EQUIPMENT CHECKLISTS

Respiratory Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Respirator, half-mask / Silicone, cradle headband, NIOSH/MSHA approved (assorted mask sizes to properly fit individual)
Respirator, full-face / Silicone, strap harness w/roller buckles, scratch-resistant polycarbonate coated lens, NIOSH/MSHA approved (assorted mask sizes to properly fit individual)
Respirator, full-face,
air-purifying, powered / Continuous flow air purifying, air pulled through filters, intrinsically safe belt-mounted blower, positive face pressure, inhalation check valve, scratch-resistant lens, NiCad battery pack, charger, NIOSH/MSHA
approved (assorted mask sizes to properly fit individual)
Breathing apparatus,
self-contained (SCBA) / 30 min service life @ 2216 psi (low pressure), quick fill, cylinder. Compliance: NIOSH/MSHA approval no. TC-13F-138, USCG approval no. 160.011/72/0, ANSI/NFPA standard (assorted mask sizes to properly fit individuals)
Supplied air respirator system w/egress bottle / Full-face mask, mask-mounted regulator, 300' neoprene air supply hose, connects to external air supply, inlet air supply of 60-125 psi, 5-min egress bottle for emergency exit, NIOSH/MSHA approved. (assorted mask sizes to properly fit individuals)
Respirator hood,
emergency escape / 5-min service life @ 2216 psi w/polyurethane hood, refill hose w/adapter, storage case, NIOSH/MSHA approval no. TC-13F-179
Air cylinders,
replacement, 30-min / Quick-fill cylinder, 2216 psi. Compliance: NIOSH/MSHA approval no. TC-13F-138, USCG approval no. 160.011/72/0, ANSI/NFPA standard
Respirator storage bags / Reusable, 12” x 15” transparent bags, zip lock closure
Respirator wipe pad / Alcohol-free, pkg. of 100
Fit test kit,
qualitative / Hood, collar assembly, nebulizers (for initial sensitivity and fit testing), two sets of replacement nebulizer inserts, fit test solution and sensitivity test solution. (Saccharin, Bitrex® or isoamyl acetate)
Fit test system,
quantitative / PortaCount® Plus w/ N95-Companion, fit test SCBA respirator facepieces and verifies sizing and fit. Fit test N95 disposable respirator masks.
Respirator cartridges & filters / For organic vapor/acid gas
Respirator cartridges & filters / For ammonia gas
Respirator cartridges & filters / HEPA
Air compressor / Grade D, breathing, 3000 psi

ATEEC 2010 (www.ateec.org) Respiratory Equipment Page 1 of 10

EQUIPMENT CHECKLISTS

Personal Protective Equipment (PPE)

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Protective suit, vapor, Level A / Total encapsulation, front/rear opening, gas-tight, multi-film shield, ASTM F 1001 standards (assorted sizes recommended)
Protective suit, splash, Level B / Fully encapsulating, front/rear opening (assorted sizes recommended)
Coverall, protective suit, splash, Level B / Total body coverall, Tychem 9400, w/hood (assorted sizes recommended)
Coverall, QC / Tyvek, drawstring hood, zipper closure, elastic wrist & attached booties (assorted sizes recommended)
Coverall, total body / SARANEX, 23P, drawstring hood, zipper closure, elastic wrists & ankles (assorted sizes recommended)
Coverall, total body / Tyvek, elastic cuffs on wrist & ankles, zipper closure (assorted sizes recommended)
Coverall chemical suit, 3-pc, total body / PVC blend/polyester acid suit, attached hood, tapered sleeves, 11.5 oz./sq. yd. (assorted sizes recommended)
Rain suit, 3-pc, total body / 0.20-mm PVC, adjustable suspenders, take-ups at wrists, ankles, waist, 6.5 oz.
Training suit, hazmat / Tyvek, not for use in chemical environments (assorted sizes recommended)
Boots, steel toe / Urethane, 16” high, sizes 6-15
Overboots / Latex, sizes 6-15
Hard hat / 13-oz. high density polyethylene, ratchet suspension. Compliance: ANSI Z89.1-1986; Class A, B, & C; SEI certified (assorted colors)
Hard hat w/face shield, adapter kit / Slot adapter, visor bracket, polycarbonate window. Compliance: ANSI Z89.1-1986; Class A, B, & C; SEI certified
Personal flotation device / Highly visible, non-metallic hardware, Type III/IV. USCG App. #160.053/97/0
Hip boots / See catalogs
Safety glasses / ANSI Z87.1-2003 certified
Safety goggles / Chemical & splash resistant, ANSI Z87.1-2003 certified
Gloves, lined / Cotton liner preferred (polyester acceptable), (assorted sizes)
Gloves, unlined / Nitrile, 12-in. (assorted sizes)
Gloves / Neoprene, 12-in. (assorted sizes)
Gloves, disposable / Latex (assorted sizes)
Gloves, work, leather / Cowhide (assorted sizes)
Ear plugs, disposable / Hearing protection, 25db NRR or greater
Duct tape / Closure of seams, improve stay and fit.

ATEEC 2010 (www.ateec.org) Personal Protective Equipment (PPE) Page 2 of 10

EQUIPMENT CHECKLISTS

Safety Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Signs, hazmat / DOT compliant, NFPA 704 diamond codes
Eye wash/drench hose, portable / 10-gal., type 304 stainless tank, 8’ flex coil hose (25”x12-1/4 ” OD), water treatment additive, eye wash flow 0.4 gpm, drench hose 0.4 gpm. Compliance: ANSI Z358.1-1990
Eye wash station / Saline bottles, double bottles, 32 oz. bottles, buffered, isotonic, pH 7.2, antibacteriostat. Compliance ANSI Z358.1-1990
First aid kit / Weatherproof, industrial, 25 person
Bio response kit / For bloodborne pathogens
Burn kit, emergency / Burn spray, dressings, bandages, gauze, adhesive tape
Trauma kit, EMT / First response trauma kit, industrial, inhalants, bandages, stethoscope, cold packs, EMT shears, gauze, normal saline, penlights, rescue blanket, surgipad, thermometer, tourniquet, water gel burn dressings
Sphygmomanometer / For pre-suit up blood pressure check
Watch w/second hand / For pre-suit up pulse check
Oxygen inhalator, emergency / 15-min unit, face mask, regulator
Fire extinguisher / ABC, 10#
Fire extinguisher / CO@, 15#
Fire extinguisher / AFFF, 2.5 gal.
Lockout/tagout kit / Locks, valve covers, ball valve lockouts, padlocks, valve covers, large plug lock, small plug lock, lockout checklists, hasps, laminated tags, danger magnetic signs, cable ties

ATEEC 2010 (www.ateec.org) Safety Equipment Page 3 of 10

EQUIPMENT CHECKLISTS

Tools

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Tool kit, non-sparking / Box wrenches (5/16”x3/8”, 7/16”x1/2”, 9/16”x5/8”, 3/4”x7/8”), 7-1/2” Phillips screwdriver, 9-3/4” standard screwdriver, 10” adjustable wrench, 8” slip joint pliers,
9-1/2” groove joint pliers, 3-1/8” utility knife, 14” pipe wrench, 3”x8” handle brush, 12” scraper w/ 1-7/8” blade, non-sparking beryllium
Shovel, square point / Non-sparking, polypropylene
Shovel, #2 rounded point / Non-sparking, polypropylene
Shovel, scoop / Aluminum
Drum truck / Steel frame, single handle, 8”x1-5/8” Molden tires, 700-lb. capacity
Drum cradle / Steel, 2-1/2” dia. Non-sparking polyolefin outboard wheels, 600-lb. load capacity
Drum deheader / Manual, forged steel, blades able to be re-sharpened
Manhole cover pick / Crowbar-type tool used to life and remove manhole covers
Push broom / Floor, 18”
Straw broom / Standard
Mop & mop bucket / w/pressure wringer
Squeegee / Floor, 24”
Hose / Heavy-duty, garden, 5/8” ID, 50-ft. sections
Flashlight / Spare bulbs & batteries
Voltage meter, AC/DC / Intrinsically safe, digital readout, flexible connecting probes

ATEEC 2010 (www.ateec.org) Tools Page 4 of 10

EQUIPMENT CHECKLISTS

Spill Control Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Drum & tank repair kits / Stopper plug kit, ball plug kit, sheet metal screw kit, duct tape, barricade tape, dower/stake set, t-bolt patches, epoxy, putt, 8”x12” foam patch w/bolts, 12”x29” rubber patch, 8”x12” polyethylene/rubber patch & clamp w/synthetic strap, non-sparking tool kit
Spill kit / Sorbent pillows, 8” mini booms, pads, poly liner, DOT approval no. DOT E10102
Spill control station, mercury / 500 gm of Hg absorb., 9 Hg sponges, recovery bags, Hg vacuum, gloves, wash bottle
Sorbent rolls & pillows, chemical / Petroleum
Sorbent rolls & pillows, chemical / Universal
Sorbent booms / Petroleum
Sorbent booms / Universal
Sorbent gel / Universal
Sorbent, activated carbon / 50-lb. bags
Baking soda / Large boxes
Citric acid / 50-lb. bags
Spill drain covers / Elastomeric, 1/2” thick, 24”x24”
Salvage drum / Steel; 15-, 30-, 55-, 85-gal.; pre-labeled W; 12-gauge bolt rings, rubber gaskets, epoxy lining: DOT approval no. DOT E6787
Over pack drum / Polyethylene, specs: UN1H2/X295/S, DOT 49 CFR 173.3©, UHN1H2/Y318/S
Liquid transfer kit / For steel containers, bonding & grounding kit, hand pump, hoses and drum plug fittings
Clay pellets / Bentonite

ATEEC 2010 (www.ateec.org) Spill Control Equipment Page 5 of 10

EQUIPMENT CHECKLISTS

Monitoring Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Detector tube kits w/pump / W/detector tubes:
·  Acetone (100-1000 ppm)
·  Ammonia (2-500 ppm)
·  Benzene (5-50 ppm)
·  Carbon dioxide (100-3000 ppm)
·  Carbon monoxide (10-8000 ppm)
·  Chlorine (50-500 ppm)
·  Hydrogen chloride (1-30 ppm)
·  Hydrogen sulfide (1-200 ppm)
·  Petroleum hydrocarbons (100-2500 ppm)
Hazmat kit / ·  Portable hazardous gas detector
·  Hand pump
·  Detector tubes
·  Matrix chart
·  3-m extension hose
·  Tool kit
·  Spare parts
Confined space monitor,
4-gas / For oxygen, LEL, hydrogen sulfide, carbon monoxide, STEL & TWA calculated monitor, charging power supply, 10’ hose, carrying case. Safe for Class 1; Division 1; Groups A, B, B, & D specifications
Hazmat unknowns kit / Identification of unknown chemicals (HazTech Systems Inc.)
Meter, sound level / Standard
Dosimeter, personal / Standard
Radon sampling canister / Tests up to 2000 sq. ft.
Meter, combustible gas / Range of 0-100% LEL, operating temp 0E-120E F, 3’ hose, 10” probe with filter, batteries, charger, carrying case, calibration kits
Monitor, 3 or 4 gas / Portable
Monitor, radiation alert / Portable; detects alpha, beta, gamma, x-rays in 0-50 mR/hr range
Monitor, PID gas / Photo ionization detector:
·  0.1-2000 ppm range
·  built-in data-logger
·  10.6 eV lamp
·  calibration kit carrying case,
·  PC software.
Compliance: UL listed; Class 1; Division 2; Groups A, B, C, & D
Air velocity meter / Portable
Air sample pump / Portable
Cyclone assembly / For respiratory contaminants
pH paper kit / Large strip
GPS, hand-held / Global Positioning System
Thermometer, digital / For ambient air temperature

ATEEC 2010 (www.ateec.org) Monitoring Equipment Page 7 of 10

EQUIPMENT CHECKLISTS

Decontamination Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Decon kit / ·  3-gal. hand pump sprayer
·  Vinyl inflatable pools (10” high x 49” dia.) OR hard molded plastic tubs (large enough for a person to stand in)
·  Wash brushes
·  AquaLockit
·  50’ hose w/fittings
·  3”x150’ lay-flat tubing w/hardware
·  10’x30’ 6-mil. Sheeting
·  12V DC air pump compressor
·  85-gal. DOT-approved overpack
·  Hazmat labels & decon solutions (for solvents, PCBs, pesticides, oils/greases, caustics, radioactive waste)
Decon shower / 23-oz. vinyl-coated nylon liner, steel framework, 6’ high x 4’ wide x 4’ deep
Scissors / Standard
Buckets / Standard 5-fal.
Brushes / Various standard types (e.g., toilet, bottle, etc.)
Hazmat storage bags / 6 mil., 38”x 65”

Site Control Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Decon rope & barricade tape kit / Webbed barricade tape, 7-mil. Woven high-density polyethylene, 3”x500’ black messages
·  CAUTION DO NOT ENTER,
·  CAUTION HAZARDOUS MATERIAL,
·  DANGER,
·  WARNING RESTRICTED AREA
Field glasses (binoculars) / Water-resistant, 7x35mm
Radios / 2-way, mobile, battery operated, field operational
Cellular phone / Standard
Camera w/film / Standard
Tape measure / 100 ft.
Barricades / For cordoning off site
Traffic cones / For cordoning off site
Work vests / High-visibility

ATEEC 2010 (www.ateec.org) Decontamination and Site Control Equipment Page 8 of 10

EQUIPMENT CHECKLISTS

Sampling Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Chemical:
Drum thief, glass / 200 ml.
COLIWASA / Polypropylene, 40”
Sampler, E-Z glass drum bottle / Polypropylene, 43-1/2”, 125 mL borosilicate glass bottle w/Teflon-lined cap
Sampler, tank / Dipstick, 70” polypropylene 12’, 32-oz. bottle, stainless steel pole, polypropylene head w/6’ extension, safety-coated bottle
Sample jars / Check. w/local analytical lab for recommended containers
Sample fixatives / See catalogs
Soil:
Auger kit, soil sampler / ·  3” dia. barrel, general purpose auger
·  Clay auger
·  Sand auger
·  Mud auger
·  Two 34”-auger extensions
·  Driveable auger handgrip
·  Mallet
·  Auger adapter
·  Zero contamination tube
Brass liners / For soil sampler
Scoops / Stainless steel, 2- to 12-oz. set
Bowl or pail / Stainless steel
Sample jars / Check. w/local analytical lab for recommended containers
Water:
Well bailer / Disposable Teflon or polyethylene, various sizes
Depth sounder, digital / Alternatives: depth recorder w/tape & sensor (aka. water level meter) OR oil-water interface probe
Water sampler, remote / For well samples
Alternative: bailer
Dipper / Telescopic handle
Sample jars / Check. w/local analytical lab for recommended containers
pH meter / Standard
Refractometer / Standard
Dissolved oxygen meter / Standard
Conductivity meter / Standard
Thermometer / Alternative: temperature meter
Dredge / Standard
Plankton net / For biological sampling
Secchi disc / Standard
Air:
Pump, air sample / Standard
Filters, air sample / Standard
Tubes, sample collection / Standard
Sample jars / Check. w/local analytical lab for recommended containers

ATEEC 2010 (www.ateec.org) Sampling Equipment Page 9 of 10

EQUIPMENT CHECKLISTS

General Equipment

Item / Description / NA (Not Applicable) / Need It (quantity) / Have It (quantity)
Graphing calculator / TI 82 or 83 scientific
Maps / ·  Topographic maps (e.g., civil engineering contour maps)
·  U.S. Geographic Survey quad maps
Storage / Various, some locking, including flammables storage
Universal Lab Interface (ULI) / CBL data collection software
Software for ULI (e.g., Logger Pro) / Graph Link software
Sampling probes for applicable activity:
·  temperature
·  pH
·  dissolved oxygen
·  nitrates (ion selective adapter needed)
·  conductivity
·  radiation
·  carbon dioxide / ·  TI-CBP system (interfaces between sensors/probes and calculator)
·  DIN adapters (for using microcomputer probes on calculators)

ATEEC 2010 (www.ateec.org) General Equipment Page 10 of 10