PinPoint

PFD-30X Operator’s Manual

Basic Operations

Voltage adjument: Turn on the VOLT knob to change voltage/vibration value. (right side of the display: “V” light)

Frequency adjument: Turn on the FREQ/SET knob to change frequency. (right side of the display: ”Hz” light)

Functions (For technical person operation)

Enter> Press the FREQ/SET knob 2 seconds, show “ End” on the display. (printed L no this function)

AdjustmentTurning the knob to select the function code then press it. (abbreviated codes are as follows)

Leave Press the knob again, show “End” on the display. The numeric will be saved automatically.

Abbreviation Code List :

Item / Abrrv. / Function / Range / Default / Note
End / Leave and back / Ending
01: / On.d / ON Delay timing / 0~25 sec. / 0.0 sec. / Delay stop timing, RUN led orange light on
02: / OFF.d / OFF Delay timing / 0~25 sec. / 0.0 sec. / Delay start timing, RUN led green light on
03: / InV.1 / PF Input control INV./non-INV. / No/Yes / No / PF,outside control “ON” , choose start or stop
04: / On.S / ON SOFT soft start timing / 0~10 sec. / 0.8 sec. / Curve modify, accelerate soft start function
05: / OFF.S / OFF SOFT soft stop timing / 0~2 sec. / 0.2 sec. / Curve modify, decelerate soft stop function
6H: / HI.F / Frequency maximum / 40~400Hz / 120Hz / Limited maximum frequency
6L: / LO.F / Frequencyminimum / 40~400Hz / 45Hz / Limited minimum frequency
07: / HI.U / Output voltage maximum / 0~240V / 220V / Limited maximum voltage
08: / LO.U / Output voltage minimum / 0~240V / 0V / Limited minimum voltage
09: / FUSE / Circuit breakers / 1,2,… / Nominal
Current / Protect coil to avoid burning out
13: / InV.2 / STOP Input control INV./non-INV. / No/Yes / No / STOP, Outside control “ON”, choose start or stop
14: / OUT.1 / Outside 1 output control
invertering/non-invertering / No/Yes / No / Hopper or outside control ,choose invertering/non-invertering
15: / OUT.2 / Outside 2 airflush control invertering/non-invertering / No/Yes / No / Airflush or AC output control, choose invertering/non-invertering
16: / DCL / Vibration coil DC output position / 0,1 / Normal=0 / Enhances the vibration coil DC position, experiencedperson adjustment
17: / INFO / Display message / N/A / N/A / Display version or fax number
18: / ACIN / Power source limited condition / 110/220/ALL / ALL / Power source use AC110V, AC220V or both
19: / STAR / Power supply start condition / No/Yes / Yes / When power start again whether back to previous power failure condition or not
20: / dISP / Adjust the display brightness / 1~8 / 2 / Depends on working environment
-- : / ---- / Separation / N/A / N/A / Separation
99: / FUNC / Display control function / No/Yes / Yes / Display function 03: below display or not
00: / REST / RESET / No/Yes / No / Restore the defaultsetting

Other Special Functions: 1. Full airflush control 2. High/Low Range Control 3. Sensor dual input series control

4. 0~10V/4~20mA remote control 5. Two segments voltage control 6. abnormal message output

Connect Methods:

Do not disconnect/reconnect output to stop controlling; power input/output is black/white wire, ground wire is green one.

Conntect with 16mm metalconnector: (NPN output type)

  1. Optical fiber, detection sensor,photoelectric sensor: 1st pin: “+V” brown color (+24V voltage) , 2nd pin: “Out ” black color, 3rd pin: “Gnd “blue color.
  2. +12VDC or +24VDC voltage contact: 3rd pin no contact (not connected), 1st pin(+V), 2nd pin(-V), contact outside part which has voltage output control.
  3. Regular switch, Relay No/Nc(including PLC) contact or non voltage contact:

1st pin: not connected, 2nd and 3rd pin: contact switch

  1. Output type of transister PLC: 1st pin: not connected, 2nd pin: output (transistor C.), 3rd pin: Gnd (transistor E.).
  2. 2 pin metalconnector: 1st pin is the 2nd pin of 3 pin connector, 2nd pin is the 3rd pin of 3 pin connector.

Model Descriptions

PFD-30 P

Output Current/Outside Control nil:3A P:4A H:6A U:10A 3:/3P:380~440V

Products Name A: photoelectric amplifier E:0~10V control L:normal

* Note: AC Control=AC 220V solenoid valve control output.

DC Control=DC 24V solenoid valve ( max. 3 W) control output.

AbnormalDisplays

-OC-= Over Current, OH= Overheating, SH= Output short circuit or inside short circuit, HI= Over Voltage,

CAP=Change main capacitor, OP= Over Power

OC, HI, OP press POWER button; OH, SH press both FREQ and POWER button to restore the controller.

Standard Specifications

Model PFD-30X / PFD-30L / PFD-30 / PFD-30P / PFD-30C / PFD-30H / PFD-30U / PFD-303/C/P
Output / Output Current (A) / 3A / 4A / 5A / 6A / 10A / 3.0/2.5/4.0A
Max. Output Voltage (V) / Input Power Volatge 0.9 times
Output Freq. Range (Hz) / 45~180Hz / 40Hz~400Hz
Input / AC Singal Phase (V) / 110VAC/220VAC / 380V/480VAC
AC Power Frequency (Hz) / 50Hz/60Hz/±5%
Allowable VoltageRange (V) / 90~132VAC/180~264VAC / 328V~528VAC
Operating Features / Constant Voltage Output / Output Frequency / Voltage, Manual Set Up
Output Control / Sine Wave, PWM High Frequency Carrier Way
Soft Start/Stop / Fix / Curve Type, Ajustable Speed
Freq. Accuracy/Resolation(Hz) / 0.02%/0.5%
Voltage Accuracy/Resolation(V) / 5%/1VAC / 5%/2VAC
Outside Control Functions / Outside Control Loading / Max. 3W, Max. Current 125mA/+24VDC
Start / Stop Control / Inside
High/Low Speed 2 Sect. Control / Nil / Extra
ON/OFF DELAY Control / Nil / Inside
Inside
AC Relay OutputAir Flush Control / Extra
PenetratingTypePhotoelectricity Induction Control / Nil / Extra
Isolate Type Input Conrol / 1 Set / 1 Set Inside, 1 Set Extra
Outside 1~10V/4~20mA Control / Nil / Extra
+24V DC SSR Output Control / Nil / Extra
tra
Temperature Range / 0~40℃(No Condensation and No Frozen )
Hygro Range / Below 90% RH
Standby Power Loss / 3W (220VAC) / 5W(380VAC)
Cooling Method / Natural Wind / Natural/Aluminum Sheet Wind / Natural Wind
Protect Functions / Over Voltage, Current, Power, Temperature, Low Voltage, Output Short Circuit, Power FUSE, Main Capacitor Lifetime
Weight (including wires ) / 0.95Kg / 1.5Kg / 2.23Kg / 0.95/1.5Kg
Dimension / 170.0(L)x63.5(W)x85.5(H)mm
400(D) mm / 170.0(L)x126.3(W)x85.5(H)mm

Note: 1.This controller is no voltage increased range enlargement, so the max. output voltage is around input power

volatge 0.9 times. 2.Switch frequency or power button after 5 seconds, system saves data automatically. 3.The output current may connect with DC electric instrument or DC clamp meter for interpretation.

Please kindly be informed that this manual may be updated if necessary.