Normally, this model cooler is required to be matched with C-Ring dark granite, drip tray mogul black, faucet black/black and faucet black/red, also it was the first time that the line used those 4 new parts in coolers.
MOE F2RHR18C 5103024003311
AFFECTED PARTS:CLR-C211051,
PLC- C1000172
PLC-C186,
FAU-C20, FAU-C63 / 2003 / Jan.24/03Day 24 / ECO #03-010C / GKE-Jan-03
Started using a torque wrench to tight the baffle stem better instead using torque gun. It would be set at 30lbf.in when working on H/C coolers, and 35lbf.in for C/C as well as a standard to follow.
MOE F2RHR18C 5103024003311
AFFECTED PARTS:AVT 100ATorque Wrench / 2003 / Jan.24/03Day 24 / ECO #03-011C / GKE-Jan-03
Start using the China made drier regularly as the results of 500pcs. tested drier were fine.
GLE G2WTW1C 1103027003480
AFFECTED PARTS:REF-C1C(Drier) / 2003 / Jan.27/03Day 27 / ECO #03-012C / GKE-Jan-03
The CM shipping box were all used up, and went back to use China shipping box.
GLE G2WTW1C 1103028003544
AFFECTED PARTS:BOX-C8C Shipping-Box / 2003 / Jan.28/03Day 28 / ECO #03-013C / GKE-Jan-03
A new label (MOE F2WTW18C) was made up for the mogul , E reservoir ,110v cooler. Label now has either an 8 = 2yr warranty or 9 = 1 year warranty * F = Aquaflo 2 is the new part that we are using in this cooler. As the specific size of the Aquaflo, matching with PLC-C196 and PLC-C197 is required, this is a prevention of air locks.
MOE F2WTW18C 1103022002756
AFFECTED PARTS:Part No11048
PLC-C138C
AquaFlo. 2 / 2003 / Jan.22/03 Day 22 / ECO #03-014C / GKE-Feb-03
This was the last cooler that used the old parts PLC-C136C & 137C, and will use PLC-C196C & PLC-C197C on all model coolers from now on.
GLS G2WTW1C 1103043003975
AFFECTED PARTS:PLC-C196C, PLC-C197C / 2003 / Feb.12/03 Day 43 / ECO #03-015C / GKE-Feb-03
The evaporator gasket now is being used is 3cm shorter than the one we always use before. The total of them is 8,000 pcs. Gasket still covers the cooling/refrigeration area of the evaporator.
GLS G2WTW1C 1103043003981
AFFECTED PARTS:MIS-C49C
Evaporator-Gasket / 2003 / Feb.12/03 Day 43 / ECO #03-016C / GKE-Feb-03
First time that the MOS F2WHW18C unit has been built in the China Facility.
MOS F2WHW18C 1103051801660
AFFECTED PARTS:No. 211059
MOS- F2WHW18C / 2003 / Feb.20/03 Day 51 / ECO #03-017C / GKE-Feb-03
First time the MOS F2WTW18C unit has been built in the China Facility.
MOS F2WTW18C 1103052801886
AFFECTED PARTS:No. 211058,
MOS- F2WTW18C / 2003 / Feb.21/03 Day 52 / ECO #03-018C / GKE-Feb-03
Changed supplier of the screw (FAS-C40C) from Jin-ma to Peng-hui-da.
GLE G2WTW1C 1103050005262
AFFECTED PARTS:FAS-C40C Screw / 2003 / Feb.19/03 Day 50 / ECO #03-019C / GKE-Feb-03
The CM evaporator were all used up, and start using the Shanghai made evaporator from today on
MOE F2WTW18C 1103063802928
AFFECTED PARTS:REF-C46CEvaporator / 2003 / Mar.04/03 Day 63 / ECO #03-020C / GKE-Mar-03
Trial production run of MOE / MOS C/C coolers being built without the support bracket. Coolers are being shipped to Edmonton warehouse for trial run.
FROM MOE F2WTW18C 1103062802797
TO Unknown Yet
AFFECTED PARTS:SMT-C100C
Support-bracket / 2003 / Mar.05/03 Day 64 / ECO #03-021C / GKE-Mar-03
The wire was changed from white to back to black as per the Canadian product. This was also an issue during a UL inspection during the middle of last year.
GLE G2RHR1SC 5103064005548
AFFECTED PARTS: ELE-C58C
WireUsed In-Hot Tank / 2003 / Mar.05/03 Day 64 / ECO #03-022C / GKE-Mar-03
Changed supplier for FAS-C38C screw from Jin-ma to Peng-hui-da.
MOE F2WTW18C 1103066803842
AFFECTED PARTS:FAS-C38CScrew 10x3/8 / 2003 / Mar.08/03 Day 67 / ECO #03-023C / GKE-Mar-03
All of the model MOE / MOS, C/C 110v coolers will now be built without the inclusion of the support bracket. Culligan orders wil still have the stick.
MOE F2WTW18C 1103066803909
AFFECTED PARTS:SMT-C100C / 2003 / Mar.08/03 Day 67 / ECO #03-024C / GKE-Mar-03
The newly modified floater cap is now being used on line in coolers. This new designed floater cap has more holes on it than the old model has. For corresponding the new cap, of course, a coordinated dimension of those screen s.s and filter paper to match with it are required. (the ID of the floater cap is a little too small to fit on the transition cone, but a jig provided by MC helps to enlarge the cap before assembling.)
GLE G2RTR1C 5103070006293
AFFECTED PARTS:Floater-Cap PLC-C103C
MIS-C48C
MIS-C100022C / 2003 / Mar.15/03 Day 74 / ECO #03-025C / GKE-Mar-03
The modified baffle cup has been shortened and has an '' B '' on its bottom side for identification.
GLS G2WTW1C 1103073007391
AFFECTED PARTS: PLC-C197C
Shortened - Baffle Cup / 2003 / Mar.17/03 Day 76 / ECO #03-026C / GKE-Mar-03
Previously rejected driers from CM (ECO # 03-008C) were used online due to a lack of parts from the Chinese supplier. The particles of desiccant are being tapped out of the driers and then purged out with Nitrogen.. This process is used to remove the excess particles from inside of the driers.
MOE F2WTW18C 1103069804298
AFFECTED PARTS: REF-C000001
DRIER (CM) / 2003 / Mar.10/03 Day 69 / ECO #03-027C / GKE-Apr-03
First time that Glacier Cooler Crystal Guard C&C Granite 220v unit (GLR G2RTR2C) has been built in the China facility and the model of H&C Granite 220v cooler is produced as well at the same day.
GLR G2RTR2C 5203098008795
AFFECTED PARTS:Part# 202047
Part# 202048 / 2003 / Apr.08/03 Day 98 / ECO #03-028C / GKE-Apr-03
It is the first time that we use China made baffle disc. They are being used on line in coolers from now on. Its material was changed from HIPS to ABS.
MOE-F2WHW18C 1103092805265
AFFECTED PARTS: PLC-C73CBaffle-disc / 2003 / Apr.02/03 Day 92 / ECO #03-029C / GKE-Apr-03
Magna Dielectric Tester is being used on the production line instead of the Valhalla Tester. The Valhalla is not functioning and will need to be sent out for repair
GLR G2WTW2C 1203100009031
AFFECTED PARTS:Dielectric-tester / 2003 / Apr.10/03 Day 100 / ECO #03-030C / GKE-Apr-03
Removed GKE logo from the pallet sheets and no Chinese characters are to be used on sheet.
MOE F2RTR18C 5103077804922
AFFECTED PARTS:Pallet Sheet / 2003 / Mar.19/03 Day 78 / ECO #03-031C / GKE-Apr-03
Starting on coolermodel"MOE F2WHW18C 1103104806500", all coolers will have the primary ground wire installed separately from the secondary ground wires. The primary ground wire from the power supply will be secured to the bottom plate along with a star washer in the current location. The secondary grounding wires throughout the cooler(to compressor, to hot tank) will be installed along with the same screw as the support bracket. On unit not requiring a stick, the secondary wire will be secured to the bottom plate in a stick mounting hole along with a star washer.
MOE F2WHW18C 1103104806500
AFFECTED PARTS:FAS-C23C, ELE-C15C
ELE-C23C, ELE-C48C / 2003 / Apr.14/03 Day 104 / ECO #03-032C / GKE-Apr-03
First time that this model of cooler has been built in GKE.
GLR G2RTR1C 5103104009267
AFFECTED PARTS:#204019, GLR-G2RTR1C / 2003 / Apr.14/03 Day 104 / ECO #03-033C / GKE-Apr-03
It was the first time that this model of cooler has been built in GKE.
GLE C2WHW1SC 1103107009640
AFFECTED PARTS:Part#211031,
GLE-C2WHW1SC / 2003 / Apr.17/03 Day 107 / ECO #03-034C / GKE-Apr-03
It is the first time that this new model of cooler which is assembled with the ''D'' lid (the completed set of ''D'' lid is included the outer dryguard cover, inner cone, dryguard float ring, filter cap which in color blue, and the crystal cone pin) is being built in GKE. from this unit on, using the single channel crystal cone pin only on all cooler is required .
GLR D2WTW18C 1103111807398
AFFECTED PARTS:Part #211062,
PLC-C100047C
PLC-C100046C,
PLC-C100044C,
PLC-C000088C / 2003 / Apr.21/03 Day 111 / ECO #03-035C / GKE-Apr-03
The new designed model called SIERRA COOLER is being built from now on.
SIR D2LTB2C 8203114010242
AFFECTED PARTS: SIRD2LHB2C,
SIRD2LTB2C / 2003 / Apr.24/03 Day 114 / ECO #03-036C / GKE-Apr-03
Started to build this new designed undersink ICEBERG cooler in GKE. A welding jig provided by MC for rolling and making out the copper evaporator tube which especially for that undersink cooler was set up. (we need two more of this welding jig just in case of getting busier.
ICS P1LFL2C 8203114010531
AFFECTED PARTS: Part# 310001
Evaporator-welding jig / 2003 / Apr.24/03Day 114 / ECO #03-037C / GKE-Apr-03
It is the first time this one tap, POU lid , CT cooler has been built on the line.
AVS P1WFW1C 1103118011139
AFFECTED PARTS:Part# 205015 / 2003 / Apr.28/03 Day 118 / ECO #03-038C / GKE-Apr-03
The model MOG G2WHW2EC has started to be built. It was a new model of cooler that was for the first time equipped with an ETS for H&C unit in GKE. (the letter E after the voltage with a 1or 2 identifies that the cooler is equipped with an ETS)
MOG G2WHW2EC 1203112010080
AFFECTED PARTS:Electronic-Thermostat / 2003 / Apr.22/03 Day 112 / ECO #03-039C / GKE-Apr-03
This is the first unit that was tested by the new purchased Dielectric tester,(serial number 20303425) - Manufacturer is Nanjing Changsheng instrument co., LTD. This tester is currently being used on line now. This meets the CAO that was issued to us by the CSA auditor earlier in the first quarter of this year.
GLR G2WTW2C 1203101009256
AFFECTED PARTS:Dielectric Unit
Model: CS2670A / 2003 / Apr.14/03 Day 104 / ECO #03-040C / GKE-May-03
Started to produce coolers using the single channel pin with the solid head design. Note: differences are also apparent in the ID of the single channel.
GLE G2WTW1C 1103127012099
AFFECTED PARTS:PLC-C88C / 2003 / May.07/03 Day 127 / ECO #03-041C / GKE-May-03
The Unit Serial No's from GLE G2WTW1C 1103128012296 to ICS P1LFL2C 8203129012432 were tested using only the gauge & Amp meter while the PLC tester was not working.
From: GLE G2WTW1C 1103128012296
To: ICS P1LFL2C 8203129012432
AFFECTED PARTS:PLC Tester / 2003 / May.08/03~
May09/03
Day 128~129 / ECO #03-042C / GKE-May-03
The wiring of the cold control on the Iceberg cooler has been changed from running beneath the reservoir where it was attached to a spacer, to running beside the reservoir & around and attached to the condenser.
The wires are attached to the condenser with a cable tie, in a location whereas the wires are not accessible from the outside of the cooler.
ICS P1LFL2C 8203128012402
AFFECTED PARTS:ELE-C24C / 2003 / May.08/03 Day 128 / ECO #03-043C / GKE-May-03
First time that the China made Grommet has been used in coolers from this Supplier.
GLR D2RTR2C 5203149019209
AFFECTED PARTS:SIL-C25CGrommet / 2003 / May.29/03 Day 149 / ECO #03-044C / GKE-May-03
Started using the new Top-plate which has two more holes added ( total has four holes ) from this unit on.
MOE G2WTW1C 1103140015535
AFFECTED PARTS:SMT-C000102CTop Plate / 2003 / May.20/03 Day 140 / ECO #03-045C / GKE-May-03
Started using the newly designed Filter Screen, Plastic in cooler instead of the filter S.S.
GLE G2WTW1C 1103143017138
AFFECTED PARTS:PLC-C100068c
Filter Screen-Plastic / 2003 / May.23/03 Day 143 / ECO #03-046C / GKE-May-03
It is the first cooler that go through the Valhalla Dielectric Tester which just has been brought back from repairs.
MOG G2WTW2C 1203177024195
AFFECTED PARTS:Valhalla -Dielectric-tester / 2003 / Jun.26/03 Day 177 / ECO #03-047C / GKE-June-03
A plastic tie will be added around the shrink tube of the power switch on all H&C coolers from this unit on.
MOG G2WHW2SC 1203177024222
AFFECTED PARTS:MIS-C2Plastic Ties / 2003 / Jun.26/03 Day 177 / ECO #03-048C / GKE-June-03
White Top-insulation will be supplied by China and not by Canada any longer.
GLR D2RTR2C 5203149019180
AFFECTED PARTS:REF-C22C Top-Insulation (white) / 2003 / May.29/03 Day 149 / ECO #03-049C / GKE-June-03
The White Insulation Res. will be supplied by China and not by Canada any longer.
GLR G2WHW2SC 1203164022659
AFFECTED PARTS:REF-C22C Insulation Res.(white) / 2003 / Jun.13/03 Day 164 / ECO #03-050C / GKE-June-03
It is the first new model of cooler which is Sierra body B, Dry Guard H& C , Light grey, 220V cooler. Two of this type had been built for sample.
SIE D2LHB2C 8203168023506
AFFECTED PARTS:Part# 300021 / 2003 / Jun.17/03 Day 168 / ECO #03-051C / GKE-June-03
This is one of the two sample coolers was built on line for sending out as a sample. This is a new model of cooler has been built in GKE.
MOE G2WHW2SC 1203168023504
AFFECTED PARTS:Part# 204021
MOE -G2WHW2SC / 2003 / Jun.17/03 Day 168 / ECO #03-052C / GKE-June-03
It was the first time that model " GLR D2WTW2C " had been built.
GLR D2WTW2C 1203162022183
AFFECTED PARTS:Part# 202049 / 2003 / Jun.11/03 Day 162 / ECO #03-053C / GKE-June-03
It is the first unit that was built as GLACIER COOLER DRYGUARD H&C WHITE 220V(GLR D2WHW2SC).
GLR D2WHW2SC 1203170024038
AFFECTED PARTS:Part# 202050 / 2003 / Jun.19/03 Day 170 / ECO #03-054C / GKE-June-03
We have stopped making coolers with the Tecumseh open contact white relay & cutout, instead of them, the open contact relay & cutout has been replaced with the old black cover style
MOG D2WHW2SC 1203189027579
AFFECTED PARTS:RelayCutout (Tecumseh) / 2003 / Jul.08/03 Day 189 / ECO #03-055C / GKE-July-03
It is a new model of cooler that is being built for the first time in GKE. (ALP Drip-tray to be matched within as BOM)
LE G2WHW1SC 1103190027820
AFFECTED PARTS:Part# 211067 PLC-C85C
PLC-C153C / 2003 / Jul.09/03 Day 190 / ECO #03-056C / GKE-July-03
This is the first cooler that we built for new model MOG D2WHW2SC. Also, the serial # of the first cooler for the Mogul body, Dryguard Lid, 220v C&C White is: 1203189027300.
MOG D2WHW2SC 1203189027290
AFFECTED PARTS:Part# 211071 &
Part#211070 / 2003 / Jul.08/03 Day 189 / ECO #03-057C / GKE-July-03
Has the logo of UL certified added on the label for all the 110v Sierra Coolers from this unit on.
SIE D2LHB1C 8103190027596
Label of 110v-Sierra Cooler / 2003 / Jul.09/03 Day 190 / ECO #03-058C / GKE-July-03
From this unit on, we are using the coiled copper-evaporator (6 wraps) on all the 110v Mogul "E'' reservoir coolers instead of using the painted-evaporator. For installing the reservoir and positioning the copper evaporator, a custom made jig was set up. This was also put into use since the first cooler mentioned above at the station where between station#20 and station#21.
MOE F2WTW18C 1103197811465
AFFECTED PARTS: REF-C100010
Copper-Evaporator
Installation Jig of
Copper-evaporator / 2003 / Jul.16/03 Day 197 / ECO #03-059C / GKE-July-03
Changed supplier who cuts the Nomex-paper from Rong-wei to Xin-wei.
MOG D2WHW2SC 1203192028534
AFFECTED PARTS:MIS-C41CNomex-paper / 2003 / Jul.11/03 Day 192 / ECO #03-060C / GKE-July-03
Updates to the existing CSA listing LR103068-7 (Stand up coolers) included things like the hot tank/internal heater, copper tubing evaporator, added Alpha Heaters as an alter heater band, and changed the nomenclature to reflect the inclusion of the possible added characters that reflect the warranty years. / 2003 / Jul22,/ 03 Day 205 / ECO #03-061C / GKE-July-03
A Special Shipment, No. #UK98 to NORFOLK, was sent on the date of Jun.19/03. We started to make Dryguard assemblies which did not include the baffle stem and Baffle-cups (SUB-C1000013C).
AFFECTED PARTS:SUB-C100013 / 2003 / Jun.17/03 Day170 / ECO #03-062C / GKE-July-03
This was the first time that we were assembling the SUB-C100002 in GKE, and they were prepaired for the Shipment No.7810 to OHIO on the date of May.19,2003. ( as the BOM required upon that time, those assemblies were built with Baffle-cups but did not include the Baffle-stem.)
AFFECTED PARTS:SUB-C100002 / 2003 / May 15/03 Day 135 / ECO #03-063C / GKE-July-03
Total of 245pcs were made that included the new Plastic Pin Tool and logo sticker on its top, The process is done by the line workers. This handy tool will make it easier for our customers when it comes to cleaning and/or changing out the pin when required.
AFFECTED PARTS:Plastic Pin -Tool &Sticker / 2003 / Jul.25/03 Day 208 / ECO #03-064C / GKE-July-03